Comparison of 980-nm diode laser and electrolytic lesions in rat brain by SDS-PAGE and CD68

Sıçan beyninde yapılan 980-nm diyot lazer ve elektrolitik lezyonlarının SDS-PAGE ve CD68 ile karşılaştırılması

  1. Tez No: 139060
  2. Yazar: ÖZGÜNCEM BOZKULAK
  3. Danışmanlar: YRD. DOÇ. DR. MURAT GÜLSOY
  4. Tez Türü: Yüksek Lisans
  5. Konular: Tıbbi Biyoloji, Medical Biology
  6. Anahtar Kelimeler: CD68, 980-nm diyot laser, elektrolitik lezyon, SDS-PAGE, CD68, 980-nm diode laser, electrolytic lesion, SDS-PAGE
  7. Yıl: 2003
  8. Dil: İngilizce
  9. Üniversite: Boğaziçi Üniversitesi
  10. Enstitü: Biyo-Medikal Mühendislik Enstitüsü
  11. Ana Bilim Dalı: Biyomedikal Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 94

Özet

SIÇAN BEYNİNDE YAPILAN 980-nm DIYOT LASER ve ELEKTROLİTİK LEZYONLARININ SDS-PAGE ve CD68 ile KARŞILAŞTIRILMASI ÖZET Beyin ve sinir hastalıkları cerrahisinde tümör ablasyonlannda kullanılan birçok teknik vardır, laserler bunlar arasında en yeni ve etkili onarıdır. Bu tez çalışmasında geleneksel olarak kullanılan elektocerrahi ünitesi ve yeni cerrahi 980-nm diyot laser adlı iki farklı cerrahi cihazın sıçan beynindeki etkileri karşılaştırılmaya çalışılmıştır. Bu tezde Wistar cinsi sıçan beyninde 980-nm diyot laser (2W/2s) ve elektrocerrahi cihazları (1.5mA/20s) ile yapılan haraplamalann boyutlarını analiz edebilmek için ısıl olarak etkilenmiş olan protein miktarları steryotaksik beyincerrahisinden sonra sodyum dodesil sülfat polyakrilamid gel elektroforez (SDS-PAGE) yöntemi ile incelenmiştir. Her iki lezyonlamamn beyin yarım kürelerinin toplam protein miktarı üzerindeki etkisi ve lezyon alanım çevreleyen ısıl olarak etkilenmiş örnekler incelenmiştir. Çiftaraflı laser ve elektrolitik lezyon uygulamaları sonrası immunohistokimyasal boyamalarda CD68 işaretleyleyicisi kullanılmıştır. Her iki lezyondaki ısıl olarak etkilenmiş bölgelerin yapı ve boyutları belirlenmiş ve lezyon alanındaki makrofaj miktarları karşılaştınlmıştır. SDS-PAGE ile her iki lezyonun deney sonrasi etkileri benzer bulunmuştur. Elektrolitik lezyonun yarattığı ısıl etki laser lezyondan yaklaşık %160 daha fazladır. 7 günlük grubundaki deneklerde, elektrolitik lezyonlarda ki makrofaj/mikroglia miktarı laser lezyonlannınkinden yaklaşık %60 daha fazladır. Laser lezyonu yapılmış deneklerin hiçbirinde karbonizasyona rastlanmamıştır. Sonuç olarak 980-nm diyot laserin (2W/2s), sinir cerrahisinde kullanılmak üzere elektocerrahi ünitesine (1.5mA/20s) bir alternatif olabileceğini bulunmuştur.

Özet (Çeviri)

IV COMPARISON of 980-nm DIODE LASER and ELECTROLYTIC LESIONS in RAT BRAIN BY SDS-PAGE and CD68 ABSTRACT There are several techniques used for neurosurgical tumor ablations; lasers are the newest and most effective of all to apply on brain tissue. This thesis study aims to compare the after-effects of two different surgical tools, namely, the established electrosurgical unit and relatively novel surgical 980-nm diode laser on rat brain tissue. In this thesis, in order to analyze the extent of damage created by 980-nm diode laser (2W/2sec) and electrosurgical unit (1.5mA/20sec) in Wistar rat brain tissue, the thermally affected protein content after stereotaxic neurosurgery was investigated by Sodium Dodecyl Sulphate Polyacrylamide Gel Electrophoresis (SDS-PAGE). The effects of both types of lesions on the whole brain and on the thermally altered nearby tissues were investigated. In order to observe the recovery period of brain tissue after bilateral laser induced and electrosurgical lesions, CD68 specific marker was used for the immunohistochemical staining. The morphology and size of thermally altered areas in both lesions were investigated and the amount of macrophages in lesion area were compared. After-effects of both surgical methods were found similar by SDS-PAGE. Thermal effect of electrosurgical unit on brain tissue was ~160% greater than that of laser. The accumulation of macrophages/microglia 7 days after the surgery in electrolytic lesion was nearly ~60% greater than that of laser lesion. No carbonization was observed in any electrolytic lesions. Finally it was found that, 980-nm diode laser (2W/2sec) can be an alternative to electrosurgical unit (1.5mA/20sec) to be used in neurosurgery.

Benzer Tezler

  1. Investigation of 980-nm diode laser parameters for soft tissue surgery

    Yumuşak doku cerrahi operasyonları için 980-nm diyot lazer parametrelerinin araştırılması

    YUSUF KORKMAZ

    Yüksek Lisans

    İngilizce

    İngilizce

    2006

    BiyomühendislikBoğaziçi Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. MURAT GÜLSOY

  2. Nır-ır laserlerin karaciğer üzerindeki etkilerinin ın vıtro ortamda araştırılması ve karşılaştırılması

    In vitro investigation and comparison of nir-ir lasers effects in liver tissue

    FİKRET YILDIZ

    Yüksek Lisans

    Türkçe

    Türkçe

    2012

    Elektrik ve Elektronik Mühendisliğiİstanbul Teknik Üniversitesi

    Elektronik ve Haberleşme Mühendisliği Ana Bilim Dalı

    DOÇ. DR. MURAT GÜLSOY

    PROF. DR. İNCİ ÇİLESİZ

  3. Gingivektomi sonrası düşük doz lazer uygulamasının yara iyileşmesine etkisinin incelenmesi

    Evaluation of the effect of low level laser therapy after gingivectomy on wound healing

    YÜKSEL KIRAN

    Doktora

    Türkçe

    Türkçe

    2016

    Diş HekimliğiGaziantep Üniversitesi

    Periodontoloji Ana Bilim Dalı

    DOÇ. DR. KAMİLE ERCIYAS

    PROF. DR. AYŞE BELGİN BAL

  4. Venöz yetmezlik tedavisinde endovenöz obliterasyon teknikleri uygulanan ve klasik stripping operasyonu yapılan hastaların uzun dönem sonuçlarının karşılaştırılması

    Comparison of endovenous obliteration techniques and stripping operations in the treatment of venous insufficiency

    NUR DİKMEN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2016

    Göğüs Kalp ve Damar CerrahisiAnkara Üniversitesi

    Kalp ve Damar Cerrahisi Ana Bilim Dalı

    PROF. DR. BÜLENT KAYA

  5. Bazı III-V ve II-VI bileşik yarı iletkenlerde elektriksel ve optik karakterizasyon

    Başlık çevirisi yok

    SEYDİ DOĞAN

    Doktora

    Türkçe

    Türkçe

    2001

    Fizik ve Fizik MühendisliğiAtatürk Üniversitesi

    Fizik Ana Bilim Dalı

    PROF. DR. SEBAHATTİN TÜZEMEN