Geri Dön

Metal desteksiz adeziv köprülerin mekanik direncinin in-vitro olarak incelenmesi

Fracture resistance of adhesive metal-free fixed partial dentures: An in-vitro study

  1. Tez No: 164037
  2. Yazar: EMRE ORHON KUYBULU
  3. Danışmanlar: PROF.DR. DENİZ GEMALMAZ
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2005
  8. Dil: Türkçe
  9. Üniversite: Marmara Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

1. ÖZET Bu çalışmanın amacı; iki farklı metal desteksiz restorasyon materyalinin (IPS Empress 2, Adoro-Vectris), tam kaplama ve inley destekli köprülerde kırılma dirençlerinin tespit edilmesidir. 50' şer alt premolar ve alt molar doğal diş 7 ve 18 mm.'lik iki farklı gövde uzunluğu oluşturmak üzere akrilik bloklara gömüldü. İki farklı metal desteksiz restorasyon tipinde her gövde uzunluğu ve preparasyon biçimi için 5 'er köprü restorasyonu hazırlandı. Ayrıca her gövde uzunluğu için kontrol grubu olarak tam kaplama metal-seramik restorasyonlar hazırlandı. Metal desteksiz restorasyonlar rezin siman ile metal-seramik restorasyonlar ise çinkofosfat siman ile yapıştırıldı. 5° C ve 55° C'de 5000 kez ısısal çevirim işlemini takiben örnekler dikey yükleme ile kırıldı. İstatistiksel analiz için Varyans Analizi ve Tukey's Multiple-Range Test' kullanıldı. Deney grupları için elde edilen ortalama kırılma değerleri (N) ve standart sapma oranlan aşağıdaki gibidir: 7 mm. gövde 18 mm. gövde Tam kaplama İnley destekli Tam kaplama İnley destekli IPS Empress 2 388.8(61.4) 480.6(106.4) 335.8(44.9) 404.0(80.4) Adoro-Vectris 1307.8(217.9) 1189.2(199.0) 1164.0(158.0) 1259.2(241.5) Metal-seramik 3457.2(277.3) * 921.0(176.6) * Materyal ve gövde uzunluğuna göre sonuçlar istatistiksel olarak anlamlı farklılık gösterirken tutucu tipinin sonuçlara anlamlı etkisinin olmadığı belirlendi (PO.05). En yüksek dayamklılık değeri her iki gövde uzunluğunda da metal-seramik köprülerde elde edildi. Adoro-Vectris fiberle güçlendirilmiş kompozit esaslı restoratif materyal yüksek esneme direncine bağlı olarak hem inley hem de tam kron tutuculu köprülerde metal- seramik sisteme yakın bir kırılma direnci gösterdi. IPS Empress 2 tam seramik sistemi ise camsı yapısı dolayısı ile daha yüksek kırılganlığa sahip olduğu için farklı tutucularda ve farklı gövde uzunluklarında en düşük kırılma direnci değerini verdi.

Özet (Çeviri)

2. SUMMARY FRACTURE RESISTANCE OF ADHESIVE METAL-FREE FIXED PARTIAL DENTURES : AN IN VITRO STUDY The aim of this study was to determine the fracture strenghts of two metal-free fixed partial denture (FPD) materials (IPS Empress 2, Adoro-Vectris) in inlay-retained and full veneer retainer designs. 50 mandibular premolar and 50 mandibular molar teeth were embedded into acrylic resin with two different span lengths (7 and 18 mm.). Five FPDs were constructed for each type of material on each span length and retainer design. Full veneer ceramo-metal FDPs on both span lengths were used as control groups. Metal-free FPDs were luted with a resin cement while ceramo-metal FDPs were cemented conventionally. FPDs were vertically loaded until fracture following the thermocycling process (5000 times) that was performed between 5 and 55° C. Statistical analyses was performed using the Variance Analyses and the Tukey's Multiple-Range Test. Mean fracture resistances (N) and standart deviations of FPDs are presented in the following table : 7 mm. span length 18 mm. span length Full veneer Inlay retained Full veneer Inlay retained IPS Empress 2 388.8(61.4) 480.6(106.4) 335.8(44.9) 404.0(80.4) Adoro-Vectris 1307.8(217.9) 1189.2(199.0) 1164.0(158.0) 1259.2(241.5) Ceramo-metal 3457.2(277.3) * 921.0(176.6) * Type of material and span length exhibited a significant influence on fracture resistance regardless of the retainer type (P<0.05). Ceramo-metal FPDs showed the highest mean fracture resistance on both span lengths. Adoro-Vectris fiber reinforced FPDs showed close results to the ceramo-metal FPDs on both types of retainers, due to their high modulus of elasticity. IPS Empress 2 glass-ceramic FPDs exhibited the lowest fracture resistance on both span lengths and each type of retainer.

Benzer Tezler

  1. Bazı esterlerin kinetik incelenmesi ve termodinamik parametrelerin belirlenmesi

    Kinetic study and detesmination of thermodnamic parameters of some esters

    İBRAHİM TAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Uludağ Üniversitesi

    Kimya Ana Bilim Dalı

    Yükleniyor...

  2. Adolesan intihar girişimlerinin psiko-sosyal nedenleriyle ilgili araştırma

    Başlık çevirisi yok

    NAZMİYE YÜKSEL

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    İstanbul Üniversitesi

    Aile Sağlığı Ana Bilim Dalı

    Yükleniyor...

  3. İnce taneli sementasyon çeliklerinde sıcak şekil verme ve ısıl işleminin ostenit tane büyüklüğüne etkisi

    Başlık çevirisi yok

    MERAL ŞANLI

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Uludağ Üniversitesi

    Fizik Ana Bilim Dalı

    Yükleniyor...

  4. Plazma arkı eldesi ve yüzey bölgesi modifikasyonunda kullanılabilirliği

    Başlık çevirisi yok

    ÖZKAN ÖZİPEKLİLER

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Uludağ Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  5. 1,3-difenil-4,5-bis(hidroksiimino)-imidazolidin ve Ni(II), Cu(II), Pd(II), UO2(VI) komplekslerinin sentezi

    Başlık çevirisi yok

    VEFA AHSEN

    Doktora

    Türkçe

    Türkçe

    1984

    Uludağ Üniversitesi

    Kimya Mühendisliği Ana Bilim Dalı

    Yükleniyor...