Geri Dön

Minimization of inhomogeneities in magnetic resonance mammography

Manyetik rezonans mamografisinde düzensizliklerin en aza indirgenmesi

  1. Tez No: 181190
  2. Yazar: ORKUN SERDAR DOĞRULUK
  3. Danışmanlar: DOÇ. DR. HALİL ÖZCAN GÜLÇÜR
  4. Tez Türü: Yüksek Lisans
  5. Konular: Biyomühendislik, Bioengineering
  6. Anahtar Kelimeler: Manyetik rezonans mamografisi, alan düzensizlikleri, homomorfiksüzgeçleme, entropi, Magnetic resonance mammography, field inhomogeneity, homomorphic filtering, entropy minimization
  7. Yıl: 2006
  8. Dil: İngilizce
  9. Üniversite: Boğaziçi Üniversitesi
  10. Enstitü: Biyo-Medikal Mühendislik Enstitüsü
  11. Ana Bilim Dalı: Biyomedikal Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 81

Özet

Manyetik rezonans mamografisi (MRM), X-ışınlı mamografi ve ultrases ilebelirlenemeyen çok küçük lezyonlar hakkında ayrıntılı bilgi vermesi nedeniyle gelenekselmamografiye yardımcı bir araç olarak 1991 yılından beri kullanılmaktadır. Yüksek kanseroluşturma riskine sahip kadınlar, meme dokusunun tamamının alınmadığı lumpektomiameliyatı geçirenler veya yüksek miktarda DCIS (ductal carcinoma in situ) içeren yoğunmeme dokusuna sahip kadınlar MRM için uygun hastalardır.Meme görüntülerinin çözünürlüğü gerek iyi huylu ve kötü huylu lezyonların ayırtedilmesi gerekse uygun tedavi yöntemlerinin belirlenmesi açısından oldukça önemlidir.Duruk ve ikincil manyetik alanların homojen olmaması ve alıcı sarımdaki düzensizliklerçözünürlük üzerinde olumsuz sonuçlara neden olur. Bu etkiyi azaltmak için çeşitli yöntemlerönerilmiştir. Bu tez çalışmasında belirtilen düzensizliklerden kaynaklanan etkileri azaltmakiçin yeni bir gelişmiş homomorfik süzme yöntemi önerilmiştir. Diğer homomorfik süzmeyöntemlerinden farklı olarak, süzmeden kaynaklanan sorunları engellemek amacıyla bir dokumaskesi uygulanmış ve sapma alanı alçak geçiren süzgeç yardımıyla belirlenmiştir. Enuygungörüntü görüntü elde edilen sapma alanının, çekim sonucu elde edilen görüntüdençıkarılmasıyla bulunur. Süzgeçleme için bir frekans aralığı belirlenmiş ve farklı kesmesıklıkları için belirli sayıda sapma alanı ve enuygun görüntü elde edilmiştir. Entropi azaltmayöntemi, alçak geçiren süzgeçin enuygun kesme sıklıklarını belirlemek amacıylakullanılmıştır. Bu yöntem hızlı, kullanıcıdan ve parametrelerden bağımsız bir algoritmaoluşturmaktadır. Yöntem farklı hastalardan alınan görüntüler üzerinde denenmiştir. Ayrıcayeni bir nicel başarım çözümleme yöntemi önerilmiştir.

Özet (Çeviri)

Magnetic Resonance Mammography (MRM), accepted by for use as a supplementaltool to mammography in 1991, provides detailed information about very small lesions that X-ray mammography and ultrasound often cannot detect. Women who are at increased risk fordeveloping cancer, or those who have completed breast conserving ?lumpectomy?, youngwomen with dense breasts or those with a great amount of DCIS (ductal carcinoma in situ) aregood candidates for MRM.Resolution of the breast imaging is important for improving differentiation betweenbenign and malignant lesions and for refining treatment strategy. Inhomogeneity of thestatic magnetic field or secondary magnetic field and nonuniformity of the receiver coil haveadverse effects on resolution. A number of methods have been proposed to minimize theseeffects. In this thesis work we present a novel improved homomorphic filtering method tominimize artifacts caused by these inhomogeneities. Unlike other homomorphic filteringmethods, we apply a tissue mask to eliminate filter artifacts, and then apply low-pass filteringto estimate the bias field. Restored image is obtained by the difference of the original imageand the estimated bias field. A frequency range is defined and a number of bias fields andrestored images are estimated for each image. Entropy minimization is used to define anoptimum cutoff frequency of the low-pass filter. This results in a fast, user independent,nonparametric algorithm. The method is demonstrated on various breast images fromdifferent patients. A performance evaluation method is also defined for quantitativemeasurement.

Benzer Tezler

  1. Mınımızatıon of torque rıpples of ınterıor permanent magnet synchronous motors

    Gömülü kalici miknatisli senkron motorlarin moment dalgalanmalarinin minimizasyonu

    EMRULLAH AYDIN

    Yüksek Lisans

    Türkçe

    Türkçe

    2014

    Elektrik ve Elektronik MühendisliğiGazi Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    DOÇ. DR. MEHMET TİMUR AYDEMİR

  2. Minimization of torque ripples and speed control of switched reluctance motor through fuzzy logic based direct torque control method

    Bulanık mantık tabanlı doğrudan moment denetimli anahtarlamalı relüktans motorun moment dalgalarının azaltılması ve hız kontrolü

    HAFEEZUL HAQ

    Yüksek Lisans

    İngilizce

    İngilizce

    2017

    Elektrik ve Elektronik MühendisliğiKaradeniz Teknik Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    DOÇ. DR. HALİL İBRAHİM OKUMUŞ

  3. Deney tasarımı yöntemleri ile kalite hatalarının minimizasyonu

    Minimization of quality faults with experimental design methods

    YUSUF ZİYA ÇİÇEK

    Yüksek Lisans

    Türkçe

    Türkçe

    2018

    Endüstri ve Endüstri MühendisliğiErciyes Üniversitesi

    Endüstri Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. FEYZA GÜRBÜZ

  4. Elektrik güç sistemlerinde transformatörlerin yaşlanması koşulları altında verimlilik artışı amaçlı işletim koşullarının iyileştirilmesinin araştırılması

    Research on improving the operational conditions of the transformers in the electric power system under ageing studies

    BANU ÖZTÜRK UÇAR

    Doktora

    Türkçe

    Türkçe

    2020

    Elektrik ve Elektronik Mühendisliğiİstanbul Teknik Üniversitesi

    Elektrik Mühendisliği Ana Bilim Dalı

    PROF. DR. MUSTAFA BAĞRIYANIK