Çevresel tel tespitinin kortikal kemik kan akımına akut etkisi
The acut effect to cortical bone blood flow of the circumferential wire fixation
- Tez No: 196154
- Danışmanlar: PROF.DR. OKAY BULUT
- Tez Türü: Tıpta Uzmanlık
- Konular: Ortopedi ve Travmatoloji, Orthopedics and Traumatology
- Anahtar Kelimeler: Serklaj teli, Lazer Doppler Flowmetre (LDF), kortikal kan akımı, medüller dolaşım, sokak köpeği, Cerclage wire, Laser Doppler flowmetry (LDF), Cortical bone perfusion, medüller perfusion, stray dog
- Yıl: 2006
- Dil: Türkçe
- Üniversite: Cumhuriyet Üniversitesi
- Enstitü: Tıp Fakültesi
- Ana Bilim Dalı: Ortopedi ve Travmatoloji Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Kemik kanlanması üzerinde daha çok çalışma yapılabilecek, ortaya çıkarılmamış birçok soruya sahip, tezat bulgular içeren geniş bir konudur. Kemiğin kanlanması ve içten tespit materyallerinin kanlanmaya etkileri ile ilgili birçok çalışma yapılmış ve yeni materyaller piyasaya sunulmuştur. Fakat çevresel tel tespitinin kortikal kemiğin kanlanmasına akut etkisi Lazer Doppler Flowmetre (LDF) ile daha önce hiç ölçülüp değerlendirilmemiştir. Biz yaptığımız bu çalışmada çevresel tel tespitinin femoral kortikal kan akımına akut etkisini deneysel köpek modelinde araştırdık. Çalışmamızda 1-3 yaşında iskelet olarak matur 6 adet sokak köpeği kullandık. Bu köpeklerin sağ femur diyafizine 2x2 cm periostal pencere açıp LDF (Periflux 4001 Master, Perimed) ile ilk ölçümü aldıktan sonra ölçülen noktanın 1 cm proksimaline çevresel tel uygulayıp 2. ölçümü aldık, bu noktanın 1 cm distaline 2. bir çevresel tel yerleştirilip aynı noktadan ölçümü tekrarladık. Köpekleri çalışma sonunda doğal ortamlarına geri bıraktık. Sonuçlar Friedman ve Wilcoxon testi kullanarak istatistiksel olarak değerlendirdi. Değerlendirme sonucunda ortalama bazal femoral kortikal kan akımında (26.87±8.24 pü), ilk çevresel tel tespitinden sonra (9.98±3.40 pü) ve 2. çevresel tel tespitinden sonra (3.69±1.44 pü) belirgin azalma tespit edildi. Bunun da istatistiksel olarak anlamlı olduğunu gördük (p<0.05). Sonuçta; kemiğin medüller, periosteal veya her ikisinin dolaşımın bozulduğu herhangi bir durumda, çevresel tel tespitinin gecikmiş kaynama, kaynamama veya enfeksiyon riskini arttıracağı düşüncesindeyiz. Bu konuda yapılacak yeni çalışmaların konunun daha da aydınlatılmasını sağlayacağını ve belki de bu sayede yeni materyallerin piyasaya sürülebileceğini söyleyebiliriz.
Özet (Çeviri)
Bone blood flow is large subject which is still open for further analysis. There are a lot of unanswered questions and contradictive findings about this subject. Although there are a lot of research and development effort accomplished in the area of bone blood flow and the effects of internal fixation materials on it, the acute effect of the circumferential wire fixation on the cortical bone has not been researched yet with the help of Laser Doppler flowmetry (LDF). In this study, the acute effect of the circumferential wire fixation on femoral cortical blood flow is researched with an experimental model using dogs as cavies. During this research, 6 different 1 to 3 years-old stray dogs with mature skeleton structure have been examined. As a first step, a 2x2 cm periosteal window has been opened on the right femur diafiz of the dogs and first measuring value has been obtained by LDF using a custommade probe (Periflux 4001 Master, Perimed). The second measuring value has been obtained by applying a circumferential wire to 1 cm proximal of the first point. As a next step, second circumferential wire is implanted to 1 cm distal of this point and the same measurement has been repeated. After examination, the dogs have been released to their natural environment. The results have been evaluated statistically by using Friedman and Wilcoxon test. As a result of this evaluation, it has been observed that the average basal femoral cortical blood flow (26.87±8.24 pü) has decreased significantly after first (9.98±3.40 pü) and second (3.69±1.44 pü) circumferential wire fixation application. Since pvalue of Gaussian distribution is under the critical value (p<0.05), the conclusion, that the circumferential wire fixation application causes significant deduction of average basal femoral cortical blood flow, is accepted as a valid statement. In conclusion; in the situation of any perfusion disturbance of bone? s medüller or periosteal, or that of both we believe that the circumferential wire fixation will increase the risk of delayed union, nonunion and infection. It can be stated that further analysis in this context would enable that this subject is enlightened more detailed and thus new materials are emerged in the related market.
Benzer Tezler
- Landsat uydusu aracılığı ile elde edilen görüntülerin sınıflandırılmaları ve bunlara ilişkin bilgisayar programlarının hazırlanması
Başlık çevirisi yok
G. FERZAN KÜÇÜKA
Yüksek Lisans
Türkçe
1985
Ege ÜniversitesiBilgisayar Bilimleri ve Mühendisliği Ana Bilim Dalı
Yükleniyor...
- Türkiye trafik düzeninde kazaların azaltılması açısından yeni trafik kanunu uygulaması ile ilgili sorunlar ve çözüm yolları
Başlık çevirisi yok
ERDAL UÇAR
Yüksek Lisans
Türkçe
1986
Gazi ÜniversitesiKazaların Çevresel ve Teknik Araştırması Ana Bilim Dalı (disiplinlerarası)
Yükleniyor...
- Ankara-Kızılcahamam karayolunda meydana gelen trafik kazalarında insan faktörü
Başlık çevirisi yok
CELAL AKBULUT
Yüksek Lisans
Türkçe
1987
Gazi ÜniversitesiKazaların Çevresel ve Teknik Araştırması Ana Bilim Dalı (disiplinlerarası)
Yükleniyor...
- Mikrobiyoloji laboratuvarlarında kaza nedeni oluşan enfeksiyonlar
Başlık çevirisi yok
ŞENAY TÜRE
Yüksek Lisans
Türkçe
1986
Gazi ÜniversitesiKazaların Çevresel ve Teknik Araştırması Ana Bilim Dalı (disiplinlerarası)
Yükleniyor...
- Çocuklarda kimyasal maddeler ve diğer nedenlerle zehirlenme sıklığı
Başlık çevirisi yok
BİRCAN ÖZDEMİR
Yüksek Lisans
Türkçe
1986
Gazi ÜniversitesiKazaların Çevresel ve Teknik Araştırması Ana Bilim Dalı (disiplinlerarası)
Yükleniyor...