Geri Dön

Göz içi basınç artışı karın içi basıncını yansıtır mı?

Is the increase of intraocular pressure shows the intraabdominal pressure?

  1. Tez No: 248828
  2. Yazar: İLHAN ECE
  3. Danışmanlar: DOÇ. DR. CELALETTİN VATANSEV
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Genel Cerrahi, General Surgery
  6. Anahtar Kelimeler: Abdominal duvar, Göz, Göz hastalıkları, İntraabdominal hipertansiyon, İntraoküler basınç, Abdominal wall, Eye, Eye diseases, Intraabdominal hypertension, Intraocular pressure
  7. Yıl: 2010
  8. Dil: Türkçe
  9. Üniversite: Selçuk Üniversitesi
  10. Enstitü: Meram Tıp Fakültesi
  11. Ana Bilim Dalı: Genel Cerrahi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Karın içi basınç 12 mmHg'yı aştığında intraabdominal hipertansiyondan bahsedilir ve karın içi organlar etkilenmeye başlar. Abdominal kompratman sendromun da ise 20 mmHg üzerinde karın içi basınç ve organ hasarı mevcuttur. İntraabdominal basınç karın içine yerleştirilen port vasıtasıyla doğrudan ölçülebildiği gibi transvezikal, transgastrik yöntemle dolaylı olarak ölçülebilmektedir. Çalışmamızda; diğer dolaylı ölçüm metodlarına alternatif olarak daha az invazif ve kolay bir yöntem olan göz içi basıncını ölçerek karın içi basınç hakkında fikir sahibi olmayı amaçladık.Yöntem: Çalışmaya 18-55 yaş arası daha önce okuler patolojisi olmayan, vücut kitle indeksleri birbirine yakın ve ASA skoru I-II olan 40 hasta dahil edildi. Etik kurul onayı alındıktan sonra hastalara yapılacak işlemler hakkında bilgi verilip yazılı onamları alındı. Hastalar 10'ar kişilik 4 gruba ayrıldı. Kontrol grubu abdominal operasyon uygulanmayan hastalardan seçildi. Diğer 3 grup laparoskopik operasyon için CO2 ensüflasyonu yapılacak hastalardan oluşturuldu. 1. grup (Kontrol grubu) hastalara abdominal operasyon uygulanmadı. 2. gruba 9 mmHg basınçla laparoskopik ameliyat yapıldı. 3. ve 4. gruba sırasıyla 12 ve 15 mmHg basınçla laparoskopik ameliyat ugulandı.Premedikasyon sonrası ilk okuler basınç ölçümü anestezi indüksiyonu öncesinde Perkins Hand Held Applanation Tonometre cihazı ile operasyon masasında yapıldı. Anesteziye bağlı değişiklikleri ortadan kaldırmak için tüm hastalarda standart bir anestezi protokolü izlendi. Entübasyonun göz içi basınç artışına neden olan etkisini değerlendirebilmek için ikinci intraokuler basınç ölçümü entübasyondan sonra yapıldı. Son ölçüm uyanmanın göz içi basıncını artırma ihtimalini ortadan kaldırmak için hasta uyanmadan yapıldı. İstatistiksel analizde Tekrarlı Ölçümlerde Varyans Analizi ve çoklu karşılaştırmada Posthoc Tukey testi kullanıldı. Ölçümler arası farkı saptamak için bağımlı gruplarda Bon-Ferroni düzeltmeli T testi uygulandı. P< 0.05 olan değerler anlamlılık düzeyi olarak kabul edildi.Bulgular: Tüm gruplarda 1.ve 2. ölçüm arasında entübasyondan kaynaklanan anlamlı fark olduğu saptandı. Bazal değer olan 1. ölçüm ve son değer olan 3. ölçüm arasında sadece 2. ve 4. grupta fark bulundu. Gruplar karşılaştırıldığında ise 1. ve 2. grubun benzer 3. 4. grubun benzer sonuçlara sahip olduğu görüldü.Sonuç: Karın içi basıncı 12 mmHg'nin üzerinde olan gruplarda göz içi basıncı da artmıştır. Artmış karın içi basıncının takibinde göz içi basınç ölçümü güvenilir alternatif bir metod olarak kullanılabilir.

Özet (Çeviri)

Aim: When intraabdominal pressure pass over to 12 mmHg ,we can discussed intraabdominal hypertension and it effects all intraabdominal organs. At abdominal compartment syndrome intraabdominal pressure more than 20 mmHg and there is an organ injuries. Intraabdominal pressure can be measured by intraabdominally positined port or it can also measured by transvesical and transgastric methods. In our study; we aimed to hold a view intraabdominal pressure by intraocular pressure measurement which is less invasive and simple than other alternative measurement methods.Methods: In this study,18-55 years old 40 patients included with no previous ocular pathology , ASA score I-II and their body mass index close to each to other. After ethics committees approval we give information about procedure and we get their agreement. We have 4 groups each have 10 patients. First 10 patients intraabdominal operation didn?t applied were control group, other 3 groups patients insufflated with CO2 respectively 9, 12 and 15 mmHg pressure for laparoscopic cholecystectomy .After premedication, first intraocular pressure measured by Perkins Hand Held Applanation Tonometer before induction of anesthesia at operation room. All patients have same standart anesthesia protocol in order to eliminate anesthesia depended alterations. In order to evaluate entubation related intraocular pressure increasement, second intraocular pressure measurement applied after entubation. Because of intraocular pressure increasement possibility of awaking ,last measurement applied before patients awake.We use Posthoc Tukey Test at statistical analysis for recurrent measurement, variance analysis and multiple comparision. In order to determine measurement difference dependent groups Bon-Ferroni correction T-test applied.Findings: All groups 1. and 2. meaningful measurement difference related with entubation. Between basic value (1.measurement )and last value (3.measurement) only 2. and 4. groups there were difference. When we compare all groups 1. and 2. groups ,3.and 4 groups have similar results.Results: In groups which intraabdominal pressure more than 12 mmHg, intraocular pressure increased. Intraocular pressure measurement is an alternative and reliable method in intraabdominal pressure pursuit.

Benzer Tezler

  1. Diesel motorları yakıt püskürtme sistemlerinin dinamik simülasyonu

    Başlık çevirisi yok

    İRFAN KARAGÖZ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Uludağ Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  2. Baba yoksunluğunun benlik kavramına etkisi ve babasız öğrencilerin problemlerinin hangi alanlarda yoğunlaştığının saptanması

    Başlık çevirisi yok

    OYA GÜNGÖRMÜŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    İstanbul Üniversitesi

    Gelişim Psikolojisi Ana Bilim Dalı

    Yükleniyor...

  3. Konfeksiyon işletmelerinde performans ölçümleri ve işgücü planlanmasına katkıları

    Başlık çevirisi yok

    SEVİN BRAV

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Tekstil Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  4. NaI (TI) dedektörleri için toplam verim ve tüm enerji pik duyarlığının Monte Carlo metodu ile elde edilmesi

    Başlık çevirisi yok

    N. REMZİYE ERGÜL

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Uludağ Üniversitesi

    Fizik Ana Bilim Dalı

    Yükleniyor...

  5. Bazı buğday türlerinde poliploidi düzeyine bağımlı IAA ve ABA miktarlarının kantitatif belirlenmesi üzerine bir araştırma

    Başlık çevirisi yok

    SEVGİ HEPAKSOY

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Botanik Ana Bilim Dalı

    Yükleniyor...

  6. Acenaphthene uygulaması ile tütün dihapladlerinin elde edilmesi üzerinde bir araştırma

    Başlık çevirisi yok

    SERVET KEFİ

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Tarla Bitkileri Ana Bilim Dalı

    Yükleniyor...