Geri Dön

Oncor lineer hızlandırıcısında elektron ışın demetlerinde alan dışındaki dozların araştırılması

Research about the peripheral dose outside the applicators in electron beams of oncor linear accelerator

  1. Tez No: 281709
  2. Yazar: BAŞAK İKTÜEREN
  3. Danışmanlar: PROF. DR. HATİCE BİLGE
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Onkoloji, Physics and Physics Engineering, Oncology
  6. Anahtar Kelimeler: Elektron, Elektron demeti, Elektron dozimetresi, Parçacık hızlandırıcılar, Radyometri, İyon odası, Electron, Electron beam, Electron dosimeter, Particle accelerators, Radiometry, Ionization chamber
  7. Yıl: 2010
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Temel Onkoloji Ana Bilim Dalı
  12. Bilim Dalı: Tıbbi Radyofizik Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmada, Oncor lineer hızlandırıcısının elektron demetlerinde alan dışındaki dozların belirlenmesi ve bu dozların tedavi planlama bilgisayarından elde edilen doz eğerleri ile karşılaştırılması amaçlandı.Su eşdeğeri katı fantomda paralel plan iyon odası kullanılarak 6, 9 ve 15 MeV elektron enerjilerinde 5x5 cm2, 10x10 cm2, 15x15 cm2, 20x20 cm2, 25x25 cm2 alanlarında, 00, 100, 200 gantry açılarında, yüzey, 0.2 cm, 0.5 cm, 1 cm ve her enerjinin dmax derinliklerinde doz profilleri ölçüldü. Ölçülen değerler alan merkezine normalize edilerek alan dışındaki dozlar belirlendi.6 ve 9 MeV enerjili elektron ışın demetleri için gantry 00'de 10x10 cm2'lik alanda alan kenarından 6 cm uzaklıkta alan merkezinde %100 olmak üzere yüzeyde %1.4'lük, 15 MeV enerjili elektron ışın demetlerinde ise %2.3'lük bir doz piki olduğu gözlenmiştir. Bu piklerin derinlik arttıkça azalarak minimuma indiği ve alan boyutu büyüdükçe de %2.5-4'e ulaştığı görülmüştür. Gantry 100 ve 200'de ise 6 ve 9 MeV enerjili elektronların çok küçük pikler oluşturduğu, 0.2 ve 1 cm derinliklerinde alan kenarından 3 cm uzaklıkta maksimum doza ulaşamadıkları görülmüştür. 15 MeV enerjili elektron ışınları ise Gantry 100 ve 200 açılarında 0.2 ve 1 cm deinlikte pik görülmemiştir. Alan dışında ölçülerek bulunan dozlar, Pencil Beam algoritması kullanarak hesaplama yapan tedavi planlama bilgisayarından elde edilen dozlarla karşılaştırıldığında alanın 3 cm dışına kadar olan bölgede doz hesaplaması yapabildiği görüldü.Çalışmanın sonunda, alan dışı dozlarının belirlenmesinde planlama sisteminin yeterli olmadığı, bu dozların ancak ölçülerek bulunabileceği görüldü.

Özet (Çeviri)

In this study, the peripheral dose outside the applicator was measured using electron beams produced by Oncor linear accelerator and compared with the datas of treatment planning system (TPS).The dose profiles has been measured by using water-equivalent slab phantom and parallel plate ionization chamber; in 6, 9 and 15 MeV energies at 5x5 cm2, 10x10 cm2, 15x15 cm2, 20x20 cm2, 25x25 cm2 applicators and 00, 100, 200 gantry angels; surface, 0.2 cm, 0.5 cm, 1 cm and dmax depth of every electron enegies. The peripheral dose has been determined with this profiles by normilize at the field central beam axis.It has been notice that using the 10x10 cm2 applicator, there is %1.4 dose peak on surface 6 cm far from the field edge which the field central beam axis (CAX) has %100, at gantry 00 for 6 and 9 MeV electron beams and for 15 MeV electron beams there is also %2.3 dose peak. It has been found out that peak dose gets closer to minimum depending on the increase of the depth and reaches %2.5-4 depending on growth of field demension. In gantry 100 and 200; 6 and 9 MeV electron beams created small peaks at and it could reach to maximum dose at 0.2 and 1 cm depth. 15 MeV electron beams did not peak at 0.2 and 1 cm depth in gantry 100 and 200. The peripheral dose outside the applicators which is measured has been compared with the datas of treatment planning system?s computer by using Pencil Beam algorthim, it has been presented that dose calculation can be made until 3 cm outside of the field.The end of the study, the treatment planning system is not enough to measure the peripheral dose outside the applicators, and this dose can be found only by measuring.

Benzer Tezler

  1. Ön işlemenin ve askorbik asitin dondurularak depolanan yılan balıklarının (Anguilla anguilla) kalitesine etkileri

    Başlık çevirisi yok

    H.VOLKAN GÖKSEL

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Su Ürünleri Ana Bilim Dalı

    Yükleniyor...

  2. Transformatör sargılarında oluşan hızlı değişimli geçici olayların incelenmesi ve enerji iletim sistemlerinin modellenmesinde yeni bir yaklaşım

    Investigation of high speed transients on transformer windings and a new approach in modelling of energy transmission systems

    A.OĞUZ SOYSAL

    Doktora

    Türkçe

    Türkçe

    1985

    İstanbul Teknik Üniversitesi

    Yükleniyor...

  3. İnegöl'de çeşitli ölçeklerdeki mobilya işletmelerinin sosyo-ekonomik analizi

    Başlık çevirisi yok

    MUSTAFA ÖNCER

    Yüksek Lisans

    Türkçe

    Türkçe

    1984

    İstanbul Üniversitesi

    Orman Ekonomisi Ana Bilim Dalı

    Yükleniyor...

  4. Augustinus estetik'ine genel bir bakış

    Başlık çevirisi yok

    AYŞE SERPİL BAHADIRLI

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    İstanbul Üniversitesi

    Yükleniyor...

  5. Patateste çeşitli tarımsal ve fizyolojik özelliklerin kalıtımı ve bunlar arasındaki ilişkiler

    Başlık çevirisi yok

    MÜMTAZ ERASLAN

    Doktora

    Türkçe

    Türkçe

    1988

    Ege Üniversitesi

    Tarla Bitkileri Ana Bilim Dalı

    Yükleniyor...