Tavandan soğutulan bir hacimde sıcaklık ve nem dağılımının deneysel ve sayısal analizi

Experimental and numerical investigation of temperature and humidity distribution in an enclosure with chilled ceiling

  1. Tez No: 295383
  2. Yazar: DENİZ YILMAZ
  3. Danışmanlar: PROF. DR. SEYHAN UYGUR ONBAŞIOĞLU
  4. Tez Türü: Doktora
  5. Konular: Makine Mühendisliği, Mechanical Engineering
  6. Anahtar Kelimeler: Doğal taşınım, Natural convection
  7. Yıl: 2011
  8. Dil: Türkçe
  9. Üniversite: İstanbul Teknik Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmada, tavandan soğutulan 2.5x2.5x2.5(m) boyutlarında bir test odası kurularak, tavan boşluk oranı ve akustik şiltenin kapalı hacimdeki sıcaklık ve nem dağılımına etkileri irdelenmiştir. Rayleigh sayısının 4x109 olduğu deney koşullarında, yüksek doğal taşınım etkisindeki akış modellenmiş ve geliştirilen sayısal yöntem deneylerle doğrulanmıştır. Deneysel veriler, türbülanslı doğal taşınımı modelleyen farklı yaklaşımlar arasında karşılaştırma yapılmasını sağlamıştır. Uygun türbülans modelinin seçimi ile geometrik parametrelerin etkisinin sayısal olarak belirlenmesi olanaklı olmuştur. Momentum ve enerji denklemlerinin, hava içerisindeki su buharının transportu denklemi ile birlikte çözüldüğü çalışmada, duvar yüzeylerindeki yoğuşma da incelenmiştir. Deneysel ve sayısal olarak elde edilen korelasyonlar, literatürde verilen korelasyonlarla uyum sağlamıştır.Çalışmada, tavan panellerindeki boşluk oranı artışının, oda içerisindeki hava akışının boru yüzeylerine daha fazla temas etmesine ve taşınımla olan ısı geçişinin artmasına neden olduğu gözlemlenmiştir.Tavan panellerinin yüzeyine serilen akustik şiltenin ısı geçişini azalttığı; öte yandan kütle geçişini büyük ölçüde engellediği için bağıl nemi arttırdığı gözlemlenmiştir.Standart k-? türbülans modelinin, türbülansın dissipasyonu yerine, spesifik dissipasyon denklemini çözmesi nedeniyle, geçici rejimde; RNG k-? modelinin ise yüksek hız gradyanlarında çözüm yapabilmesi nedeniyle, çekirdek bölge olarak adlandırılan kısımda deneysel verilere daha uygun sonuçlar verdiği gözlemlenmiş; nem dağılımını belirlemede türbülans modellerinin katkısı da ayrıca incelenmiştir.Çalışmada ayrıca oda içerisine yerleştirilen soğuk nem kaynağı ile nem üretimi yapılmış, tavan yüzeyinde ve oda içerisindeki özgül nem ve sıcaklık değişimleri incelenmiş ve bu değişimler paket programa yerleştirilen bir kod ile sayısal olarak da modellenmiştir.

Özet (Çeviri)

This study is an experimental and numerical investigation on application of chilled ceiling panels with different porosity rate in an enclosure, having diameters of 2.5x2.5x2.5(m). The effect of porosity rate and the existence of acoustic nonwoven on temperature and humidity distribution have been investigated.Experimental investigations in the enclosure are presented for the case with Ra=4x109 and a numerical model has been used to simulate the experimental set up. Experimental results have been used to validate the numerical model. Experimental data have led to comparisons between the different turbulent modeling approaches. By selecting appropriate turbulence model, the effect of geometric parameters had become possible to be determined numerically. Momentum and energy equations have been solved with the transport equation of water vapor in the air and the numerical model was enhanced to represent the vapor condensation on the wall surfaces. Experimental and numerical correlations obtained from the study are found to be consistent with the correlations in the literature.It was observed that high porosity rate in the ceiling panels, can cause the air in the room to contact with the pipe surface much more which as a consequence lead to an increase in convective heat transfer.The acoustic nonwoven which was covered the ceiling panel?s surfaces; reduce heat transfer and because of highly preventing mass transfer an increase was observed for the relative humidity ratio.Since, Standard k-? turbulence model solves specific dissipation equation rather than turbulent dissipation, the solution for unsteady flow is more consistent with the experimental results. Besides this, RNG k-? turbulence model predicts the flow in the cell region better, due to the additional term in its turbulent dissipation equation.In this study, humidity is also generated by a cold humidity source placed in the test room. The changes in the specific humidity and temperature have been examined on the surface of the ceiling and in the test room. Additionally, these changes have been computed by a program (user defined function) appended to the software package.

Benzer Tezler

  1. Türkiye linyit ve taşkömürlerinden metalurjik amaçla karma kok üretimi

    Başlık çevirisi yok

    HASAN FERİT BERK

    Doktora

    Türkçe

    Türkçe

    1984

    İstanbul Teknik Üniversitesi

    Yükleniyor...

  2. Eşikler üzerindeki akım özellikleri ve katı tane hareketi

    Flow characteristics and sediment transport over the dunes

    ALİ ANIL

    Doktora

    Türkçe

    Türkçe

    1985

    İstanbul Teknik Üniversitesi

    Yükleniyor...

  3. Tavşanlarda marek hastalığı virusu (MHV) antikorunun eldesi ve ELISA yöntemi için katı faza immobilizasyonu

    Isolation of the antibody against Marek disease virus (MDV) from rabbits and its immobilization to solid phase for the ELİSA technique

    JAFAR GAREAYAGHİ

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Marmara Üniversitesi

    Biyokimya Ana Bilim Dalı

    Yükleniyor...

  4. 15-16-17.Yüzyıl Osmanlı mimarisinde kalem işleri

    Başlık çevirisi yok

    CANDAN NEMLİOĞLU

    Doktora

    Türkçe

    Türkçe

    1989

    İstanbul Üniversitesi

    Sanat Tarihi Ana Bilim Dalı

    Yükleniyor...