Gebelerden alınan amniyon sıvılarının karyotip analizinde normal, down sendromu ve nöral tüp defekti olduğu tespit edilen olguların amniyon sıvılarında oksidatif stres (MDA) parametrelerinin, antioksidan (SOD, CAT, GSH-Px ) ve eser element (Se, Zn, Cu ) düzeylerinin araştırılması
Result of karyotype analysis of amniotic fluids are identified as having down's syndrome, neural tube defect and normal cases, oxidative stress (MDA) parameters, antioxidant (SOD, CAT, GSH-Px) and trace element (Se, Zn, Cu) levels
- Tez No: 314455
- Danışmanlar: PROF. DR. METİN KILINÇ
- Tez Türü: Yüksek Lisans
- Konular: Biyokimya, Biochemistry
- Anahtar Kelimeler: Amniyon sıvısı, trizomi 21, nöral tüp defekti, çinko, bakır, selenyum, SOD, GSH-Px, CAT, MDA
- Yıl: 2012
- Dil: Türkçe
- Üniversite: Kahramanmaraş Sütçü İmam Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Tıbbi Biyokimya Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 72
Özet
Normal, down sendromu ve nöral tüp defekti olduğu tespit edilen gebelerden alınan amniyon sıvıları arasında eser element, oksidadatif stres ve antioksidan parametreleri arasındaki farklılıklar belirlenmeye çalışılmıştır.Bu çalışmada normal olduğu tespit edilen 235 gebeden alınan amnniyon sıvıları ile 9 down sendromlu ve 10 nöral tüp defektli gebeden alınan amniyon sıvıları arasındaki antioksidan enzim ve eser element düzeyleri karşılaştırıldı. Dokularda antioksidan enzim düzeyleri spektrometrik yöntemle, eser element düzeyleri atomik absorpsiyon spektrometresiyle ( AAS) oksidatif stres ise HPLC ile çalışıldı.Amniyon sıvılarındaki ortalama çinko, bakır ve selenyum düzeyleri kontrol grubunda sırasıyla; 6,4 µg/dl, 7,2 µg/dl ve 13,4 µg/l bulunmuş iken down sendromlu grupta sırasıyla; 5,9 µg/dl, 4,8 µg/dl ve 10,3 µg/L, nöra tüp defektli grupta ise sırasıyla 6,1 µg/dl, 5,8 µg/dl ve 11,2 µg/L olarak bulunmuştur. MDA, CAT, GSH- Px ve SOD düzeyleri kontrol grubunda sırasıyla; 0,84 nmol/ ml, 36 Ü/ml, 1,4 Ü/ml ve 1,4 Ü/ml, down sendromlu grupta; 0,9 nmol/ml, 32 Ü / ml, 2,7 Ü / ml ve 1,4 Ü /ml, nöral tüp defektli grupta ise sırasıyla; 0,8 nmol/ ml, 28 Ü / ml, 1,1 Ü/ml ve 1,6 Ü/ml olarak tespit edilmiştir. Gruplar arasında MDA, SOD ve CAT arasında istatistiksel farklılık gözlenmemiştir (p > 0,05) fakat GSH-Px de gruplar arası ilişkinin p < 0,05 istatistiksel olarak anlamlı olduğu gözlendi. Hasta ve normal gruplar arasında çinko, bakır ve selenyum arasında istatistiksel olarak herhangi bir fark tespit edilememiştir (p > 0,05).Sonuç olarak amniyon sıvılarında çinko, bakır, selenyum düzeyleri ile ve MDA, SOD ve CAT düzeyleri arasında farklılık gözlenmemesi hasta gruplarında sayının az olmasıyla ilişkilendirilebilir.
Özet (Çeviri)
Amniotic fluids taken pregnant women which identified as normal, Down syndrome and neural tube defect were studied indicating differences between trace elements, oksidadatif stress and antioxidant parameters.In this study, amniotic fluids taken pregnant women that are 235 normal, 9 having Down syndrome and 10 having neural tube defect were compared evaluating oxidative stress, antioxidant parameters and trace elements. Antioxidant enzymes, MDA and trace element levels in tissues were analysed using spectrophotometer and atomic spectrometry instrument respectively.While in amniotic fluids collected from the control group mean zinc, copper and selenium levels were 8,30 µg/dl, 8,25 µg/dl and 18,9 µg/l respectively, they were found as 6,85 µg/dl, 5,81 µg/dl and 11,24 µg/l respectively in the down syndrome group; 5,87 µg/dl, 4,77 µg/dl and 13,14 µg/l respectively in the neural tube defects group.MDA, CAT, GSH-Px and SOD levels were found as 0,84 nmol/ ml, 36 U/ml, 1,4 U/ml and 1,4 U/ml respectively in the control group; 0,9 nmol/ml, 32 U / ml, 2,7 U / ml and 1,4 U /ml respectively in the down syndrome group, 0,8 nmol/ ml, 28U / ml, 1,1 U/ml and 1,6 Ü/ml respectively in the neural tube defects group.There is no statisticaly difference among the three groups MDA, SOD and CAT levels(p > 0,05) but GSH-Px levels had difference among the groups (p
Benzer Tezler
- Amniyon sıvı incelenmesinde down sendromu tespit edilmiş gebelerde oksidan/antioksidan sistem, IL-6 ve IL-10 parametrelerinin değerlendirilmesi
Evaluation of oxidant / antioxidant system parameters, IL-6 and IL-10 levels in amniotic fluid of pregnancies with down sydrome
SEDA BAHSİ
Tıpta Uzmanlık
Türkçe
2014
BiyokimyaAnkara ÜniversitesiTıbbi Biyokimya Ana Bilim Dalı
PROF. DR. BERRİN İMGE ERGÜDER
- Toxoplasmosıs tanılı gebelerden alınan amniyon sıvılarından Toxoplasma gondii GRA4 geninin tanı ve immünizasyonda kullanılmak üzere izole edilmesi, klonlanması ve moleküler karakterizasyonu
Isolation, clonning and molecular characterisation GRA4 gene of Toxoplasma gondii obtained by amnion maies of pregnants who have toxoplasmosis
BEKİR TARTICI
Doktora
Türkçe
2020
ParazitolojiErciyes ÜniversitesiTıbbi Parazitoloji Ana Bilim Dalı
PROF. DR. ABDULLAH İNCİ
- Doğum yapmak üzere başvuran sağlıklı gebelerden doğum sırasında alınan amniyon mayi ve kord kanı örneklerinde tiroid hormon düzeylerinin karşılaştırılması
A comparison of the thyroid hormone levels in theamniotġc fluid and cord blood samples taken from healthypregnant women during delivery
ULYA ÜSKENT
Tıpta Uzmanlık
Türkçe
2018
Kadın Hastalıkları ve DoğumGazi ÜniversitesiKadın Hastalıkları ve Doğum Ana Bilim Dalı
PROF. DR. MEHMET ZEKİ TANER
- Prenatal tanıda sık görülen anöploidilerin multiplex ligation-dependent amplification (mlpa) yöntemi ile saptanması
Determining the common prenatal aneuploidies by using multiplex ligation-dependent amplification (mlpa) technique
HÜSEYİN YURDAKUL
Doktora
Türkçe
2007
Moleküler TıpEskişehir Osmangazi ÜniversitesiTıbbi Genetik Ana Bilim Dalı
DOÇ. M. HAMZA MÜSLÜMANOĞLU
Y.DOÇ. BEYHAN DURAK
- İkinci trimester tarama testi sonrasında amniyon sıvısı ve maternal kanda oksidatif stres değerlendirmesi
Evaluation of oxidative stress in amniotic fluid and maternal blood after the second trimester screening test
MAHMUT AKSİN
Tıpta Uzmanlık
Türkçe
2013
Kadın Hastalıkları ve DoğumHarran ÜniversitesiKadın Hastalıkları ve Doğum Ana Bilim Dalı
DOÇ. DR. MEHMET VURAL