Geniş alan BT taramalarında alan kenarlarında oluşan görüntü artefaktlarının radyoterapi planlamasında hesaplanan doza etkisi

Calculated dose impact of the image artifacts at the edges of the area from a wide-bore CT scans in radiotherapy treatment planning

  1. Tez No: 331284
  2. Yazar: AŞKIN AYDEMİR
  3. Danışmanlar: PROF. DR. SÜLEYMAN MEN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Radyoloji ve Nükleer Tıp, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Radyasyon dozajı, Radyografi, Radyoloji, Radyometri, Radyoterapi, Radyoterapi-bilgisayar yardımlı, Radiation dosage, Radiography, Radiology, Radiometry, Radiotherapy, Radiotherapy-computer assisted
  7. Yıl: 2012
  8. Dil: Türkçe
  9. Üniversite: Dokuz Eylül Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Medikal Fizik Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

BT tarayıcı cihazlarda görünen gantry açıklığı içerisinde standart görüntünün oluşturulduğu alan sFOV alanıdır. sFOV alanının dışında kalan alan genişleyen görüntünün oluşturulduğu eFOV alanıdır. eFOV alanına taşan objenin oluşturulan görüntüsü üzerinde sFOV alanı kenarlarında artefakt oluşmaktadır. Oluşan artefaktın bulunduğu bölgede BT numarası ve dış kontur distorsiyonu gibi sistematik hatalar meydana gelmektedir. Radyoterapi planlamasında kullanılan bu görüntülerde oluşan artefaktın hedef bölgeye iletilen radyasyon dozuna etkisi araştırılmıştır. Öncelikle BT cihazında mekanik kalibrasyon hatalarından olumsuz etkilenmemek için mekanik kalite kontrol testleri yapılmıştır. eFOV artefaktının görüntülenmesi, BT numarası ve kontur distorsiyonuna etkisinin incelenmesi için Mini QC BT fantom ile gantry merkezinde ve eFOV alanına girecek şekilde lateral kaydırılmış görüntüler elde edildi. eFOV artefaktının oluştuğu bölgede kontur ve BT numarası değişimi incelendi. Daha sonraki süreçte Alderson Rando fantom ile referans değerleri elde etmek için gantry merkezinde görüntüler elde edildi. eFOV alanına doğru ?x yönünde lateralde 8 cm ve ? x yönünde lateralde 12 cm' lik kaydırmalar ile görüntüler elde edildi. Bu görüntülere aynı eşik HU değerlerinde dış kontur, tedavi planlama sistemi tarafından çizdirildi. Yine alanında uzman hekimlerce ilgili kritik organ ve dokuları konturlandıktan sonra akciğer, prostat ve meme yerleşimli hayali tümörler oluşturuldu. Merkez yerleşimli görüntüler üzerine uygun tedavi planları yapıldı, uzman hekimlerce değerlendirilen tedavi planlarında hesaplanan MU değerleri, hayali tümör merkezinde ve medyanındaki doz değerleri not edildi. Lateral kaydırımlı görüntülerde aynı tedavi planı parametreleri kullanılarak aynı MU değerlerinde, hayali tümörlerin merkez ve meydanlarındaki doz değişimi incelendi. Referans alınan doz değerleri ile karşılaştırıldığında, lateral kaydırılan görüntü planlarında elde edilen doz değerlerinde pozitif yönde artış gözlenmiştir

Özet (Çeviri)

Mini QC CT phamtom were used to imaging eFOV artefact, centrally and partially outside the sFOV with laterally shift and to analyze effects of artefact on CT number distortion and body contour variation. CT number distortion and body contour variation were analyzed maximum artefact region. In the later period, Reference baseline images of Alderson Rando phantom were acquired with the phantom centrally positioned within the sFOV. For comparison, the phantom were then shifted laterally from the center of the phantom 8 cm and 12 cm, ? x direction. The phantom external body contours were then automatically created with a fixed threshold of HU value by the treatment planning system. Critical organs and tissues were contoured by expert doctors and fictitious tumors was delineated as the target, located lung, prastate and breast. The treatment plans for the center position images set was first generated and to evaluate by doctors. Calculated MU, center of the fictitious tumors dose values and tumor median dose values were recorded. The same MUs were used for the subsequent treatment plans for off-center image sets to ensure comparable amount of radiation delivery in each beam configuration plans. The target dose calculated at the center of the tumor and the calculated median tumor doses, were recorded and compared for all treatment plans. Compared with the dose values of located centrally images, the dose values of off-center image sets obtained from the positive direction is increased.

Benzer Tezler

  1. Holstein sığırında cavum nasi ve sinus paranasales'in kesitsel radyolojik ve 3B rekonstrüktif anatomisi

    Cross-sectional radiological and 3D reconstructive anatomy of the nasal cavity and paranasal sinuses in Holstein cattle

    NİMET TURGUT

    Doktora

    Türkçe

    Türkçe

    2021

    AnatomiSelçuk Üniversitesi

    Veterinerlik Anatomisi Ana Bilim Dalı

    PROF. DR. SADULLAH BAHAR

    DR. ÖĞR. ÜYESİ ABİDİN KILINÇER

  2. Prediction of COVID 19 disease using chest X-ray images based on deep learning

    Derin öğrenmeye dayalı göğüs röntgen görüntüleri kullanarak COVID 19 hastalığının tahmini

    ISMAEL ABDULLAH MOHAMMED AL-RAWE

    Yüksek Lisans

    İngilizce

    İngilizce

    2024

    Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve KontrolGazi Üniversitesi

    Bilgisayar Mühendisliği Ana Bilim Dalı

    PROF. DR. ADEM TEKEREK

  3. KÜNT TRAVMA SONRASI İZOLE KARACİĞER YARALANMASI OLAN HASTALARDA YARALANMA DERECESİNİ (GRADE) BELİRLEMEDE BİLGİSAYARLI TOMOGRAFİ VE KAN PARAMETRELERİNİN ETKİNLİKLERİNİN KARŞILAŞTIRILMASI

    COMPARISON OF THE EFFECTIVENESS OF COMPUTED TOMOGRAPHY AND BLOOD PARAMETERS IN DETERMINING THE INJURY GRADE IN PATIENTS WITH ISOLATED LIVER INJURY DUE TO BLUNT TRAUMA

    GİZEM AKBULUT

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2025

    Genel CerrahiBolu Abant İzzet Baysal Üniversitesi

    Genel Cerrahi Ana Bilim Dalı

    PROF. DR. MUSTAFA ŞİT

  4. Kafa travmalı geriatrik hastalarda prognozu etkileyen faktörlerin incelenmesi

    Investigation of the factors affecting the prognosis in elderly patients wi̇th HEAD trauma

    HASAN AYDIN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2016

    GeriatriDumlupınar Üniversitesi

    Acil Tıp Ana Bilim Dalı

    YRD. DOÇ. DR. HASAN ERÇELİK

  5. Application of different strategies to improve aerobic granular sludge process performance for treatment of municipal wastewater

    Kentsel atıksu arıtımında aerobik granüler çamur prosesinin arıtma performansını iyileştirmek için farklı stratejilerin uygulanması

    ŞADİYE KOŞAR

    Doktora

    İngilizce

    İngilizce

    2022

    Çevre Mühendisliğiİstanbul Teknik Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    DOÇ. MUSTAFA EVREN ERŞAHİN