Radyoterapide kullanılan video kamera tabanlı elektronik portal görüntüleme sistemlerinin kalite kontrolü ve elde edilen görüntülerin standartizasyonu

The quality control of video camera based electronic portal imaging systems used in radiotherapy and standardization of the obtained images

  1. Tez No: 344236
  2. Yazar: GİZEM BAKICIERLER
  3. Danışmanlar: PROF. DR. FADİME AKMAN, YRD. DOÇ. DR. HAKAN EPİK
  4. Tez Türü: Yüksek Lisans
  5. Konular: Onkoloji, Radyoloji ve Nükleer Tıp, Oncology, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: EPID, kalite güvenilirliği, kalite kontrol, modülasyon transfer fonksiyonu, uzaysal çözünürlük, kontrast, EPID, quality assurance, quality control, modulation transfer function, spatial resolution, contrast
  7. Yıl: 2013
  8. Dil: Türkçe
  9. Üniversite: Dokuz Eylül Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Medikal Fizik Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 99

Özet

Amaç: Bu çalışmada amaç, elektronik portal görüntüleme cihazının (EPID) kalite kontrolü için ?QC-3V? dijital fantom kullanılarak elde edilen görüntülerin PIPSpro yazılım programı ile analizini gerçekleştirmek ve veriler doğrultusunda cihazın görüntü performansını değerlendirmektir. Gereç ve Yöntem: Test görüntülerini elde etmek için fantom yerleşimi gantry 0° açısında EPID?in dedektör çerçevesi üzerinde ve izosentırda, 90°-270° gantry açılarında izosentırda olmak üzere dört ayrı set-up yapıldı. Siemens Primus lineer hızlandırcıya monte edilmiş video kamera tabanlı Siemens Beamview Plus EPID sisteminde ölçümler 30 gün boyunca tekrarlandı. Fantoma ait PIPSpro yazılımı ile port görüntülerinin otomatik analizi gerçekleştirildi. Analiz sonucunda bağıl modülasyon transfer fonksiyonu (RMTF), bölgelerdeki sinyal, kontrast gürültü oranı (CNR), uzaysal çözünürlük, bölgelerdeki standart sapma değerleri bir rapor olarak yazılım programı tarafından üretildi. Görüntü parametrelerinin incelenmesi sonucunda EPID cihazı performansı değerlendirildi. Bulgular: Gantry 0°?da, EPID üzerinde 6 MV foton enerjisi ile elde edilen a ve b görüntülerine ait ortalama RMTF_a ve RMTF_b değerleri sırasıyla 0.462(±0.360) ve 0.470(±0.360), 18 MV foton enerjisi ile ışınlamada 0.419(±0.400) ve 0.417(±0.370) hesaplandı. Izosentır üzerinde ise 6 MV foton enerjisi için ortalama RMTF değerleri 0.501(±0.360) ve 0.493(±0.370), 18 MV foton enerjisi ile ışınlamada 0.474(±0.360) ve 0.476(±0.410) hesaplandı. Gantry 90°?de, izosentır üzerinde 6 MV foton enerjisi için ortalama RMTF değerleri sırasıyla 0.487(±0.360) ve 0.490(±0.470), gantry 270°?de 0.490(±0.360) ve 0.484(±0.360) olarak saptandı. Fantomun ilgili bölgelerindeki alınan sinyal değerlerinin standart sapma ortalamaları değerlendirildiğinde bütün değerlerin ± %5 klinik kabul değerleri içerisinde olduğu tespit edildi. Fantomun EPID üzerine yerleştirilmesiyle 6 MV ve 18 MV için ortalama CNR ve çözünürlük değerleri sırasıyla 30.0(±4.5)-36.7(±8.3) ve 0.212-0.203 çizgi çifti/milimetre (çç/mm) olarak ölçüldü. Gantry 90° ve 270°?de fantomun izosentıra yerleştirilerek 6 MV foton enerijisi ile ışınlanmasıyla ortalama çözünürlük değeri sırayla 0.222 çç/mm ve 0.223 çç/mm bulundu. Sonuç: Doz hızı, ekran, ayna, kameranın bağıl hareketinin görüntü kalitesine bilinen etkisinin yanısıra yapılan çalışmada enerji, magnifikasyon, gantry rotasyon açısı ve birçok farklı faktörün etkisi görülmüştür. Bu nedenle EPID sistemlerinin iyi görüntü performansı için düzenli bir kalite kontrol programı gerekmektedir.

Özet (Çeviri)

Purpose: The purpose of this study is analyzing the images obtained by using?QC-3V? digital phantom by PIPSpro software program and evaluation the performance of the electronic portal imaging device (EPID) according to data. Material and Methods: For acquired test images four different set-ups were performed such as phantom location at gantry 0° angle, around the dedector of the EPID and at isocenter, at 90°-270° gantry angles isocenter. The measurements were performed for 30 days along at video camera based Siemens Beamview Plus EPID which is assembled to Siemens Primus linear accelator. Automatic analysis of portal images was performed by using PIPSpro software program which belongs to phantom. As a result of analysis relative modulation transfer function (RMTF), regional signals, contrast noise ratio (CNR), spatial resolution, the values of standard deviation in regions were generated as a report by software program. The performance of the EPID was evaluated as a result of examination of the image parameters. Results: At gantry 0° on the EPID with 6 MV photon energy the average value of RMTF_a RMTF_b which belong to a and b images was measured respectively as 0.462(±0.360) and 0.470(±0.360). On the other hand, at 18 MV photon energy exposure, the values were obtained as 0.419(±0.400) and 0.417(±0.370). At the isocenter the average RMTF value for the 6 MV photon energy was calculated as 0.501(±0.360) and 0.493(±0.370), for the 18 MV photon energy exposure the values were obtained as 0.474(±0.360) and 0.476(±0.410). At gantry 90° and at the isocenter the average RMTF for 6 MV photon energy was found as 0.487(±0.360) and 0.490(±0.470) respectively. For the gantry 270° the values were obtained as 0.490(±0.360) and 0.484(±0.360). When we evaluate the average standard deviation of signals from phantom regions, we can that all measurements are in ± %5 acceptable clinical value. By setting up the phantom on the EPID for 6 MV and 18 MV the average CNR and spatial resolution were measured as 30.0(±4.5)-36.7(±8.3) and 0.212-0.203 lp/mm respectively. At gantry 90°-270° by setting up the phantom at the isocenter with 6 MV photon energy exposure the average resolution values were maeasured as 0.222 lp/mm ve 0.223 lp/mm respectively. Conclusion: As we know the effect of dose rate, screen, mirror, relative movement of the camera on the quality of image, in this study the effect of energy, magnification, gantry rotation angle and different factors can be seen. Therefore, optimal display performance for EPID systems, quality control program is required on a regular basis.

Benzer Tezler

  1. Radyoterapi uygulamaları için otomatik iris lokalizasyonu

    Fully automated blink detection for uveal melanoma radiotherapy

    MELİH ÇAVUŞCULU

    Yüksek Lisans

    Türkçe

    Türkçe

    2017

    Elektrik ve Elektronik MühendisliğiTOBB Ekonomi ve Teknoloji Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    DOÇ. DR. İMAM ŞAMİL YETİK

  2. Videolaringoskopi ile entübe edilen obez ve obez olmayanhastaların vıdıac skorlarının değerlendirilmesi

    Evaluation of obese and NON-obese patients' intubated by videolaryngoscopy vidiac scores

    RIDVAN DURGUT

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2023

    Anestezi ve ReanimasyonSağlık Bilimleri Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    DOÇ. DR. NADİDE AYSUN POSTACI

    DOÇ. DR. AYÇA TUBA DUMANLI ÖZCAN

  3. Radyoterapide kullanılan yüksek enerjili foton dozimetrisinde berilyum oksit (BEO) optik uyarmalı lüminesans (OSL)'ın kalite kontrol amaçlı kullanılabilirliğinin araştırılması

    Investigation of the berrylium oxide (BEO) optical stimulated luminance (OSL) for quality control in high energy photon dosimetry used in radiotherapy

    ESİL KARA

    Doktora

    Türkçe

    Türkçe

    2023

    Fizik ve Fizik MühendisliğiAnkara Üniversitesi

    Medikal Fizik Ana Bilim Dalı

    PROF. DR. AYŞE HİÇSÖNMEZ

  4. Radyoterapide kullanılan koruyucu bloklar ile kurşun bilye ilaveli koruyucu blokların gama ışını geçirgenliklerinin karşılaştırılması

    The comparison of gamma ray transmissions of shielding blocks with lead marbles and shielding blocks used in radiotherapy

    NURAY YAVUZKANAT

    Yüksek Lisans

    Türkçe

    Türkçe

    2010

    Fizik ve Fizik MühendisliğiAnkara Üniversitesi

    Fizik Ana Bilim Dalı

    PROF. DR. AYŞE KAŞKAŞ

  5. Radyoterapide kullanılan lineer hızlandırıcıların fiziksel ve dozimetrik paratmetrelerinin karşılaştırılması

    The comparison of physical and dosimetric parameters of linear accelerators using in radiotherapy

    ALPER OĞUZ

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    Biyomühendislikİstanbul Üniversitesi-Cerrahpaşa

    Biyomedikal Mühendisliği Ana Bilim Dalı

    DOÇ. DR. AYSEL ERSOY YILMAZ