Karaciğer metastazlarında düşük dozlu perfüzyon BT'nin değişkenliği ve tekrarlanabilirliği

Liver metastases in the Low-Dose CT Perfusion Variability and Repeatability

  1. Tez No: 361447
  2. Yazar: OSMAN MELİH TOPCUOĞLU
  3. Danışmanlar: PROF. DR. MUSTAFA NASUH ÖZMEN
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Radyoloji ve Nükleer Tıp, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Karaciğer perfüzyon BT, karaciğer metastazı, çok düşük radyasyon dozu, Liver CT perfusion, liver metastases, very low radiation dose
  7. Yıl: 2014
  8. Dil: Türkçe
  9. Üniversite: Hacettepe Üniversitesi
  10. Enstitü: Tıp Fakültesi
  11. Ana Bilim Dalı: Radyoloji Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 81

Özet

Tümör dokusunun bölgesel ve global perfüzyonunu kalitatif ve kantitatif olarak değerlendirme olanağı sağlayan karaciğer perfüzyon BT tetkiki son yıllarda giderek artan bir sıklıkla kullanılmaya başlanmıştır. Ancak elde edilen parametrelere ait ölçümlerin tekrarlanabilir olup olmadığı ve farklı değerlendiriciler arasında ölçümlerin çok değişkenlik gösterebilmesi bu konuya yönelik araştırma yapılarak bu noktanın açıklığa kavuşturulmasını gerektirmiştir. Ayrıca diğer perfüzyon BT tetkiklerinde olduğu gibi karaciğer perfüzyon BT için de en önemli sorun yüksek radyasyon dozlarıdır. Bu bilgilerden yola çıkılarak, bu çalışmanın amacı çok düşük efektif doz ile yapılan karaciğer perfüzyon BT incelemesine ait parametre ölçümlerinin farklı okuyucular arasındaki ve okuyucuların kendi içlerindeki uyumluluğunu (değişkenliğini) ve tekrarlanabilirliğini araştırmaktır. Bu amaçla adaptif 4 boyutlu spiral modda çift tüplü 64 dedektörlü birinci jenerasyon BT cihazı (Definition, Siemens Medical Systems; Erlangen, Germany) kullanılarak karaciğer metastazı saptanan ve kemoterapi almamış 22 hastaya kemoterapi öncesi ve sonrası nefes tutturulmaksızın 53 adet perfüzyon BT tetkiki yapıldı. Elde edilen perfüzyon parametrelerine ait ölçümler iki farklı radyolog tarafından özgün bir yazılım eşliğinde birbirlerinden bağımsız olarak ikişer kez yapıldı. Radyologlar arasında ve kendi içlerindeki ölçümlerde en az değişkenlik gösteren parametreler BF ve BV idi. Bu değerler için istatistiksel olarak anlamlı fark saptanmadı. Permeabilite, ALP, PVP ve HPI parametreleri ise çok fazla değişkenlik göstermekteydi. Yapılan tüm karaciğer perfüzyon BT tetkiklerine ait efektif doz 2,9 mSv idi. Çok düşük dozda yapılan karaciğer perfüzyon BT tetkiki tedaviye yanıt değerlendirme amacıyla tekrarlayan perfüzyon incelemeleri gerektiren kanser hastalarında kullanılabilir. Ancak güvenli klinik uygulama için, çok düşük doz karaciğer pBT, terapötik yanıtın değerlendirilmesinde üzerinde düşünülmesi ve dikkatli yorumlanması gereken bir yöntemdir. Yine de tedaviye yanıtı değerlendirmek amacıyla pBT yapılacaksa pozitif ya da negatif yanıt kararı verilirken BF ve BV değerlerinin kullanılması daha uygun gözükmektedir.

Özet (Çeviri)

Hepatic perfusion CT enabling qualitative and quantitative assessment of the regional and global tumoral perfusion, have been used increasingly in recent years. However quite variability of the parameter measurements obtained by the hepatic perfusion CT leads and forces radiologists to make researches on this issue. The most important handicap for hepatic perfusion CT as the other perfusion CT examinations is the high radiation doses. With these backround knowledge the aim of this study is to determine the intra- and interobserver agreement on the perfusion measurements of very low dose hepatic perfusion CT. For this purpose 53 perfusion CT examinations were performed from 22 patients with liver metastasis from various primary cancers. Perfusion CT images obtained with a dual-source 64-row multidetector CT scanner (Definition, Siemens Medical Systems; Erlangen, Germany) in adaptive 4D spiral mode without breath-holding. Obtained perfusion parameters were prospectively analyzed by two different readers independently twice. The least variable parameters between the readers were BF and BV. There was no statistically significant diffence with these measurements. However, permeability, ALP, PVP and HPI were quite variable between readers and between reads. The effective doses of all perfusion CT studies were 2,9 mSv. Very low dose hepatic perfusion CT can be utilized for assessing therapy response in cancer patients requiring multiple recurrent perfusion examinations. However for reliable clinical applications very low dose hepatic perfusion CT should be addressed and interpreted carefully in deciding response to the therapy. Nevertheless if perfusion CT is performed for assessing therapy response, BF and BV measurements seem to be more appropriate for deciding positive or negative response.

Benzer Tezler

  1. Böbrek üstü bezi metastazlarında stereotaktik beden radyoterapisinin hedef hacim doz homojenitesine etkisinin değerlendirilmesi

    Evaluation of the target volume dose homogeneity of stereotactic body radiotherapy in adrenal gland metastasis

    HAMZA TATLI

    Yüksek Lisans

    Türkçe

    Türkçe

    2012

    Fizik ve Fizik MühendisliğiAnkara Üniversitesi

    Medikal Fizik Ana Bilim Dalı

    DOÇ. DR. BAHAR DİRİCAN

  2. Kolorektal kanser karaciğer metastazlarında yttrium-90 cam mikroküreler ile uygulanan selektif internal radyoterapide mikroküre sayısı ve kalibrasyon zamanı ile doz-yanıt ilişkisi

    Dose-response analyses for microsphere number and calibration time in selective internal radiotherapy with yttrium-90 glass microspheres in patients with colorectal cancer liver metastases

    SELİN KESİM

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2022

    Radyoloji ve Nükleer TıpMarmara Üniversitesi

    Nükleer Tıp Ana Bilim Dalı

    PROF. DR. HALİL TURGUT TUROĞLU

  3. Kolorektal kanser karaciğer metastazlarında yttrıum 90 ile radyoembolizasyonun orta ve uzun dönem etkinliğinin değerlendirilmesi

    Evaluation of mid term and long term efficacy of radioembolization with yttrium 90 in liver dominant colorectal metastases

    GAMZE TÜRK

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2015

    OnkolojiHacettepe Üniversitesi

    Radyoloji Ana Bilim Dalı

    PROF. DR. BORA PEYNİRCİOĞLU

  4. Meme kanserinde Tc-99m V-DMSA (Pentavalan-Dimerkaptosüksinik Asid) sintigrafisi ile F-18 FDG PET/BT çalışmalarının karşılaştırılması ve sintigrafik çekimler esnasında meme yastığı ile pozisyonlanmış ve pozisyonlanmamışgörüntülerin karşılaştırılmalı değerlendirilmesi

    Comparison of Tc-99m V-DMSA scintigraphy and F-18 FDG PET/CT in breast cancer and evaluation of scintigraphic images obtained with and without breast positioining

    SEZEN ELHAN VARGÖL

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2014

    Radyoloji ve Nükleer TıpHacettepe Üniversitesi

    Dahili Tıp Bilimleri Bölümü

    PROF. DR. ESER LAY ERGÜN

  5. Rektum kanserinde Ga-68 FAPİ-04 PET/BT'nin evreleme ve prognoz belirlemeye katkısı

    The contribution of Ga-68 FAPI-04 PET/CT to staging and prediction of prognosis in rectal cancer

    ÖZGE EROL FENERCİOĞLU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2024

    Radyoloji ve Nükleer TıpSağlık Bilimleri Üniversitesi

    Nükleer Tıp Ana Bilim Dalı

    PROF. DR. NURHAN ERGÜL