Geri Dön

Kavite dezenfeksiyonu amacıyla kullanılan farklı antimikrobiyal solüsyonların ve lazer sistemlerinin siloran bazlı kompozitlerin tamir dayanımı üzerine etkisi

Influence of different cavity disinfection solutions and laser systems on repair bond strength of silorane based composites

  1. Tez No: 365375
  2. Yazar: ALPER KAPDAN
  3. Danışmanlar: DOÇ. DR. FERİDUN HÜRMÜZLÜ
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2014
  8. Dil: Türkçe
  9. Üniversite: Cumhuriyet Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Restoratif Diş Tedavisi ve Endodonti Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 103

Özet

Çalışmamızın amacı siloran bazlı kompozit restoratif materyallerinin tamir dayanımı üzerine, antibakteriyel etkileri sebebiyle kullanılan ozonlu su, klorhekzidin, Er:YAG lazer ve Nd:YAG lazer uygulamalarının yaşlandırma öncesi ve sonrası etkilerini incelemek ve örnekleri Taramalı Elektron Mikroskobu (Scaning Electron Mycroscope (SEM) ) ile değerlendirmektir. Çalışmamızda kullanılmak üzere oluşturulan akrilik bloklar üzerinde 100 adet kavite hazırlandı. Bu kaviteler siloran bazlı kompozitle dolduruldu. Bütün örnekler termal siklus cihazında bekletildi (5-55 ºC de 5000 devir). Sonrasında her bir grupta 20 örnek olacak şekilde 5 gruba ayrıldı. Grup 1: Klorhekzidin; Grup 2: Ozonlu; Grup 3: Nd:YAG lazer; Grup 4: Er:YAG lazer; Grup 5: Herhangi bir dezenfektan uygulanmayan kontrol grubu. Kontrol grubu dışındaki örneklere dezenfeksiyon işlemleri uygulanıp, kompozit tamir işlemi yine aynı marka siloran bazlı kompozit ve bu kompozite ait adeziv sistemi ile gerçekleştirildi. Tamir işlemi bitirilen gruplar 2 alt gruba ayrıldı. Her bir gruba ait alt gruplardan bir tanesi tekrar termal siklus cihazında bekletildi (5-55 °C de 5000 devir). Termal siklusa tabi tutulmayan alt gruplar 24 saat distile suda bekletildikten hemen sonra, diğerleri ise termal siklus sonrası makaslama bağlanma dayanımı testi için üniversal test cihazında test edildi. Elde edilen değerler istatistiksel olarak analiz edildi. Deney grupları arasında termal siklus öncesi ve termal siklus sonrası makaslama bağlanma değerleri arasında fark olup olmadığı Varyans analizi, her bir grupta termal siklus öncesi ve termal siklus sonrası makaslama bağlanma değerleri arasında ki fark ise Student t kullanılarak analiz edildi. Makaslama testi uygulanan kırık örnekler 40X büyütmede stereomikroskop altında incelendi ve kopma tipleri; adeziv, restorasyonda koheziv, tamir kompozitinde koheziv ve karışık tipte kopma yüzeyi olarak sınıflandırıldı. Ayrıca her bir gruptaki örnekler SEM ile incelendi. Yapılan istatistiksel değerlendirmeler sonucunda ilk termal siklus uygulamasından sonraki değerlendirmede tüm gruplar arasında makaslama bağlanma kuvveti açısından istatistiksel olarak bir fark gözlenmemiştir (p>0,05). Kompozit tamir işlemi uygulandıktan sonra tekrar termal siklus işlemine tabi tutulan tüm gruplar arasında tamir makaslama bağlanma kuvveti değerleri açısından istatistiksel olarak anlamlı bir fark gözlenmemiştir (p>0,05). Tamir işlemi yapıldıktan sonra termal siklus öncesi ve sonrası karşılaştırmada her bir grup kendi içerisinde değerlendirildiğinde; Ozonlu su, Nd:YAG, Er:YAG ve Kontrol gruplarının tamir makaslama bağlanma kuvveti değerlerinde istatistiksel olarak anlamlı bir fark gözlenmezken (p>0,05), sadece Klorhekzidin grubunda termal siklus uygulaması sonrası tamir makaslama bağlanma kuvveti değerlerinde istatistiksel olarak anlamlı bir azalma gözlenmiştir (p

Özet (Çeviri)

The aim of our study is to examine the effects on before and after the aging of Nd: YAG laser, Er: YAG laser, chlorhexidine practices and ozonated water practice which is used for the purpose of the antibacterial effects, on repair resistance of silorane based composite restorative materials and to evaluate the samples with Scanning Electron Microscope (SEM). 100 cavities had been prepared on acrylic blocks created to be used in our study. Those cavities had been filled with silorane based composite. All of the samples had been waited on the thermal cycle device (5000 cycles at 5-55 °C). Afterwards, they had been separated to 5 groups by having 20 samples in each group. Group 1: The chlorhexidine practice; Group 2: The ozonated water practice; Group 3: Nd:YAG laser practice; Group 4: Er:YAG laser practice; Group 5: The control group where no disinfectants are applied. The disinfection operations had been made to the samples except the ones in the control group, and the composite repair operation had been implemented with the same brand silorane based composite and the adhesive system of this composite. The groups with finished repair operation had been separated into 2 sub groups. One of the sub groups that belong to each group had waited in the thermal cycle device again (5000 cycles at 5-55°C). The sub groups which were not subjected to the thermal cycle had been put into the universal test vehicle for attachment with shears resistance test just after being waited in the water for 24 hours, and for the others, after the thermal cycle and the test operation had been implemented. Those values had been analyzed statistically. The variance analysis had been used for searching whether there were any differences or not among the attachment with scissors values before and after the thermal cycle between the experiment groups. The significance test (Student t) of the difference between the two averages on the independent groups had been used while searching of whether there were any differences among the attachment with shears before and after the thermal cycle in each group. The broken samples which were implemented on the shearing test had been examined under the stereomicroscope with 40X extension and the split types had been classified as adhesive, cohesive on the restoration, cohesive on the repair composition and split surface on the mixed type. In addition, the samples in each group had been examined with SEM (Scanning Electron Microscope). In the result of statistical evaluations, no statistical difference had been observed among every groups in terms of shear bond strength on the evaluation after the first thermal cycle operation (p>0,05). After the composite repair operation had been applied, no statistically significant difference had been observed among every groups that were subjected to re-thermal cycle operation in terms of repair shear bond strength values (p>0,05). When each group had been evaluated in themselves on comparing before and after the thermal cycle after the repair operation; as no statistically significant difference had been observed on the repair shear bond strength values of the Ozonated water, Nd:YAG, Er:YAG and Control groups (p>0,05), a statistically significant decrease had been observed only in the Chlorhexidine group on the values of repair shear bond strength after the thermal cycle application (p

Benzer Tezler

  1. Geleneksel kavite dezenfektanı ve ozonun, güncel restoratif materyal uygulanmış dişlerde makaslama bağlanma dayanımına etkisi

    The effect of traditional cavity disinfectant and ozone on the shear bond strength in current restorative materials applied teeth

    YASEMİN YAVUZ

    Doktora

    Türkçe

    Türkçe

    2015

    Diş HekimliğiDicle Üniversitesi

    Diş Hastalıkları ve Tedavisi Ana Bilim Dalı

    DOÇ. DR. EMRULLAH BAHŞİ

  2. Effect of different precursors and disinfection processes on the formation of nitrosamines

    Nitrosamin oluşumunda farklı öncü maddelerin ve dezenfeksiyon proseslerinin etkisi

    BURÇİN COŞKUN

    Doktora

    İngilizce

    İngilizce

    2023

    Mühendislik Bilimleriİstanbul Teknik Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    PROF. DR. ELİF PEHLİVANOĞLU MANTAŞ

  3. Effects of cold plasma treatment on the quality andantioxidant properties of mixed fruit juice

    Soğuk plazma uygulamasının karışık meyve suyunun kaliteve antioksidan özelliklerine etkileri

    ECRE ŞAHİNOĞLU

    Yüksek Lisans

    İngilizce

    İngilizce

    2023

    Gıda Mühendisliğiİstanbul Teknik Üniversitesi

    Gıda Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ CELALE KIRKIN GÖZÜKIRMIZI

  4. Tavuk kesimhane ve işletmelerinde kullanılan ticari dezenfektanların etkinliklerinin belirlenmesi

    Determination of efficacy of commercial disinfectants used in poultry slaughterhouses

    AYLA ŞENER

    Yüksek Lisans

    Türkçe

    Türkçe

    2003

    Gıda MühendisliğiHacettepe Üniversitesi

    Gıda Mühendisliği Ana Bilim Dalı

    PROF. DR. AYHAN TEMİZ

  5. Farklı su kaynaklarında ve şebekelerde karbonlu ve azotlu dezenfeksiyon yan ürünlerinin oluşumu

    Formation of carbonaceous and nitrogenous disinfection by products in different water sources and distribution systems

    CİHAN ÖZGÜR

    Doktora

    Türkçe

    Türkçe

    2019

    Çevre MühendisliğiSüleyman Demirel Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    DOÇ. DR. ŞEHNAZ ŞULE KAPLAN BEKAROĞLU