Photothermal ablation of liver tissue with 1940-nm thulium fiber laser: Ablation efficiency and temperature measurements

1940-nm tulyum fiber laserin karacığer doku fototermal ablasyon: Ablasyon verimliliği ve sıcaklık ölçümleri

  1. Tez No: 392544
  2. Yazar: HEBA ALAGHA
  3. Danışmanlar: PROF. DR. MURAT GÜLSOY
  4. Tez Türü: Yüksek Lisans
  5. Konular: Biyomühendislik, Bioengineering
  6. Anahtar Kelimeler: Lazer tedavisi, Laser therapy
  7. Yıl: 2015
  8. Dil: İngilizce
  9. Üniversite: Boğaziçi Üniversitesi
  10. Enstitü: Biyomedikal Mühendislik Enstitüsü
  11. Ana Bilim Dalı: Biyomedikal Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmanın amacı 1940-nm Tulyum fiber laserin karaciğer cerrahisinde etkinliğini araştırmaktır. Bu amaçla çeşitli çalışma yöntemleriyle ve farklı güçlerde uygulanan 1940-nm Tulyum fiber laserin karaciğer dokusu üzerindeki ablasyon etkinliği belirlendi. Laser uygulamaları esnasında gerçek zamanlı sıcaklık ölçümü geri besleme tekniği ile laser parametrelerini düzenlemek için kullanıldı ve çevre dokularda oluşan ısıl hasar en aza indirgendi. Bu çalışmada taze kuzu karaciğer dokuları kullanıldı. Laser ışıması, 400 µm merkez çapa sahip olan çıplak uçlu optik lifler ile doku örneklerine temas ettirilerek aktarıldı. Laser uygulamaları sürekli dalga ve darbeli şekillerde, farklı süre ve güçlerde (200, 400, 600 ve 800 mW) yapıldı. Uygulama süreleri karşılaştırmada kolaylık sağlaması amacıyla her güç seviyesinde 4 J'lik enerji dozu verilecek şekilde belirlendi. Laser uygulamalarının ardından dokular H&E ile boyanarak histolojik inceleme sonucunda ablasyon ve toplam değişim alanları değerlendirildi ve ablasyon etkinliği hesaplandı. Çevre dokuların sıcaklığı uygulama alanından 1 mm uzaklıkta dokunun içine yerleştirilen K-tipi bir ısıl-çift kullanılarak ölçüldü ve sıcaklık değişim hızı hesaplandı. Sıcaklık değişim hızı ile ablasyon bölgeleri arasında güçlü korelasyon görüldü. Hem sürekli dalga hem de darbeli şekillerde yapılan yüksek güç seviyesindeki uygulamalarda daha büyük ablasyon ve toplam değişim alanları elde edilse de ablasyon etkinliğinde önemli bir fark ortaya çıkmadı. Sürekli dalga uygulamalarında darbeli uygulamalara kıyasla daha büyük ablasyon ve toplam değişim alanlarına ve daha yüksek ablasyon etkinliklerine ulaşıldı. Histolojik değerlendirmeyle yüksek güçlü uygulamalarda dar bir kofullaşma (vakuollaşma) alanı ve önemsiz seviyede karbonizasyon gözlemlenmiştir.

Özet (Çeviri)

The purpose of this study was to investigate the effectiveness of 1940-nm Thulium fiber laser for liver surgery. This was done by determining the ablation efficiency of different working modes and power settings of 1940-nm Thulium fiber laser on liver tissue, in addition to utilizing a real time temperature monitoring to provide the necessary feedback for adjusting laser parameters to minimize the collateral thermal damage to adjacent tissues. Thulium fiber laser was delivered to lamb liver tissue samples via 400 $\mu$m flat-cut bare-ended tip fiber in contact mode. Continuous-wave and pulsed modes were used, each at 4 different laser power values (200, 400, 600, and 800 mW) and exposure times. Exposure times were chosen to give the same total applied energy of 4J for comparison purposes. A total of 64 laser applications were performed in order to study 8 laser parameter combinations with each parameter combination repeated 8 times. Following laser irradiation, tissues were processed and stained with H\&E for macroscopic evaluation of ablation and total altered areas, and ablation efficiencies were calculated. Temperature of the nearby tissue was measured using a K-type thermocouple that was inserted at a distance of 1 mm from the fiber, and rate of temperature change was calculated. A strong correlation between the rate of temperature change and ablation area was depicted. Larger ablation and total altered areas were obtained for higher power values for both continuous-wave and pulsed modes, while ablation efficiencies were not significantly different. Continuous mode yielded higher ablation and total altered areas, and higher ablations efficiencies than pulsed mode. Histological evaluation revealed a narrow vacuolization zone and negligible carbonization for higher power values.

Benzer Tezler

  1. Kinetics of free radical bulk polymerization of methyl methacrylate

    Başlık çevirisi yok

    EMİNE ELİF HAMURCU GÜREL

    Yüksek Lisans

    İngilizce

    İngilizce

    1990

    Boğaziçi Üniversitesi

    Yükleniyor...

  2. Uydu verileri ile İstanbul Boğazı ve Haliç'de su kirliliğinin makro düzeyde belirlenmesi

    Intrepretation at macro level as pollution of water resources of remotely sensed data of Bosphorus and golden horn estuary by an unsupervised and supervised classification method

    H.GONCA COŞKUN

    Doktora

    Türkçe

    Türkçe

    1992

    İstanbul Teknik Üniversitesi

    Yükleniyor...

  3. Preparation and characterization of silicon thin films

    Silisyum ince filmlerinin hazırlanması ve karakterizasyonu

    İSMAİL ATILGAN

    Doktora

    İngilizce

    İngilizce

    1993

    Orta Doğu Teknik Üniversitesi

    Fizik Ana Bilim Dalı

    Yükleniyor...

  4. Mikroişlenmiş ivme ölçer üretimi ve optimizasyonu

    Fabrication and optimization of micro machined accelerometers

    MEHMET MURAT OKYAR

    Yüksek Lisans

    Türkçe

    Türkçe

    1994

    İstanbul Teknik Üniversitesi

    Yükleniyor...

  5. Uydu verilerinden harita kapsamında görüntü üretmenin geometrik doğruluğu

    The Geometric accuracy of producing a map scene from satellite image data

    CENGİZHAN İPBÜKER

    Yüksek Lisans

    Türkçe

    Türkçe

    1994

    İstanbul Teknik Üniversitesi

    Yükleniyor...