Geri Dön

Birleşik bilgisayarlı tek foton emisyon tomografisi/bilgisayarlı tomografi (SPECT/CT) ile birleşik pozitron emisyon tomografisi/bilgisayarlı tomografi (PET/CT) sistemlerinde tomografik görüntülere sistem yazılım parametrelerinin etkisinin incelenmesi

Investigation of the system software parameters effects on the tomographic images in the combined single photon emission computed tomography/ computed tomography (SPECT/CT) and combined positron emission tomography/ computed tomography (PET/CT) systems

  1. Tez No: 406422
  2. Yazar: HIKMAT OSMAN
  3. Danışmanlar: DOÇ. DR. TURAN OLĞAR
  4. Tez Türü: Yüksek Lisans
  5. Konular: Radyoloji ve Nükleer Tıp, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2015
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Nükleer Bilimler Enstitüsü
  11. Ana Bilim Dalı: Medikal Fizik Ana Bilim Dalı
  12. Bilim Dalı: Sağlık Fiziği Bilim Dalı
  13. Sayfa Sayısı: 159

Özet

Nükleer Tıp görüntüleri organ fonksiyonlarının saptanması ile ilgili önemli bilgi sağlar. Bilgisayarlı Tek Foton Emisyon Tomografi (Single Photon Emission Computed Tomography, SPECT) ve Pozitron Emisyon Tomografisi (Positron Emission Tomography, PET) sistemleri bu amaç için kullanılan başlıca sistemlerdir. Nükleer tıp uygulamalarında hastalığın doğru teşhisini sağlayan optimum görüntü kalitesi için bu sistemlerin kalite kontrol ve performans testlerinin yapılması gereklidir. Bu çalışmanın amacı, nükleer tıp görüntüleme sistemlerinde kullanılan tomografik görüntü oluşturma yöntemleri ve görüntü işleme parametrelerinin görüntü kalitesine etkisinin araştırılmasıdır. Bu amaç doğrultusunda tomografik görüntüler, bir SPECT ve bir PET sistemi kullanılarak farklı performans ölçüm fantomları (Jaszczak, Hoffman 3-D Beyin Fantomu) aracılığıyla filtre geriye projeksiyon (Filtered Back Projection, FBP) ve tekrarlayıcı (3D-Ordered Subset Expectation Maximization, OSEM) kesit görüntüsü elde etme yöntemleri ve farklı görüntü işleme parametreleri (filtre, tekrar sayısı, alt grup sayısı, filtre genişliği ve büyütme faktörü) kullanılarak oluşturulmuştur. Foton azalım düzeltmesi için, SPECT ve PET sistemleri ile birleşik olarak kullanılan bilgisayarlı tomografi (BT) sistemlerinden elde edilen transmisyon görüntüleri kullanılmıştır. Farklı parametre ile oluşturulmuş her görüntü üzerinde % rms, kontrast, homojenite, kontrast gürültü oranı (Contrast to Noise Ratio, CNR), radyoaktif tutulum oranı (Radioactivity Concentration Ratio, RCR)ve tomografik uzaysal ayırma gücü (FWHM) ölçülmüştür. Ölçümler sonucunda, uzaysal ayırma gücünün ve kontrastın PET sisteminde SPECT sistemine göre daha yüksek olduğu, 3D-OSEM tekrarlayıcı teknikte ise 4-6 tekrar ve 8-16 alt grup seçiminin kabul edilebilir bir görüntü kalitesi için optimum olduğu sonucuna varılmıştır.

Özet (Çeviri)

Nuclear medicine images provides important information about metabolic abnormality of the organs. SPECT and PET systems are the main imaging systems using for this purpose. Quality control and performance tests of these systems are necessary for the optimum image quality required for correct diagnosis in nuclear medicine applications. The aim of this study is to investigate effect of tomographic image reconstruction methods and different image processing algorithms on tomographic image quality. for this purpose, tomographic images were reconstructed by using both filtered back projection and 3D-OSEM tomographic images reconstruction methods and different image processing parameters like filter, iteration number, subset number, filter width and zoom factor and different performance measurement phantoms (Jaszczak, Hoffman 3D- Brain phantom) for each SPECT and PET imaging systems. For foton attenuation correction in both SPECT and PET, CT transmission images were used. Relative noise (% rms – %root mean square), contrast, homogeneity, contrast- noise ratio (CNR), radioactivity concentration ratio and spatial resolution were measured for each tomographic image formed by using different prameters. As a result of the measurements, the spatial resolution and contrast in the PET system were better than that in SPECT system and 4-6 iterations and 8-16 subsets for 3D-OSEM method were observed as the optimum choice for acceptable image quality.

Benzer Tezler

  1. 99mTc ile işaretli madecassoside ve enkapsüle edilmiş madecassoside bileşiklerinin sentezi ve parkinson hastalığının teşhisinde kullanılabilirliğinin ın vitro/ın vivo yöntemlerle tespiti

    The synthesis of encapsulated madecassoside and radiolabeled madecassoside with 99mTc and the determination the availability of utilizing in diagnosis of parkinson's disease with in vitro / in vivo methods

    EMRE UYGUR

    Doktora

    Türkçe

    Türkçe

    2020

    Nükleer MühendislikEge Üniversitesi

    Nükleer Bilimler Ana Bilim Dalı

    PROF. DR. FAZİLET ZÜMRÜT BİBER MÜFTÜLER

  2. Medikal radyoizotop üretimi için nükleer model hesaplamaları ve veri elde edilmesi

    Nuclear model calculations and data obtaining for production of medical radioisotopes

    OZAN ARTUN

    Doktora

    Türkçe

    Türkçe

    2015

    Nükleer MühendislikBülent Ecevit Üniversitesi

    Fizik Ana Bilim Dalı

    PROF. DR. HÜSEYİN AYTEKİN

  3. Modulation response of A 1.55 mm InGaAsP semiconductor laser diode

    Yarı iletken 1.55 mm InGaAsP lazer diyodunun modülasyon tepkisi

    M.EMİN TAĞLUK

    Yüksek Lisans

    İngilizce

    İngilizce

    1992

    Elektrik ve Elektronik MühendisliğiGaziantep Üniversitesi

    DOÇ. DR. M. S. ÖZYAZICI

  4. Gamma-ray detector array

    Gama ışını algılayıcısı serisi

    EKREM OĞUZHAN ANGÜNER

    Yüksek Lisans

    İngilizce

    İngilizce

    2008

    Fizik ve Fizik Mühendisliğiİstanbul Teknik Üniversitesi

    Fizik Bölümü

    DOÇ. DR. CENAP Ş. ÖZBEN

  5. Equimolar binary compounds: A first-principles based machine learning study

    Eşmolar ikili alaşımlar: AB-initio tabanlı makina öğrenme çalışması

    CEM ORAN

    Yüksek Lisans

    İngilizce

    İngilizce

    2021

    Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve Kontrolİstanbul Teknik Üniversitesi

    Hesaplamalı Bilimler ve Mühendislik Ana Bilim Dalı

    PROF. DR. ADEM TEKİN