Dijital radyografik görüntüleme sistemlerinde görüntü kalitesi metriklerinin incelenmesi ve metriklerin hesaplanması için yazılım geliştirilmesi

Investigation of image quality metrics for digital radiograhic imaging systems and software development for calculation of these metrics

  1. Tez No: 406421
  2. Yazar: AZİZ RASİM YUSUF
  3. Danışmanlar: YRD. DOÇ. DR. ÖZLEM BİRGÜL
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Physics and Physics Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2015
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Nükleer Bilimler Enstitüsü
  11. Ana Bilim Dalı: Medikal Fizik Ana Bilim Dalı
  12. Bilim Dalı: Sağlık Fiziği Bilim Dalı
  13. Sayfa Sayısı: 146

Özet

Dijital sistemler son yıllarda radyolojik incelemelerde sıklıkla kullanılmaya başlanmıştır. Bu sistemlerin avantajlarından biri, dijital ortamda görüntü işleme yapılabilir olması ve buna bağlı olarak görüntü kalitesi ve sistem performansının nicel olarak hesaplanabilmesidir. Bu amaca yönelik olarak bu metriklerin hem görüntü üzerinde hem de frekans uzayında hesaplanması mümkündür. Geçtiğimiz yıllarda bu amaçla Nükleer Bilimler Enstitü bünyesinde NBEGKY adında modüler bir yazılım geliştirilmiştir (Üncü 2013). Bu tez çalışmasında, görüntü kalitesi, dedektör performansı ve gürültü karakteristiğinin hesaplanmasına yönelik olarak yeni algoritmalar gerçekleştirilmiştir ve araçlar hazırlanmıştır. Bu algoritmaları sistemlerin doğrusal doz yanıtına sahip olduğunu varsaymaktadır. Öncelikle doğrusal olmayan sistemler için düzeltme yapan STPTool geliştirilerek doz yanıtı ile ilgili katsayıları hesaplanmıştır. Görüntü kalitesi metriklerinden Modülasyon Transfer Fonksiyonu (modulation transfer function, MTF) hesaplamasında önceki yazılımda kullanılan IEC yöntemine ek olarak yeni bir yöntem eklenmiş ve iki yöntem kıyaslanmıştır. Yöntem parametrelerinin kontrol edilebileceği ve hesaplamaların yapıldığı bir MTFTool geliştirilmiştir. Görüntüdeki gürültünün frekans uzayında hesaplanması için NNPS Tool aracı hazırlanmıştır. Normalize Gürültü Güç Spektrumunun (normalized noise power spectrum, NNPS) hesaplanmasında kullanılan parametrelerin spektrum üzerindeki etkileri incelenmiştir. Geliştirilen araçlar farklı yazılımlar ile kıyaslanmıştır. Dedeksiyon Kuantum Verimliliği (detection quantum effieciency, DQE) ve etkin dedeksiyon kuantum verimliliği (eDQE) gibi dedektör ve sistem performansı metriklerinin hesaplanması için DQE/eDQETool aracı geliştirilmiştir. Saçılım kesrinin hesaplanması için BeamStopEvaluator aracı oluşturulmuş ve fantom değerlendirilmesi modülüne eklenmiştir. Yeni hazırlanan modüllerin yanı sıra yazılımın arayüzü de yeniden tasarlanmıştır. Son olarak geliştirilen yazılımın kullanım kılavuzu yazılmıştır.

Özet (Çeviri)

In recent years, digital systems has been used frequently in radiological examinations. One advantage of these systems is the possibility of using digital image processing tools, and accordingly, calculation of image quality and system performance quantitatively. It is possible to calculate these metrics both on the image itself and on its frequency domain representation. For this purpose, a software was developed within our Institute of Nuclear Sciences in the past with certain capabilities (Üncü 2013). In this study, new algorithms were implemented and new tools were developed to evaluate the image quality, detector performance and noise characteristics. These algorithms assume that the system dose response is to be linear. For nonlinear systems, dose response is characterized and coefficients were calculated using the STPTool developed within the thesis work. In addition to the IEC method used in the former software, a new method has been added to calculate one of image quality metrics, namely the Modulation Transfer Function (MTF) and two methods were compared. To calculate and control the parameters used in algortihms, MTFTool has been developed. NNPS Tool is designed to calculate the noise in frequency space. Parameters used that effect in calculation of Normalized Noise Power Spectrum (NNPS) were examined. Developed tools has been compared with different softwares. For calculating detector performance, detection quantum efficiency (DQE) and for determining the overall system performance, effective detection quantum efficiency (eDQE) were used. DQE/eDQETool was developed to calculate these metrics. For finding the scatter fraction, Beam Stop Evaluator was developed and added to the phantom evaluation module. In addition to new modules, software interface was redesigned. Finally, the software developed manual was prepared.

Benzer Tezler

  1. Farklı dijital radyografi sistemlerinin kontrast-ayrıntı dedeksiyonu ve dedeksiyon kuantum etkinliği (DQE) açısından karşılaştırılması

    Comparison of different digital radiography systems in terms of contrast-detail detectability and detective quantum efficiency (DQE)

    TUĞBA ÇELİK

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    Fizik ve Fizik MühendisliğiAnkara Üniversitesi

    Medikal Fizik Ana Bilim Dalı

    DOÇ. DR. TURAN OLĞAR

  2. Film-ekran, dijitize film-ekran ve dijital radyografi sistemlerinde hasta dozu ve görüntü kalitesi optimizasyonu

    Patient dose and imaging quality optimisation in screen-film system, digitalization of film and digital radiography

    ELİF ÜNAL

    Yüksek Lisans

    Türkçe

    Türkçe

    2014

    Fizik ve Fizik MühendisliğiAnkara Üniversitesi

    Medikal Fizik Ana Bilim Dalı

    PROF. DR. MEHMET DOĞAN BOR

  3. Bilgisayarlı tomografik görüntüleme tekniklerinin karşılaştırılması

    Başlık çevirisi yok

    İ.HAKKI BOZKURT

    Yüksek Lisans

    Türkçe

    Türkçe

    1993

    Elektrik ve Elektronik MühendisliğiErciyes Üniversitesi

    Elektronik Ana Bilim Dalı

    YRD. DOÇ. DR. M. KEMAL KIYMIK

  4. Prediction of COVID 19 disease using chest X-ray images based on deep learning

    Derin öğrenmeye dayalı göğüs röntgen görüntüleri kullanarak COVID 19 hastalığının tahmini

    ISMAEL ABDULLAH MOHAMMED AL-RAWE

    Yüksek Lisans

    İngilizce

    İngilizce

    2024

    Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve KontrolGazi Üniversitesi

    Bilgisayar Mühendisliği Ana Bilim Dalı

    PROF. DR. ADEM TEKEREK

  5. Comparison of digital and conventional X-ray systems in terms of structure and image quality

    Dijital ve konvansiyonel X-ışın sistemlerinin yapısal ve görüntü kalitesi açısından karşılaştırılması

    NAZİME TOKGÖZ

    Yüksek Lisans

    İngilizce

    İngilizce

    2019

    Elektrik ve Elektronik MühendisliğiAnkara Yıldırım Beyazıt Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ ÖMER KARAL