Geri Dön

Monte Carlo simülasyonu ile radyasyondan koruyucu malzemelerde kullanılan bizmut, kurşun ve alternatif kompozit malzemelerin atenüasyon etkilerinin değerlendirilmesi

Monte Carlo evaluation of the attenuation effects of bismuth, lead and alternative composite materials used in radiation protection

  1. Tez No: 424609
  2. Yazar: GİZEM ŞİŞMAN
  3. Danışmanlar: YRD. DOÇ. DR. HAKAN EPİK, YRD. DOÇ. DR. AYŞEGÜL YURT
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Radyoloji ve Nükleer Tıp, Physics and Physics Engineering, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2015
  8. Dil: Türkçe
  9. Üniversite: Dokuz Eylül Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Medikal Fizik Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 77

Özet

Amaç: Tanısal incelemelerde bazen hedef organlar dışında radyasyona duyarlı organlar da tarama alanı içinde kalmakta ve gereksiz yere doz almaktadır. Radyasyon maruziyeti sonucu hasarı ve oluşabilecek kanser riskini azaltmak amacıyla hastalar üzerinde kullanılan Bizmut (Bi) koruyucular için yüksek maliyet ve kullanım pratikliğindeki yetersizlik gibi olumsuz görüşler bulunmaktadır. Radyasyon ile çalışanların korunmasında kullanılan Kurşun (Pb) koruyucuların ise; ağırlıklarından dolayı kullanım zorluğu oluşturmaları ve yüksek toksisite nedeniyle kullanımları tercih edilmemektedir. Çıkış noktası olarak bu eksikliklerin baz alındığı çalışmada yeni koruyucu malzemelerin geliştirilebilmesi için Monte Carlo (MC) Simülasyonu ile bazı elementlerin ve simülasyonda oluşturulan kompozitlerin atenüasyon etkilerinin değerlendirilmesi hedeflenmiştir. Gereç ve Yöntem: MC tabanlı GAMOS simülasyon programında diagnostik radyoloji enerji aralığı ile uyumlu olarak artan enerjilerde bazı metal ve lantanit grubu elementlerin enerjiye bağlı kütle atenüasyon katsayılarındaki değişikliklere ve kalınlığa bağlı doz azalımlarına bakılmıştır. NIST (National Institue of Standarts and Technology) veri tabanında sunulan kütle atenüasyon değerleriyle sonuçların verifikasyonu yapıldıktan sonra (hata< %3) karışımlarda kullanılacak elementlerin yüzde oranları belirlenerek 20 örnek oluşturulmuştur. Elementlerin seçiminde K tabaka bağlanma enerjisi, atom numarası, yoğunluk, toksisite özellikleri göz önünde bulundurulmuştur. Bulgular: Simüle edilen 20 örnek bizmut ve kurşunun azalım garfikleri ile karşılaştırılmış ve en iyi 10 tanesi seçilmiştir. Örneklerin büyük kısmında bizmuta göre 50-90keV ve kurşuna göre de 50-80 keV aralığında daha yüksek kütle atenüasyon değerleri elde edilmiştir. Sonuç: Oluşturulan çalışma uzayı ile örneklerin atenüasyon etkileri değerlendirilerek belli bir enerji aralığına bağlı olarak bizmut ve kurşuna alternatif olacak en iyi örnekler belirlenmiştir. Bunlardan en başarılıları örnek 3 (Evropiyum, Disporsiyum, Baryum, Bizmut), örnek 8 (İterbiyum, Erbiyum, Evropiyum, Bizmut) ve örnek 9 (İterbiyum, Erbiyum, Antimon ve Bizmut) olmuştur. Anahtar Sözcükler : Monte Carlo Hesaplamaları, Radyasyondan Korunma, x-ışını

Özet (Çeviri)

Objective: In some diagnostic examinations, area of interest not only includes target organs but also radiation sensitive organs which are unnecessarily irradiated. There are adverse opinions like high cost and lack of practicality in use regarding Bismuth (Bi) shielding materials which are used on patients to decrease radiation damage and probable risk of cancer as a result of exposure to radiaton. On the other hand, for Lead (Pb) shielding materials which are used for the protection of radiation workers, there are several disadvantages due to high weight and toxicity of the material making them not preferable. This study which has its base focused on the deficiencies defined above, aims to use Monte Carlo (MC) simulation software for the evaluation of the attenuation effects of some elements and composite materials created by the software in order to develop new shielding materials. Material and Method: MC based GAMOS simulation program has been used in compliance with the diagnostic energy range to examine the differences between energy dependent mass attenuation coefficients of some metals and lanthanides, as well as the amount of dose reduction due to shielding thickness. Following the verification of the obtained results with the mass attenuation values offered in the NIST (National Institute of Standards and Technology) database (error

Benzer Tezler

  1. Kavite yoğunluğunun soğurma oranlarına etkisinin Monte Carlo simülasyonu ile incelenmesi

    The investigation of the effect of cavity density on absorption rates using by Monte Carlo simulation

    ONUR BAYINDIRCI

    Yüksek Lisans

    Türkçe

    Türkçe

    2021

    EnerjiEge Üniversitesi

    Nükleer Bilimler Ana Bilim Dalı

    DOÇ. DR. BERKAY CAMGÖZ

  2. Malzeme yapısının radyasyondan korunmadaki etkisinin Monte Carlo simülasyon yöntemi ile incelenmesi

    Investigation of the effect of material structure on radiation protection by Monte Carlo simulation method

    TUĞBA MANİCİ

    Doktora

    Türkçe

    Türkçe

    2024

    Fizik ve Fizik Mühendisliğiİstanbul Üniversitesi

    Fizik Ana Bilim Dalı

    PROF. DR. BAYRAM DEMİR

    DR. ÖĞR. ÜYESİ YAŞAR KARABUL

  3. Polyester matrisli bor karbür takviyeli nötron radyasyonu zırhlama malzemesi geliştirilmesi ve karakterizasyonu

    Boron carbide reinforced polyester matrised neutron radiation shielding material development and characterization

    TUNCAY TUNA

    Yüksek Lisans

    Türkçe

    Türkçe

    2017

    Makine MühendisliğiYıldız Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. AYŞEGÜL AKDOĞAN EKER

  4. Bazı biyomalzemelerin radyasyon soğurma özelliklerinin araştırılması

    Investigation of the radiation absorption properties of some biomaterials

    AYCAN ŞENGÜL

    Doktora

    Türkçe

    Türkçe

    2022

    Fizik ve Fizik MühendisliğiSüleyman Demirel Üniversitesi

    Fizik Ana Bilim Dalı

    PROF. İSKENDER AKKURT

  5. Göğüs röntgenogramlarında hasta dozunun Monte Carlo Yöntemi ile belirlenmesi

    Monte Carlo estimation of patient dose in chest roentgenography

    NURAY ER

    Yüksek Lisans

    Türkçe

    Türkçe

    2003

    Fizik ve Fizik MühendisliğiHarran Üniversitesi

    Fizik Ana Bilim Dalı

    YRD. DOÇ. DR. AHMET BOZKURT