Frekans sıkıştırma özelliği olan işitme cihazlarının işitsel çözünürlük üzerindeki etkisinin akustik değişim kompleksi ile incelenmesi
The effect of frequency compression on auditory resolution using acoustic change complex
- Tez No: 431608
- Danışmanlar: PROF. DR. FERDA AKDAŞ
- Tez Türü: Doktora
- Konular: Kulak Burun ve Boğaz, Otorhinolaryngology (Ear-Nose-Throat)
- Anahtar Kelimeler: Frekans Düşürme, Lineer Olmayan Frekans Sıkıştırma, Akustik Değişim Kompleksi, Ölü Bölge, Frequency Lowering, Nonlinear Frequency Compression, Acoustic Change Complex, Dead Region
- Yıl: 2016
- Dil: Türkçe
- Üniversite: Marmara Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Kulak Burun Boğaz Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 89
Özet
Amaç: Frekans sıkıştırma özelliğinin aktif hale gelmesi ile yüksek frekans bilgisi içeren uyaranı, kortikal seviyede ayırt etmenin, Akustik Değişim Kompleksi (ADK) ile incelenmesi ve normal işiten bireylerin ADK cevapları ile karşılaştırılmasıdır. Ayrıca, frekans sıkıştırma özelliğinin ayarlama yöntemlerinin karşılaştırılması amaçlanmıştır. Gereç ve Yöntem: Bu çalışmaya 30 normal işiten ve 20 işitme kayıplı birey dahil edilmiştir. 500 ve 4000 Hz tonal uyaran içeren 1000 msn uzunluğunda bir uyaran ile ADK kaydı yapılmıştır. Frekans sıkıştırma özelliğini ayarlamak için belirlenmesi gereken başlangıç frekansı ve sıkıştırma oranı, cihaz yazılımındaki varsayılan ayarlara, optimal ayarlamaya ve ekstra sıkıştırma gereksinimine göre yapılmış ve her bir durum için ADK kaydedilmiştir. P1-N1-P2 dalga kompleksi ve ADK kompleksi dalga latanslarına göre değerlendirme yapılmıştır. Bulgular: Tüm bireylerde ADK elde edilmiştir. İşitme kayıplı bireylerin tüm dalga latans ortalamaları normal işitenlere göre daha uzun elde edilmiştir. Başlangıç frekansı açısından varsayılan ayarlar (BFv) ile optimal ayarlar arasında (BFo), optimal ayar ile ekstra sıkıştırma (BFe) arasında ve varsayılan ayarlar ve ekstra sıkıştırma ayarları arasında anlamlı farklılık bulunmuştur. Sıkıştırma oranları karşılaştırıldığında varsayılan (SOv), optimal (SOo) ve ekstra sıkıştırma (SOe) oranları arasında istatistiksel farklılık bulunmamıştır. Sonuç: Kortikal düzeyde yüksek frekans bilgisinin algılanması için başlangıç frekansı ve sıkıştırma oranı belirlenmesinde sadece varsayılan parametrelere bağlı kalınmamalıdır. Yetersiz sıkıştırma veya gerektiğinden fazla sıkıştırma yapmadan, optimal bant genişliği ayarlanmalıdır. Ayar doğrulamasında, gerçek kulak ölçümlerinin yanı sıra objektif bir yöntem olarak ADK uygulanabilir.
Özet (Çeviri)
Aim: The study is concern with the distinguishing of the stimuli containing high frequency information with the frequency compression feature at the cortical level using the Acoustic Change Complex (ACC) and the comparison of such with the ACC answers of individuals with normal hearing. Method: 30 individuals with normal hearing and 20 individuals with hearing loss have been included in this study. 1000 msec long stimulus containing 500 and 4000 Hz tonal stimuli is used for ACC recording. The start frequency (SF) and compression ratio (CR) parameters of the hearing aids were programmed according to the default settings (SFd, CRd) in the device software, the optimal setting (SFo, CRo) and the extra compression (SFe, CRe) requirements and ACC has been recorded for each condition. Evaluation has been performed according to P1-N1-P2 wave complex and ACC complex wave latencies. Results: In all individuals ACC has been observed. There was a significant difference between the wave latencies in normal hearing and hearing impaired groups. All wave latency averages of the individuals with hearing impairment were longer then the individuals with normal hearing. There were statistically significant differences between SFd-SFo, SFd-SFe and SFo-SFe parameters. But there was no difference between CRd, CRo and CRe in terms of compression ratios. Conclusion: In order to discriminate high frequency information at the cortical level we should not rely on default settings of the start frequency and compression ratio of the hearing aids. Optimal bandwidth must be adjusted without performing insufficient compression or over-compression. ACC can be used besides the real ear measurement for hearing aid fitting.
Benzer Tezler
- Sensörinörinal işitme kaybı olan çocuklarda işitme cihazlarının frekans sıkıştırma özelliğinin işitsel kortikal cevaplarla incelenmesi
Evaluation of responses cortical auditory evoked potential by frequency compression in children with sensorineural hearing loss
MUSTAFA ÇAĞRI DERİCİ
Tıpta Uzmanlık
Türkçe
2019
Kulak Burun ve BoğazSağlık Bilimleri ÜniversitesiKulak Burun Boğaz Hastalıkları Ana Bilim Dalı
DR. ÖĞR. ÜYESİ GÖKHAN KURAN
- İşitme kayıplı yetişkinlerde frekans düşürme teknolojisinin konuşmayı anlamaya ve P1-N1-P2 dalgalarına etkisi
Effect of frequency lowering technology on speech understanding and P1-N1-P2 waves in adults with hearing LOSS
ASLIHAN SAYAN BAYRAK
Yüksek Lisans
Türkçe
2023
Kulak Burun ve BoğazDokuz Eylül ÜniversitesiKulak Burun Boğaz Ana Bilim Dalı
PROF. DR. GÜNAY KIRKIM
- A block proccessing approach for doppler centroid estimation
Doppler merkezi kestirimi için blok işleme yaklaşımı
PELİN TUNÇAY
Yüksek Lisans
İngilizce
2013
Elektrik ve Elektronik Mühendisliğiİstanbul Teknik Üniversitesiİletişim Sistemleri Ana Bilim Dalı
DOÇ. DR. MESUT KARTAL
- Investigation of different properties of bamboo fibers reinforced rigid polyurethane foams
Bambu lifleri ile güçlendirilmiş sert poliüretan köpüklerin çeşitli özelliklerinin incelenmesi
DAMLA UYGUR
Yüksek Lisans
İngilizce
2024
Polimer Bilim ve Teknolojisiİstanbul Teknik ÜniversitesiPolimer Bilim ve Teknolojisi Ana Bilim Dalı
PROF. DR. İBRAHİM ERSİN SERHATLI
- Wavelet frames and redundant wavelet transforms for fault detection
Dalgacık çerçeveleri ve artıklı dalgacık dönüşümleri ile arıza tespiti
TAYFUN ŞENGÜLER
Doktora
İngilizce
2017
Elektrik ve Elektronik Mühendisliğiİstanbul Teknik ÜniversitesiElektrik Mühendisliği Ana Bilim Dalı
PROF. DR. ŞAHİN SERHAT ŞEKER