Silikon esaslı maksillofasiyal protez malzemelerinin alt yapı malzemelerine bağlanma özelliklerinin araştırılması

The investigation of the bonding properties of silicone based maxillofacial prosthetic materials to the framework materials

  1. Tez No: 431921
  2. Yazar: BEGÜM YERCİ KOSOR
  3. Danışmanlar: PROF. DR. ATİLLA İSMAİL KESERCİOĞLU
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2015
  8. Dil: Türkçe
  9. Üniversite: Ege Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 121

Özet

Çene-yüz bölgesinde doğumsal malformasyonlar, travma, kanser cerrahisi gibi sebeplerle meydana gelen defektlerin protetik rehabilitasyon süreci hem hekim hem de hastayı zorlayan pahalı ve uzun bir süreçtir. İmplant destekli protezlerde kullanılan bar-klipslerin veya magnetlerin sekonderlerini taşıyan ve yüz protezine dayanak sağlayan alt yapı materyalleri ile üst yapıyı oluşturan silikon elastomer arasındaki bağlantı başarısızlıkları klinik açıdan oldukça büyük bir problem oluşturmaktadır. Çene yüz protezleri alanında son senelerde fiber destekli kompozitler alt yapı materyali olarak kullanılmaya başlanmıştır. Bu in vitro çalışmada deneysel fiber destekli kompozit (F) alt yapı materyali ile ortoakril (O) ve ışıkla sertleşen kaide materyali (U) arasında ilave tip silikon elastomere bağlantı açısından fark olup olmadığı 180˚ soyulma ve makaslama testleriyle araştırılmıştır. 180˚ soyulma testi için (N=45, n=15/grup) 75×10×3 mm'lik alt yapılar hazırlandı. Aynı boyutta üst yapılarla muflalama işlemiyle primer (G611 platinum primer, Principality Medical, UK) aracılığıyla bağlantı sağlandı. Örnekler Xenotest Alpha test cihazında 200 saat yaşlandırmaya maruz bırakıldı.180˚ soyulma testi universal test cihazında (Autograph Model AG-IS 100 kN, Shimadzu, Kyoto, Japonya) 10 mm çene hızı ile gerçekleştirildi. Makaslama testi örnekleri (N=45, n=15/grup), otopolimerizan pembe akrilikten (Duracryl Self Cure, Duradent Erk Dental, Türkiye) silindirik ankastreler içine hazırlandı (25 mm boy×16 mm çap). Üzerlerine 8 mm çap, 3 mm boyundaki silikon elastomerler primer yardımıyla muflalama işleminde bağlandı. Örnekler Xenotest Alpha test cihazında 200 saat yaşlandırmaya maruz bırakıldı.Hazırlanan örnekler çalışmaya özel olarak hazırlanan aparata yerleştirilerek universal test cihazında 10 mm/dk çene hızı ile test edildi. Tüm örneklerdeki ayrılma tipi 10 büyütmeli büyüteç ile incelenerek adeziv, miks ve koheziv olarak kaydedildi. İstatistiksel analiz (Kolmogorov- Smirnov, Ki-kare, Anova, α=0,05) sonucu ortalama SG (makaslama bağlantı gücü) değerleri incelendiğinde alt yapılar arasındaki makaslama bağlantı gücü farkı O(0,6600±0,0515), U(0,5993±0,5516) ve F(0,6820±0,0553) grupları arasında anlamlı bulunmamıştır (p>0,05). Makaslama testi alt grupları arasındaki fark, ayrılma tipi bakımından istatistiksel olarak anlamlıdır (p0,05). O(0,3267±0,0952) grubu, U(0,8953±0,1897) ve F(0,8807±0,2259) gruplarından istatistiksel olarak anlamlı oranda düşük bulunmuştur (p0,05). O grubunda %100 adeziv ayrılma, U grubunda %100 adeziv ayrılma, F grubunda ise %80 adeziv, %20 miks ayrılma gözlemiştir. Tüm 180˚ soyulma testi alt gruplarında adeziv ayrılma %93,3, miks ayrılma %6,7 oranında görülmüş, koheziv ayrılmaya rastlanmamıştır. Yapılan SEM incelemelerinde, adeziv kopma gösteren örneklerde mikron düzeyinde silikon kalıntılarının olduğu gözlenmiştir. Genel olarak silikon kopma yüzeyleri düzensiz görülmüştür. Bulgular ışığında deneysel fiber destekli kompozit grubunun alt yapı materyallerine alternatif olabileceği gözlenmiştir ancak materyalin ileri tetkikine ve klinik araştırmaya ihtiyaç vardır.

Özet (Çeviri)

Rehabilitation process of the defects that are in the maxillofacial area caused by congenital malformations, trauma and cancer surgery is an expensive and long challenge both for the prosthodontist and the patient. The bonding failure that occurs between the maxillofacial silicone elastomer and the framework that supports the maxillofacial prosthesis, holds the bar-clips and the magnets that are used in the implant supported maxillofacial prosthesis causes important clinical problems. Recently, fiber reinforced composites are being used as frameworks. In this in vitro study, the bonding is compared with 180˚ peel test and shear test between experimental fiber reinforced composite (F), orthoacrylic (O) and light cure denture base material (U) frameworks to the additional type silicone elastomer. For the 180˚ peel test (N=45, n=15/group), 75×10×3 mm frameworks were produced. The bonding between the same diameters silicone elastomer and the frameworks was made by the flasking process by the aid of the primer (G611 platinum primer, Principality Medical, UK). The specimen were artificially aged in the Xenotest Alpha aging chamber for 200 hours. 180˚ peel test was carried out in the universal testing machine (Autograph Model AG-IS 100 kN, Shimadzu, Kyoto, Japan) with 10 mm/min crosshead speed. The shear test specimens (N=45, n=15/group) were prepared in cylindrical fixtures (25 mm length×16 mm diameter) made of autopolymerising acrylic (Duracryl Self Cure, Duradent Erk Dental, Turkey). The silicone elastomer (3 mm length, 8 mm diameter) was bonded with the aid of the primer in the flasking process. The specimen were artificially aged in the Xenotest Alpha aging chamber for 200 hours. The specimen were positioned in the apparatus made for this study and tested with the cross head speed of 10mm/min the universal testing machine. All specimen were inspected with a magnifier (10×) and the failure were grouped as adhesive, mix and cohesive. The mean SG (shear bonding strength) values of the frameworks were evaluated statistically (Kolmogorov- Smirnov, Chi-square , Anova, α=0,05), O(0,6600±0,0515), U(0,5993±0,5516) and F(0,6820±0,0553) were not found significantly different (p>0,05). The shear test subgroups' bonding failure type were significantly different (p0,05). The O(0,3267±0,0952) group was found statistically lower than U(0,8953±0,1897) and F(0,8807±0,2259) groups (p0,05). The O group showed 100 % adhesive failure, the U group showed 100% adhesive failure and the F group showed 80% adhesive and 20% mix failure. In all the 180˚ peel test subgroups, 93,3% adhesive failure and 6,7% mix failure was observed and cohesive failure was not observed. In SEM analysis, the specimen which showed adhesive failure showed residuel silicone. Generally, the silicone failure surfaces were seen irregular. It is observed that the experimental fiber reinforced composite could be an alternative to the other frameworks but further investigation and clinical studies should be carried out on this new material.

Benzer Tezler

  1. Maksillofasial silikonların 3 farklı rezin esaslı materyale bağlanma dayanımının belirlenmesi

    Determination of bond strength of 3 different resin based materials of maxillofacial silicones

    SENEM ÜNVER

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2017

    Diş HekimliğiGazi Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. SEÇİL KARAKOCA NEMLİ

  2. Silikon esaslı ölçü materyallerinin metal ölçü kaşıklarına tutuculuğunu arttıran faktörlerin araştırılması

    The Mechanical retention of silicone impressio materials on the stoch trays

    YEŞİM ÇEVİK

    Doktora

    Türkçe

    Türkçe

    1999

    Diş Hekimliğiİstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. YASEMİN ARAS

  3. Silikon esaslı makroinimer varlığında yeni organojellerin sentezi, karakterizasyonu ve absorbent olarak kullanımı

    Synthesis and characterization of novel organogels in the presence of silicone based macroinimer and usage as abrsobent

    NIGAR MAMMADLI

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    KimyaKocaeli Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. UFUK YILDIZ

  4. Silikon esaslı dış cephe boyalarının deneysel olarak incelenmesi

    An experimental investigation on silicon based exterior frontage paints

    ZEHRA FURTANA

    Yüksek Lisans

    Türkçe

    Türkçe

    2006

    KimyaGazi Üniversitesi

    Yapı Eğitimi Ana Bilim Dalı

    DOÇ.DR. YILMAZ ARUNTAŞ

  5. Silikon esaslı yumuşatıcıların pamuklu kumaşların konfor özelliklerine etkisinin incelenmesi

    The investigation of the effect of silicone essential softeners on comfort properties of cotton fabrics

    GÖZDE ÖZLEM KINOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    2014

    Tekstil ve Tekstil MühendisliğiKahramanmaraş Sütçü İmam Üniversitesi

    Tekstil Mühendisliği Ana Bilim Dalı

    DOÇ. DR. ONUR BALCI

    DOÇ. DR. CEM GÜNEŞOĞLU