A non-fiber optical set up for the measurement of patient response time in functional magnetic resonance imaging

Fonksiyonel manyetik rezonans görüntülemede hasta yanıt sürelerinin fiber optiksiz ölçümü için bir sistem

  1. Tez No: 438655
  2. Yazar: MEHMET ÜNSAL
  3. Danışmanlar: YRD. DOÇ. DR. ALİ ÜMİT KESKİN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Elektrik ve Elektronik Mühendisliği, Radyoloji ve Nükleer Tıp, Tıbbi Biyoloji, Electrical and Electronics Engineering, Radiology and Nuclear Medicine, Medical Biology
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2008
  8. Dil: İngilizce
  9. Üniversite: Yeditepe Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Elektrik-Elektronik Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 70

Özet

Fonksiyonel görüntüleme (fMRI) vücutsal işlevleri veya düşünsel aktiviteyi beyindeki belirgin bölgelerle ilintiliyen bir görüntüleme tekniğidir. Bu görüntüleme motor, duyumsal ve/veya algılama işlemlerinde yer alan yerel nöron aktivitesinin çalışılmasında çok güçlü bir araç olmuştur. Günümüz nöroanotomi bilgisi invaziv anatomik ve patolojik araştırmalara dayanır. Öte yandan fMRI ise nöronal aktiviteyi tanımlayan invaziv olmayan bir yöntemdir. Böylelikle söz konusu teknik önemli klinik uygulamalara sahip olabilir.Belirli bir işleve veya duyumsal sürece bağlı beyin faaliyetlerini görüntülemede fMRI yönteminin temel yararları şunlardır: 1- İşaret radyoaktif izotopların enjeksiyonun gerektirmez. 2-Toplam tarama süresi çok kısa olabilmektedir. (paradigmaya bağlı olarak 1.5-2 dakika mertebesindedir.)Rutin uygulamadaki fMRI tetkiklerinin çoğunda parmak dokundurma gibi basit hasta yanıt yöntemleri kullanırken, daha gelişmiş fMRI tekniklerinde (örneğin performansla beyin aktivasyonu arasındaki ilişki çalışıldığında) bazı ilave düzenekler (örneğin hasta yanıt anahtarı, arabirim ve kayıt düzenleri) gerekir. Hasta yanıt anahtarı (PRS) hasta tepki sürelerinin ölçümünü sağlar. Bir fiberoptik anahtarlı yanıt sistemi temel olarak fMRI anahtar yanıt birimi ve MR projeksiyon sisteminden oluşur. Fiberoptik yanıt düzeni (FO-PRS) sistemi hazır denek yanıt toplama sistemidir ve deneklerden gelen yanıtları alıp işaretleri tetkik etmeye yaramaktadır.FO-PRS'ler deneklerin (hastaların) bileklerine takılır ve tarama sırasında ayarlanabilirler. Bu birimler tamamen fiberoptiktirler ve mevcut bir dalga klavuzu aracılıgıyla kontrol odasında bulunan bir fiberoptik arabirim düzenine bağlanırlar. Sistem diğer veri toplama aygıtlarıyla ve yazılımla etkileşimde kullanılacak TTL çıkış işaretlerini üretir. Arabirim, kullanıcının deneylerini MRI cihazıyla eş güdümlü olarak kullanılmasına sağlayacak donanıma sahiptir.Halen ticari olarak mevcut olan cihazlar veri toplama bilgisayarına USB bağlantısı ile seri terminal çıkışlarını sağlarlar, ancak hasta odasıyla kumanda odası arasında ilave bir dalga klavuzu gereklidir. Diğer yandan mevcut dalga klavuz kanalı, daha önceden montajı yapılan MRI sistemine ait kabloların sıkışıklığı nedeni ile yada gerekli bağlantının sağlanmasındaki kablo uzunluklarının yetersizliğinden dolayı kullanılamayabilir. Bu zorluklar optik tekniklerin pratik kullanımını engeller yada (ekstra kablo montajı, izolasyonu ve RF ekranlaması için) pahalı malzeme ve iş gücü kullanımını gerektirir.Optik yöntemler (özellikle fMRI tetkikinde) gradyan ve RF bobinlerinden kaynaklanan yüksek güçlü elektromanyetik işaretlerin etkisini yok etmek amacıyla tercih edilmektedir. Bunlara ilaveten (3 Tesla gibi) yüksek bir sabit manyetik alan hasta odasında mevcut bulunmaktadır.Bu çalışmada amaç, nispeten pahalı fiberoptik düzen ve fiberoptik arabirimin işlevinin benzerinin (uyarı ölçme düzeni ve MRI'ya etkisi olmayan) basit bir elektronik düzenle gerçekleştirilebilecegi göstermektedir. Bu ölçme ve arabirim düzenin maliyeti mevcut ekipmana göre çok daha düşüktür. Çalışmada kullanılan teknik detaylı olarak açıklanarak, bir 3 Tesla MRI cihazında uygulaması ve performans sonuçları verilmiştir.

Özet (Çeviri)

Functional imaging is imaging which relates body function or mental activity to specific locations in the brain. It has become a powerful instrument to study local neuronal activity involved in motor, sensory and/or cognitive tasks. Extension of this technique to the spinal cord shows great promise for research and clinical applications. The current knowledge of neuroanatomy is mainly based upon invasive anatomical and pathological research. fMRI is a promising technique to demonstrate neuronal activity as it is performed in a noninvasive way. Thus the technique may have important clinical uses.The main advantages to fMRI as a technique to image brain activity related to a specific task or sensory process include 1) the signal does not require injections of radioactive isotopes, 2) the total scan time required can be very short, i.e., on the order of 1.5 to 2.0 min per run (depending on the paradigm).Although most fMRI examinations in routine practice employ simple patient response methods such as finger tapping, in modified fMRI examinations where the correspondence between performance and brain activation is studied, some additional instrumentation, like ?patient response switch (PRS), interface and recorder? is required. PRS based instrumentation makes patient reaction times to be measured. A Fiber Optic Button Response System (FO-PRS) mainly consists of fMRI Button Response unit (e.g., Psychology Software Tools, Pittsburgh, PA) with MR Projection System. The Fiber Optic Button Response System is an fMRI ready subject response collection system which has been engineered to gather subject responses and verify signals.The Fiber Optic Button Response Units attach to the subject's wrists and can be adjusted during scanning. These units are completely fiber optic and connect to a fiber Optic Interface Console located in the control room through an available wave guide. The interface console provides real-time feedback of subject responses via LED indicators and includes a set of switches which can be used to make responses for the subject as needed. The system provides TTL output signals that can be used to interface with other data collection devices and software. The interface console comes with a RF Pulse that the computer interprets as another button press, allowing the user to synchronize their experiments with the MR scanner.Such a commercially available standard unit comes with some (14-meter long) cables, and provides serial port and USB connection to the data collection computer. However, an additional waveguide is required between the patient room and the operating room. On the other hand, existing wave-guide channel may not be employed, since it may already be crowded with the earlier installed cables or the length of the supplied cables can be too short to provide the required connection. These difficulties prevent the practical use of such a technique, or require hiring of expensive skilled labor for extra cable installation, isolation and RF shielding.At present optical means of fMRI instrumentation is preferred, because, there exist intensive electromagnetic signals generated by gradient and RF coils (during an fMRI examination, in particular). In addition, there is a strong constant magnetic field (as high as 3 Tesla) within the patient room, and optical signal processing may seem to be reasonable to avoid distortions in such an environment.In this study, we show that relatively expensive fiber optical unit and fiber optical interface can be replaced by simple electronics without any disturbance to stimulus measuring unit as well as to the MRI. The cost of the measuring and interface unit whose performance has been reported in this work is very low as compared to commercially available equipment.

Benzer Tezler

  1. Set-up of a 2-color pyrometer and design of a radiative calibration cell

    2 renkli pirometre kurulumu ve ışınımsal kalibrasyon hücresi tasarımı

    KAAN ERDEM

    Yüksek Lisans

    İngilizce

    İngilizce

    2012

    Makine Mühendisliğiİstanbul Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. ABDURRAHMAN KILIÇ

  2. İç ortamdaki inorganik ve organik kirleticilerin yeni teknolojiler ile giderilmesi

    Removal of inorganic and organic pollutants in the indoor air by new technologies

    BİLGE BETÜL ÖZÇELİK

    Yüksek Lisans

    Türkçe

    Türkçe

    2020

    Kimya Mühendisliğiİstanbul Teknik Üniversitesi

    Kimya Mühendisliği Ana Bilim Dalı

    PROF. DR. MELEK MÜMİNE EROL TAYGUN

  3. Yüksek gerilim aparatlarında elektro - optik metodla akım ve gerilim ölçüleri

    Current and voltage measurement for high voltage equipments by electro - optic methods

    HÜSEYİN YILMAZ

    Yüksek Lisans

    Türkçe

    Türkçe

    2002

    Elektrik ve Elektronik MühendisliğiGazi Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    PROF. DR. M. CENGİZ TAPLAMACIOĞLU

  4. İn-vivo doku oksijen saturasyonunun ölçülmesi için spektroskopik bir yöntemin geliştirilmesi ve postoperatif flep olgularında doku canlılığını belirlemede kullanılması

    Development of spectroscopic method for measuring in-vivo tissue oxygen saturation and using it in postoperative flap surgery for assessment of tissue perfusion

    ASLINUR SIRCAN KÜÇÜKSAYAN

    Doktora

    Türkçe

    Türkçe

    2017

    BiyofizikAkdeniz Üniversitesi

    Biyofizik Ana Bilim Dalı

    PROF. DR. MURAT CANPOLAT

  5. Topology and bandwidth adaptation in optical WDM backbone networks with dynamic traffic

    Değişken veri trafikli optik WDM omurga ağlarında topoloji ve bant genişliği uyarlama

    AYŞEGÜL GENÇATA

    Doktora

    İngilizce

    İngilizce

    2003

    Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve Kontrolİstanbul Teknik Üniversitesi

    Kontrol ve Bilgisayar Mühendisliği Ana Bilim Dalı

    PROF. DR. MEHMET BÜLENT ÖRENCİK