Vibrasyon ve soğuk uygulamanın damar yolu açma işlemi sırasında ağrı ve anksiyete üzerine etkisi
Effects of vibration and cold application on pain and anxiety during intravenous catheterization
- Tez No: 453799
- Danışmanlar: YRD. DOÇ. DR. KIVAN ÇEVİK
- Tez Türü: Yüksek Lisans
- Konular: Hemşirelik, Nursing
- Anahtar Kelimeler: İntravenöz kateterizasyon, vibrasyon, soğuk uygulama, ağrı, anksiyete, Kateterizasyon, Kateterler-kalıcı, Kriyoterapi, Soğuk, Soğuk uygulaması, Intravenous catheterization, vibration, cold application, pain, anxiety, Catheterization, Catheters-indwelling, Cryotherapy, Cold
- Yıl: 2016
- Dil: Türkçe
- Üniversite: Celal Bayar Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Hemşirelik Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç: Bu araştırma, intravenöz kateterizasyon sırasında hastalara uygulanan vibrasyon ve soğuk jel paket uygulamasının (Buzzy aygıtı) ağrı ve anksiyete düzeyi üzerine etkisini belirlemek amacıyla yapıldı. Gereç ve Yöntem: Araştırma, randomize kontrollü, ön test-son test deneysel bir çalışma olarak planlandı. Veri toplama aracı olarak,“Hasta Tanıtım Formu”,“İntravenöz Kateterizasyon İşlemine İlişkin Görüş Formu”,“Durumluk-Sürekli Anksiyete Ölçeği”ve“Görsel Kıyaslama Ölçeği”kullanıldı. Deney grubundaki hastalara intravenöz kateterizasyon işlemine başlamadan 60 sn. önce Buzzy aygıtı uygulanırken, kontrol grubundaki hastalara standart prosedüre uygun intravenöz kateterizasyon işlemi uygulandı. Bulgular: Deney grubundaki hastaların ağrı puan ortalamasının 1,04±0,96, memnuniyet puan ortalamasının 95,30±3,89; kontrol grubundaki hastaların ağrı puan ortalamasının 5,32±1,64, memnuniyet puan ortalamasının 82,12±7,48 olduğu ve gruplar arasındaki farkın anlamlı olduğu saptandı (p<0,001). Deney grubundaki hastaların işlem öncesinde durumluk anksiyete puan ortalaması 38,80±4,23, sürekli anksiyete puan ortalaması 46,28±6,19; kontrol grubundaki hastaların işlem öncesinde durumluk anksiyete puan ortalaması 39,76±3,90, sürekli anksiyete puan ortalaması 45,98±6,50 olarak belirlendi. Deney grubundaki hastaların işlem sonrasında durumluk anksiyete puan ortalaması 40,82±3,61, sürekli anksiyete puan ortalaması 46,48±6,44; kontrol grubundaki hastaların işlem sonrasında durumluk anksiyete puan ortalaması 40,84±3,80, sürekli anksiyete puan ortalaması 45,98±6,46 olarak bulundu. Deney ve kontrol grubundaki hastaların intravenöz kateterizasyon öncesindeki ve sonrasındaki durumluk ve sürekli anksiyete puan ortalamaları arasında istatistiksel olarak anlamlı bir fark olmadığı saptandı (p>0,05). İşlem öncesi ve sonrası nabız hızları karşılaştırıldığında; deney grubunda anlamlı fark saptanırken (p<0,05); kontrol grubundaki farkın anlamlı olmadığı saptandı (p>0,05). Sonuçlar: Buzzy aygıtının intravenöz kateterizasyona bağlı ağrıyı ve nabız hızını azalttığı, durumluk anksiyete düzeyini ve memnuniyet düzeyini arttırdığı, sürekli anksiyete düzeyini etkilemediği saptandı.
Özet (Çeviri)
Aim: This study was designed to determine effects of vibration and cold gel pack application (Buzzy device) to patients on pain and anxiety levels during intravenous catheterization. Method: The study was planned as a randomized controlled, pre-test-post-test experimental study.“Patient Identification Form”,“Opinion of Form for Intravascular Catheterization”,“State-Trait Anxiety Inventory”and“Visual Analog Scale”were used as data collection tool. Catheterization was performed 60 seconds before starting intravenous catheterization procedure by applying Buzzy device to patients in the experimental group. According to standard procedure, catheterization was performed to patients in the control group. Results: It was found that the mean pain scores of the patients in the experimental group 1,04±0,96, the mean satisfaction scores 95,30±3,89; the mean pain scores of the patients in the control group 5,32±1,64, the mean satisfaction scores 82,12±7,48 and the difference between the groups was significant (p<0,001). Before catheterization, it was found that the mean state anxiety scores of patients in the experimental group 38,80±4,23, the mean trait anxiety scores 46,28±6,19; the mean state anxiety scores of the patients in the control group 39,76±3,90, the mean trait anxiety scores 45,98±6,50. After catheterization, it was found that the mean state anxiety scores of patients in the experimental group 40,82±3,61, the mean trait anxiety scores 46,48±6,44; the mean state anxiety scores of the patients in the control group 40,84±3,80, the mean trait anxiety scores 45,98±6,46. Before and after intravenous catheterization in the each group, it was found that there was not significant between the mean state anxiety scores of patients and the mean trait anxiety scores of patients (p>0,05). When pulse rates are compared before and after the procedure; there was a significant difference in the experimental group (p<0,05); the difference in the control group was not significant (p> 0,05). Conclusions: Buzzy device was found to reduce pain and pulse rate that depend on intravenous catheterization, to increase state anxiety level and satisfaction level, to can not influence trait anxiety level.
Benzer Tezler
- Koroner arter bypass greft cerrahisi sonrası göğüs tüpü çıkarılması ile ilişkili ağrı ve anksiyeteye vibrasyon ve soğuk uygulamanın etkisi
Effect of vibration and cold application on chest tube removal pain and anxiety after coronary artery bypass graft surgery
ÖYKÜ KARA
Doktora
Türkçe
2025
Hemşirelikİstanbul Üniversitesi-CerrahpaşaCerrahi Hastalıklar Hemşireliği Ana Bilim Dalı
DOÇ. DR. NURAY AKYÜZ
- Sağlıklı bireylerde diz eklemine uygulanan farklı duyu uyarılarının denge, eklem pozisyon hissi ve hafif dokunma duyusu üzerine olan erken etkileri
Early effects of different sensory stimuli on balance, joint position sense and light touch sensation applied to the knee joint in healthy individuals
İLKEM GÜZEL
Yüksek Lisans
Türkçe
2020
Fizyoterapi ve RehabilitasyonHacettepe ÜniversitesiKas İskelet Fizyoterapisi ve Rehablitasyon Ana Bilim Dalı
PROF. DR. FİLİZ CAN
- Lomber disk hernisi tanısı konmuş hastalarda kantitatif duysal test ve manyetik rezonans görüntüleme ilişkisi
Relationship between magnetic resonance imaging and quantitative sensory testing at the patients with lumbar disc herniation
SERPİL CANAN
Tıpta Uzmanlık
Türkçe
2014
Anestezi ve ReanimasyonCelal Bayar ÜniversitesiAnesteziyoloji ve Reanimasyon Ana Bilim Dalı
PROF. DR. EMİN ALP YENTÜR
- 6XXX alüminyum alaşımında vakum destekli katılaşmanın gözenekliliğe etkisinin incelenmesi
Investigation of the porosity effect of vacuum assisted solidification in 6XXX aluminum alloy
MUHAMMED TAHA ARSLAN
Yüksek Lisans
Türkçe
2024
Metalurji MühendisliğiSakarya Uygulamalı Bilimler ÜniversitesiMetalurji ve Malzeme Mühendisliği Ana Bilim Dalı
DR. ÖĞR. ÜYESİ SELÇUK ŞİRİN
DR. LEVENT TURHAN
- Risk analysis and outlier detection in cold chain 4.0 logistics: an empirical study
Soğuk zincir 4.0 lojistiğinde risk analizi ve aykırı değer tespiti: ampirik bir çalışma
SEVDE CEREN YILDIZ ÖZENÇ
Doktora
İngilizce
2025
Endüstri ve Endüstri MühendisliğiMarmara ÜniversitesiEndüstri Mühendisliği Ana Bilim Dalı
PROF. DR. SENİYE ÜMİT FIRAT
DR. ÖĞR. ÜYESİ MERVE ER