Kardiyovasküler cerrahi yoğun bakımda yatan hastalarda vücut sıcaklığının ölçümünde infrared timpanik membran ile temassız infrared temporal arter termometrenin karşılaştırılması
Comparison of infrared tympanic membrane and contactless temporal artery thermometer in determining the body temperature of the patients who are treated in cardio-vasculer intensive care unit
- Tez No: 471555
- Danışmanlar: YRD. DOÇ. DR. SENNUR KULA ŞAHİN
- Tez Türü: Yüksek Lisans
- Konular: Hemşirelik, Nursing
- Anahtar Kelimeler: İnfrared timpanik membran termometre, temassız infrared temporal arter termometre, vücut sıcaklığı, yoğun bakım, kardiyovasküler cerrahi, infrared tympanic membrane, contactless temporal artery thermometer, body temperature, intensive care, cardiovascular surgery
- Yıl: 2017
- Dil: Türkçe
- Üniversite: İstanbul Medipol Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Hemşirelik Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 84
Özet
Vücut sıcaklığı, güvenli ve etkili bir bakım sağlamak için izlenmesi gereken yaşamsal bulgulardan biridir. Karmaşık, riskli ve majör cerrahi girişimi içeren kardiyovasküler cerrahi sonrası yoğun bakımda yatan hastalarda ise vücut sıcaklığının ölçümü çok önemlidir. Bu çalışma yoğun bakımda yatan hastaların vücut sıcaklıklarının belirlenmesinde kullanılan infared timpanik membran termometre (İTT) ve temassız infrared temporal arter termometrelerin (TİTAT) güvenirliklerini belirlemek amacıyla metodolojik, tanımlayıcı ve kesitsel olarak gerçekleştirildi. Çalışma İstanbul'daki bir kamu hastanesinin kardiyovasküler cerrahi yoğun bakım ünitesinde Nisan -Temmuz 2015 tarihleri arasında araştırma kriterlerine uyan ve araştırmaya katılmayı kabul eden toplam 60 hasta örneklemi oluşturdu. Hastaların tanıtıcı özellikleri ve vücut sıcaklıklarının takip edildiği veri toplama formu kullanıldı. Vücut sıcaklığı aynı hasta üzerinde iki termometre ile eşzamanlı ölçülerek kaydedildi. Veriler SPPS for Windows 17.0 program ve MedCalc 9.6.2.0 programı ile değerlendirildi. Çalışmada hastaların %50 (n=30)'sinin 50-65 yaş aralığında ve erkek olduğu, % 40 (n=24)'ının hafif şişman, % 57.6 (n=34)'sının 5 saat ve üzeri cerrahi girişim geçirdiği, yaş ortalamasının 54,2±13,5 (30-86) olduğu belirlendi. İTTile yapılan ölçüm değerlerinin (36,42 ± 0,72), TİTAT'den (36,02 ± 0,79)daha yüksek olduğu bulundu. Bland ve Altman eğrisine göre tekrarlanabilir katsayısı, uyum katsayıları, korelasyon ve saçılım grafikleri değerlendirildiğinde iki termometrenin birbiriyle uyumlu olduğu belirlendi. Kardiyovasküler cerrahi yoğun bakım ünitesindeki hastaların vücut sıcaklığının ölçümünde infared timpanik membran termometre ve temassız infrared temporal arter termometreleri birbirinin alternatifi olabileceği sonucuna varıldı. Sağlık çalışanlarının bu iki termometrenin kullanılmasının getirdiği avantaj ve dezavantajları göz önünde bulundurarak tercih edebilirler.
Özet (Çeviri)
Body temperature is a very valuable vital sign for a safe and an effective patient observation. Measurement of body temperature is very important after cardiovascular surgery, because cardiovascular procedures are very risky and complicated. In this methodological, descriptive, and cross-sectional study, we evaluated the safety of infrared tympanic membrane thermometer (İTT), and contactless infrared temporal artery thermometer(TİTAT), in cardiovascular intensive care patients. This study was performed with 60 patients who were eligible for the inclusion criteria, in a state hospital in Istanbul, between April 2015 – July 2015. Data collection forms were used for demographic data and body temperature measurements. Body temperature of the patients were measured with each thermometer at the same time. Results were evaluated with SPPS for Windows 17.0 and MedCalc 9.6.2.0 program. Fifty percent (n:30) of the patients were male and between 50-65 years, 40% (n: 23) of the patients were overweight, 57.6 % (n:34) had surgical procedure over 5 hours, and mean value of the age of the patients was 54.2 ± 13.5 (30-86). Body temperature measurements were slightly higher with İTT (36.42 ± 0.72), when compared to TİTAT(36.02 ± 0.79). According to Bland and Altman curve, repeatability, chi-square test, correlation and scatter charts were analyzed, and we observed similar results for each thermometer. As a result in cardiovascular intensive care unit, both type of thermometers can be used for measuring the body temperature. Health workers can prefer one of the thermometers considering the advantages and disadvantages of the each devise.
Benzer Tezler
- Kronik kalp yetmezliği olan hastalarda uzun süreli nutrisyonel destek uygulamalarının biyokimyasal parametreler, morbidite ve mortalite üzerine etkilerinin araştırılması
Investigation of the effects of long-term nutritional supplementation on biochemical parameters, morbidity and mortality in patients with chronic heart failure
BUKET ÖZYAPRAK
Tıpta Uzmanlık
Türkçe
2011
Anestezi ve ReanimasyonSağlık BakanlığıAnesteziyoloji ve Reanimasyon Ana Bilim Dalı
DR. AYŞE BAYSAL
- Kalp cerrahisi sonrası 'sepsiste sağkalım kampanyası' tedavi önerilerinin mortalite üzerine etkisi
After heart surgery 'survival in sepsis campaign' effect on mortality of treatment recommendations
EMİNE YURT
Tıpta Uzmanlık
Türkçe
2010
Anestezi ve ReanimasyonSağlık BakanlığıAnesteziyoloji ve Reanimasyon Ana Bilim Dalı
PROF. DR. ZEYNEP ZUHAL AYKAÇ
- Çocuk yoğun bakım ünitemizde izlenen hastalarda mortaliteyi etkileyen faktörlerin incelenmesi
Analysis of the factors affecting mortality in patients followed in our pediatric intensive care unit
MERVE MISIRLIOĞLU
Tıpta Uzmanlık
Türkçe
2016
Çocuk Sağlığı ve HastalıklarıAbant İzzet Baysal ÜniversitesiÇocuk Sağlığı ve Hastalıkları Ana Bilim Dalı
PROF. DR. NİMET KABAKUŞ
YRD. DOÇ. DR. MERVAN BEKDAŞ
- Yoğun bakımda sedasyon uygulanmasında midazolam ile midazolam ve magnezyum kombinasyonunun etkinliklerinin karşılaştırılması; bispektral indeks monitörizasyonu ile klinik sedasyonskorları arasındaki korelasyonundeğerlendirilmesi
Comparison of the activities of midazolam and midazolam and magnesium combinations in intensive care unit sedation implementation; evaluation of correlation bispectral index monitorization between clinical sedationscores
DİLEK ALTUN
Tıpta Uzmanlık
Türkçe
2010
Anestezi ve ReanimasyonSağlık BakanlığıAnesteziyoloji ve Reanimasyon Ana Bilim Dalı
DOÇ. DR. ZAFER ÇUKUROVA
- Non-invaziv mekanik ventilasyon uygulanan hastaların yaşadıkları sorunların ve bakım gereksinimlerinin değerlendirilmesi
Consideration of non-invasive mechanically ventilated patients' problems and nurturing needs
ÖZGE DURMUŞ
Yüksek Lisans
Türkçe
2014
Hemşirelikİstanbul Bilim ÜniversitesiHemşirelik Ana Bilim Dalı
YRD. DOÇ. DR. MAHMURE AYGÜN