Dağıtım sistemlerinde acil talep cevabı ve güç kayıplarının minimizasyonu

Emergency demand response and minimization of losses in distribution systems

  1. Tez No: 496381
  2. Yazar: FEYYAZ FATİH AYDIN
  3. Danışmanlar: DOÇ. DR. VEYSEL MURAT İSTEMİHAN GENÇ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Elektrik ve Elektronik Mühendisliği, Electrical and Electronics Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2017
  8. Dil: Türkçe
  9. Üniversite: İstanbul Teknik Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Elektrik Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Elektrik Mühendisliği Bilim Dalı
  13. Sayfa Sayısı: 103

Özet

Teknolojinin gelişmesiyle, dünya daha çok endüstriyelleşmiştir. Bu durum enerji talebini artırmıştır. Güç sistemlerindeki puant talep; nüfus artışı, yeni teknolojiler, çevresel kaygılar ve kullanıcı tercihi nedeniyle son yıllarda önemli oranda artış göstermiştir. Bunun yanı sıra elektrik enerjisine talepte, gün içerisinde de ciddi dalgalanmalar yaşamaktadır. Puant talebi karşılamak için elektrik şirketleri ya üretimlerini artırmakta ya da dinamik fiyatlama yapısına sahip toptan bir pazardan elektrik satın almaktadır. Böyle bir işletim, düşük bir yük faktörüne (ortalama yükün puant yüke oranı) yol açmaktadır. Bu açıdan; talebe göre üretimin yönetilmesi yerine özellikle talep gücünün, puant talebi azaltacak şekilde yönetilmesi, yani kontrol aksiyomlarının üretim tarafından tüketici tarafına kaydırılması son yıllarda oldukça dikkat çekici bir araştırma ve uygulama alanıdır. Bu tezde, dağıtım sistemlerinde meydana gelebilecek arızalarda, sistemin çalışmasını engelleyecek bozucu etkileri ortadan kaldırmak için gerekli yöntemler üzerine çalışma yapılmıştır. Bu çalışmada tüketicilerin dahil olduğu teşvik tabanlı talep cevabı programı kullanılmıştır. Meydana gelebilecek arızalar, tek amaçlı optimizasyon problemi olarak ele alınmıştır ve belirli kısıtlar altında önerilen algoritma vasıtasıyla bu problem çözülmüştür. Uygulanan optimizasyon metodunda, ana amaç baralardaki gerilimdeki gerilim seviyesinin normal çalışma koşullar altında uygun olmasını sağlamaktır. Ayrıca güç sistemindeki güç kayıplarının minimize edilmesi de bu tez çalışmasının diğer bir amacıdır. Bu bağlamda sezgisel optimizasyon yöntemlerinden biri olan Benzetilmiş Tavlama Algoritması kullanılmıştır. Bu algoritma MATLAB ortamında geliştirilmiştir. Bara gerilimi profilleri eşitsizlik kısıtı olarak değerlendirilirken karar değişkenleri olarak transformatör ayar kademesi, dağıtık üretim sistemlerinin güç faktörü ve yük atılacak baraların yük eğrisi karakteristikleri dikkate alınmıştır. Test sistemi olarak 23 bara'lı dengeli dağıtım sistemi kullanılmıştır. Bu test sistemini modellemede OpenDSS simulasyon programından yararlanmıştır. Bu programda, kullanılan test sistemi verileri, sabit nokta iterasyon yöntemine dayalı günlük yük akışı yapılacak şekilde düzenlenmiştir. Baralardaki yükler sabit güçlü olacak şekilde modellenmiştir ve reaktif ve aktif güç kısıtlamaları burada belirlenmiştir. Önerilen yöntemin performansını değerlendirmek için, bir çok çalışma, olası acil durum koşullarına göre sistemde düzeltme yapabilmek için yapılmıştır.İlgili test sistemine 3 adet düzeltme işlemi uygulanmıştır. Birinci düzeltme işlemi, transformatör ayar kademesinin ayarlanmasıyla sağlanmıştır. Mevcut test sisteminde, Transformatör başlangıçta devre dışı bırakılarak yük akışı yapılmıştır. Sistemde herhangi bir arızanın olmadığı göz önünde bulundurularak aktif güç kaybı, reaktif güç kaybı,1 faz gerilim profili ve amaç fonksiyonlarının maliyet değerleri belirlenmiştir. Test Sisteminde çalışan 4 adet DÜ'den biri saat 16:00 - 21:00 arasında devre dışı kalmıştır. Ayrıca saat 12:00 – 18:00 arasında Bara-23'te yük artışı gözlenmiştir. Arızalı sistemde gerilim profilini düzenlemek ve kayıpları azaltmak için sisteme sadece Transformatör ayar kademesi eklenmiştir. Transformatör kademesi -10 ile +10 arasında optimal olarak belirlenip , gerilim seviyesi düzenlenmiştir. İkinci işlem olarak reaktif güç planlanması yöntemi uygulanmıştır. Mevcut sisteme ek sabit bir transformatör kademe değiştirici eklenerek sistem modellenmesi yapılmıştır. Test Sisteminde çalışan 4 adet DÜ'den biri saat 12:00 - 15:00 arasında diğeri ise saat 21:00 – 24:00 arasında devre dışı kalmıştır. Ayrıca gün boyunca Bara-7 ve Bara 16 'da önemli bir yük artışı olmuştur. Bu arıza durumuna göre sistemdeki gerilim seviyesini düzeltmek ve kayıpları azaltabilmek için çalışan 2 adet DÜ'nin aktif gücü sabit tutulup, güç faktörünü ayarlamak suretiyle sistemden çekilen reaktif gücü azaltılmıştır.Uygun reaktif güç faktörünü parametrelerini ayarlamak için sisteme Benzetilmiş Tavlama yöntemi uygulanmış olup, optimum çalışma noktası belirlenmiştir. Üçüncü işlem olarak yük atma yöntemi uygulanmıştır. Mevcut sisteme ek sabit bir transformatör kademe değiştirici eklenerek sistem modellenmesi yapılmıştır. Test Sisteminde çalışan 4 adet DÜ'den biri saat 12:00 - 15:00 arasında diğeri ise saat 21:00 – 24:00 arasında devre dışı kalmıştır. Ayrıca gün boyunca Bara-7 ve Bara 16 'da önemli bir yük artışı olmuştur. Bu arıza durumuna göre sistemdeki gerilim seviyesini düzeltmek ve kayıpları azaltabilmek için belirlenen baralardan belirli bir oranda yük atılmıştır. Yük atma parametresi olarak yük şekli parametresi esas alınarak ,yük atma seviyesi en fazla %30 olarak belirlenmiştir. Baraların 24 saatlik yük tüketim değerlerine göre belirli bir satış fiyatı verilmiştir. Çok güç harcamanın karşılığı olarak daha düşük satış fiyatı belirlenmiştir.Sistemdeki problemi giderebilmek için göreceli önemsiz yükler belirlenmiştir. Bu yüklerden yük atabilmek için ,ilgili baralara yük atma karşılığında belirli bir ücret teklif belirlenip, ödeme fiyatı olarak, ilgili bara'nın satış fiyatının %20'si teklif edilmiştir. Kesinti karşılığında ödeme aralığı 0 ile 25 $/h arasında belirlenmiş olup, gerilim seviyeleri de normal çalışma limitlerine göre ayarlanmıştır. Yük atma için Bara-13, Bara-19, Bara-21 belirlenmiş olup, yüklerin ne kadar yük atabilmesini belirlemek için Benzetilmiş Tavlama algoritmasıyla sisteme 5 adet başlangıç parametresi verilip ,optimum çalışması noktası bulunmuştur.

Özet (Çeviri)

With the development of technology, the world has become more industrialized. This situation has increased the demand for energy. population growth has increased significantly in recent years due to new technologies, environmental concerns and user preference. In addition to this, there is also serious fluctuation during the day in the demand of electricity. To meet demand, electricity companies either increase their output or buy electricity from a wholesale market with a dynamic pricing structure. Such an operation leads to a low load factor (ratio of average load to peak load). From this point; it has been a remarkable research and application area in recent years that the control axioms are shifted to the consumer side by production, rather than to the management of the production according to the student, in particular the demand power is managed to decrease the peak demand. In this thesis, the necessary methods to remove the disruptive effects that would prevent the operation of the system in case of malfunctions in distribution systems were studied. In this study incentive based demand response program, in which consumers are included, was used. Faults that may occur in the square are considered as a single-purpose optimization problem and this problem is solved through the proposed algorithm under certain constraints. In the applied optimization method, the main purpose is to ensure that the voltage level in the bar is appropriate under normal operating conditions. In addition, minimizing power losses in the power system is another purpose of this thesis. In this context, Simulated Annealing Algorithm which is one of the intuitive optimization methods is used. This algorithm was developed in the MATLAB environment. When the boundary voltage profiles are considered as inequality constraint, the decision variables are the transformer tap changer, the power factor of the distributed generation systems and the load curve characteristics of the buses to be loaded. A balanced distribution system with 23 bus was used as the test system. This test system was utilized in the modeling of the OpenDSS simulation program. In this program, the test system data used is arranged so that the daily load flow based on the fixed point iteration method is performed. Loads in bars are modeled as constant strength and reactive and active power constraints are defined here. In order to evaluate the performance of the proposed method, many studies have been carried out to make corrections in the system according to the possible emergency conditions. Three corrections have been applied to the beloved test system. The first correction is achieved by setting the transformer setting level. In the present test system, the transformer was initially deactivated and the load flow was made. Active power loss, reactive power loss, single phase voltage profile and cost functions of objective functions are determined considering that there are no faults in the system. One of the 4 DGs working in the Test System was disabled between 16:00 and 21:00 hours. In addition, a load increase was observed at Bus-23 between 12:00 and 18:00. Only the transformer tap changer is added to the system in order to regulate the voltage profile and reduce the losses in the faulty system. The transformer tap changer is optimized between -10 and +10 and the voltage level is regulated. The second method is reactive power planning. System modeling has been done by adding a fixed transformer tap changer to the existing system. One of the 4 DGs working in the Test System was disabled between 12:00 - 15:00 hours and the other between 21:00 - 24:00 hours. Also during the day Bus-7 and Bus 16 had a significant pay rise. In order to correct the voltage level in the system and reduce the losses according to this fault condition, the reactive power drawn from the system is reduced by keeping the active power of the two DGs constant and adjusting the power factor. Simulated annealing method is applied to the system to adjust the parameters of the optimum reactive power factor. It has been identified. The third method is the load curtailment method. System modeling has been done by adding a fixed transformer setting changer to the existing system. One of the 4 DGs working in the Test System was disabled between 12:00 - 15:00 hours and the other between 21:00 - 24:00 hours. Also during the day Bus-7 and Bus 16 had a significant pay rise. In order to correct the level of voltage in the system and to reduce the losses according to this fault condition, a certain load was curtailed from the determined buses. Based on the load shape parameter as the load curtailment parameter, the load curtailment level is set at maximum 30%. A specific sale price is given according to the 24-hour load consumption values of the buses. A lower selling price has been set aside for spending too much power. Relatively unimportant loads have been identified to alleviate the problem in the system. In order to be able to pay for these loads, a specific fee offer has been determined for the relevant bus loads and the price of the bid has been offered at 20% of the sales price of the relevant buses. The payout interval for the interruption is set between 0 and 25 $ / h, and the voltage levels are set according to normal operating limits. Bus-13, Bus-19, Bus-21 were determined for loading and 5 parameters were given to the system with the Simulated Annealing algorithm to determine how much load can be loaded, and the optimum working point was found. The following results have been achieved with this thesis study.Voltage surges and distribution system power losses can be effectively reduced when distributed production units are added to the system. But the effect on voltage regulation and the size and location of the DG must be studied carefully.When the transformer is added to the system together with the DG, the worst case reduction of voltage regulation and power losses is further increased. Thus, central optimal control during system planning as well as the effective operation of these system components together is necessary to operate under stronger conditions.Voltage surges and power losses associated with the DGs connected to the Feeder's lower buses are less than those connected to the buses at the top of the federation. Better voltage profile and reduced power losses are related to the spread rate of the DG to the system (frequency of use).Different system planning for different types of DGs (Photovoltaic-Wind Turbine etc.) is required. The addition of the transformer tap changer has a significant effect on the voltage regulation and accordingly, it is better to work with other devices in combination.The demand response methods reduce the voltage drop of the feeders in the distribution system and increase the voltage level at the end of the bus.The types of Demand Response methods can vary depending on the type of failure and the load on the system. If there is a fault in the system, if the current fault is lighter, and there is no or less load in the system, the transformer tap changer can be used to reduce losses and voltage regulation can be maintained under normal conditions. If the fault in the system is slightly larger and loads are increasing, in addition to the current fixed transformer setting stage, if the active power of the working distributed generators (DG) in the system is kept constant and the reactive power is reduced, both loss can be reduced and voltage can be regulated. If the fault size in the system is too large to be solved by the previous methods and the loads in the system are too high, a certain load disposal agreement can be made with those who use the most appropriate load to load in the distribution systems and the losses can be reduced and voltage can be kept under normal conditions. Various optimization methods (classical, intuitive) can be applied to the problem of minimizing the stress profile and the losses in the evaluation of certain constraints and the objective function.Used as a single-purpose optimization method, SA can easily and efficiently deliver optimum candidate results.

Benzer Tezler

  1. Elektrik güç sistemlerinin dayanıklılığın artırılması için yeni bir optimizasyon tabanlı yaklaşımın geliştirilmesi

    Development of a new resiliency-driven optimization-based algorithm for electrical power systems

    AYŞE KÜBRA ERENOĞLU

    Doktora

    Türkçe

    Türkçe

    2021

    Elektrik ve Elektronik MühendisliğiYıldız Teknik Üniversitesi

    Elektrik Mühendisliği Ana Bilim Dalı

    PROF. DR. OZAN ERDİNÇ

  2. Uncapacitated multiple allocation hub location problem under congestion

    Trafik sıkışıklığı altında çok atamalı kapasite kısıtsız ana dağıtım üssü yerleşim problemi

    ÇAĞRI ÖZGÜN KİBİROĞLU

    Doktora

    İngilizce

    İngilizce

    2019

    Endüstri ve Endüstri Mühendisliğiİstanbul Teknik Üniversitesi

    Endüstri Mühendisliği Ana Bilim Dalı

    PROF. DR. YUSUF İLKER TOPCU

  3. A blood distribution system: An application to the Turkish Red Crescent

    Kan dağıtım sistemi: Türk Kızılayı için bir uygulama

    ATIL KURT

    Doktora

    İngilizce

    İngilizce

    2018

    Endüstri ve Endüstri MühendisliğiOrta Doğu Teknik Üniversitesi

    Endüstri Mühendisliği Ana Bilim Dalı

    PROF. DR. MERAL AZİZOĞLU

    DOÇ. DR. FERDA CAN ÇETİNKAYA

  4. A novel artificial intelligence based energy management system for microgrids

    Mikro şebekeler için yapay zeka temelli yeni bir enerji yönetim sistemi

    NECATİ AKSOY

    Doktora

    İngilizce

    İngilizce

    2023

    Elektrik ve Elektronik Mühendisliğiİstanbul Teknik Üniversitesi

    Elektrik Mühendisliği Ana Bilim Dalı

    PROF. DR. VEYSEL MURAT İSTEMİHAN GENÇ

  5. Doğalgaz basınç düşürme ve ölçüm istasyonları (RMS-A) kokulandırma sistemlerinin çevresel etkilerinin incelenmesi

    Investigation of environmental impacts of odorization systems in natural gas pressure reducing and metering stations (RMS-A)

    HASAN SARIKAYA

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    Çevre Mühendisliğiİstanbul Teknik Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    PROF. DR. İSMAİL TORÖZ

    DR. ÖĞR. ÜYESİ CEVAT ÖZARPA