Bronkoalveolar lavaj sıvısında hücre sayımının farklı metotlar arasında karşılaştırılması
Comparison of the different methods for counting cell in the bronchoalveolar lavage fluid
- Tez No: 521894
- Danışmanlar: DOÇ. DR. BÜLENT ALTINSOY
- Tez Türü: Tıpta Uzmanlık
- Konular: Göğüs Hastalıkları, Chest Diseases
- Anahtar Kelimeler: Bronkoalveolar lavaj, diferansiyel hücre sayımı, optik mikroskopi, akım sitometr, Akım sitometrisi, Bronkoalveolar lavaj sıvısı, Göğüs hastalıkları, Hücre farklılaşması, Mikroskopi, Mikroskopi-ışık, Teşhis, Teşhis teknikleri ve prosedürleri, Bronchoalveolar lavage, differential cell count, optical microscopy, flow cytometry, Bronchoalveolar lavage fluid, Thoracic diseases, Cell differentiation, Microscopy, Microscopy-polarization, Diagnosis, Diagnostic techniques and procedures
- Yıl: 2018
- Dil: Türkçe
- Üniversite: Zonguldak Bülent Ecevit Üniversitesi
- Enstitü: Tıp Fakültesi
- Ana Bilim Dalı: Göğüs Hastalıkları Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç: Bronkoalveolar lavaj (BAL) sıvısı diferansiyel hücre paterni, diffüz parankimal akciğer hastalıklarının tanısal yaklaşımında ve ayırıcı tanıları daraltmada kullanılmaktadır. Bu çalışmanın amacı optik mikroskopiye göre daha hızlı ve daha objektif bir yöntem olan akım sitometri (FCM) ile BAL hücresel profilinin elde edilmesi ve sonuçlarının optik mikroskopi ile elde edilenle karşılaştırılarak optik mikroskopi yerine kullanımının uygunluğunu ya da üstünlüklerini belirleyebilmekti. Gereç ve Yöntem: Araştırma 2017 ve 2018 yılında difüz parankimal akciğer hastalığı nedeni ile tanı amaçlı bronkoalveolar lavaj uygulanan ve BAL sıvıları hem optik mikroskopta hem de FCM cihazında analiz edilen hastalar geriye dönük olarak incelenerek yapıldı. Bulgular: Wilcoxon işaretli sıra testi ile FCM ve optik mikroskopideki lenfosit ve eozinofil sayıları arasındaki farkların anlamlı olduğu görüldü (sırasıyla p=0.005, p=<0.001). Bununla birlikte hem alveolar makrofajlar hem de nötrofillerde FCM ve optik mikroskopi arasındaki fark anlamlı değildi (sırasıyla p=0.820, p=0.280). Bland-Altman analizi ile akım sitometrinin optik mikroskopi ile karşılaştırıldığında lenfosit sayılarını %34.4 oranında ve yine nötrofil sayısını %14 oranında düşük tahmin ettiğini belirledik. Bununla birlikte alveolar makrofaj popülasyonlarının dağılımı homojendi. Çok değişkenli nokta ve çizgi diyagramları, sayılan eozinofiller hesaba katıldığında eozinofiller için akım sitometri ile optik mikroskopi arasında belirgin bir fark olmadığını gösterdi. Sonuç: Çalışmamız, uygun klinik şartlar ve ulaşılabilirlik durumunda daha hızlı sonuç veren ve alveolar hücre popülasyonunu daha iyi yansıtabilen FCM nin BAL sıvısının diferansiyel hücre profili analizinde güvenli olarak kullanabileceğini işaret etmektedir.
Özet (Çeviri)
Objectives: Differential cell pattern of bronchoalveolar lavage (BAL) fluid is used in the diagnostic approach of diffuse paranchymal lung diseases and in narrowing the differential diagnoses. The purpose of this study is to obtain the cellular profile of the BAL fluid by flow cytometry which is faster and more objective compared to optical microscopy and to determine the suitability or advantage of using flow microscopy instead of optical microscopy. Materials and Methods: The study was performed by retrospectively reviewing on patients who underwent bronchoalveolar lavage for diagnostic purpose due to diffuse parenchymal lung disease between 2017 and 2018, and whose BAL fluids were analyzed both in optical microscopy and in flow cytometry device. Findings: Wilcoxon signed rank test showed significant differences between FCM and optical microscopy in terms of the number of lymphocyte and eosinophil (p=0.005, p=<0,001 respectively). However, the difference between FCM and optical microscopy interms of both the number of alveolar macrophages and the number of neutrophils is not significant (p=0.820, p=<0,280 respectively). With Bland-Altman analysis, we found that flow cytometry predicts the number of lymphocyte by 34.4% and the number of neutrophil by 14% lower, when compared to optical microscopy. However, the distribution of alveolar macrophage populations was homogeneous. Multivariate point and line diagrams show that there is no significant difference between flow cytometry and optical microscopy for eosinophils when eosinophils are considered. Results: Our study indicates that in the case of appropriate clinical conditions and accessibility, FCM which provides faster results and better reflect the alveolar cell population can be used safely in differential cell profile analysis of BAL fluid.
Benzer Tezler
- Therapeutic potential of an immunosuppressive oligodeoxynucleotide encapsulated within liposomes on bleomycin-induced mouse model of lung inflammation and fibrosis
Lipozoma yüklenmiş immünbaskılayıcı bir oligodeoksinükleotidin bleomisin ile farede oluşturulmuş akciğer enflamasyonu ve fibrozu üzerindeki tedavi edici potansiyeli
GİZEM KILIÇ
Yüksek Lisans
İngilizce
2019
Romatolojiİhsan Doğramacı Bilkent ÜniversitesiMoleküler Biyoloji ve Genetik Ana Bilim Dalı
PROF. DR. İHSAN GÜRSEL
- Endokannabinoid metabolizmasının inhibisyonunun alerjik solunum yolu inflamasyonunda yeni bir tedavi stratejisi olarak incelenmesi
Examination of endocannabinoids metabolism inhibition as a new target in the treatment of allergic airway inflammation
RESHED ABOHALAKA
Doktora
Türkçe
2024
Eczacılık ve FarmakolojiHacettepe ÜniversitesiFarmakoloji Ana Bilim Dalı
PROF. DR. TURGUT EMRAH BOZKURT
- Preparation and characterization of magnetic nanoparticles with anchored antibodies for biomarker separation from body fluids
Vücut sıvılarından biyogösterge ayrımı için antikor bağlı magnetik nanopartikül üretimi ve karakterizasyonu
ELVAN DEMİRBAĞ
Yüksek Lisans
İngilizce
2013
Kimya Mühendisliğiİstanbul Teknik ÜniversitesiKimya Mühendisliği Ana Bilim Dalı
PROF. DR. ÖZGÜL ÖZCAN TAŞPINAR
PROF. DR. PETR KACER
- Romatoid artrit ve sistemik sklerozlu hastalarda bronkoalveolar lavaj sıvısında lenfosit subgruplarının değerlendirilmesi
Başlık çevirisi yok
ŞEBNEM ATAMAN
Tıpta Uzmanlık
Türkçe
1994
Endokrinoloji ve Metabolizma HastalıklarıAnkara Üniversitesiİç Hastalıkları Ana Bilim Dalı
DOÇ.DR. GÜLAY KINIKLI
- Akciğer kanserli olgularda serum ve bronkoalveolar lavaj sıvısında matriks metalloproteinaz-2 ve matriks metalloproteinaz doku inhibitörü-2 düzeylerinin tümör belirleyicisi olarak değerlendirilmesi
Evaluation of levels of serum and brochoalveolar lavage fluit matrix metalloproteinase-2 and tissue inhibitor of metalloproteinase-2 as tumor markers of lung cancer subjects
DEFNE ÖZBEK