Geri Dön

İntrapartum fetal kalp hızı traselerinin neonatal sonuçlar ile ilişkisi

The relationship between intrapartum fetal heart rate trace and neonatal results

  1. Tez No: 551158
  2. Yazar: EMRAH BEYAN
  3. Danışmanlar: DOÇ. DR. SEFA KURT
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Kadın Hastalıkları ve Doğum, Obstetrics and Gynecology
  6. Anahtar Kelimeler: fetal kalp hızı trasesi, umbilikal arter pH, erken neonatal sonuçlar, fetal heart rate tracing, umblical artery pH, early neonatal outcomes
  7. Yıl: 2013
  8. Dil: Türkçe
  9. Üniversite: Sağlık Bilimleri Üniversitesi
  10. Enstitü: İzmir Tepecik Eğitim ve Araştırma Hastanesi
  11. Ana Bilim Dalı: Kadın Hastalıkları ve Doğum Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

GİRİŞ ve AMAÇ: Amerika Birleşik Devletleri Ulusal Çocuk Sağlığı ve İnsani Gelişme Enstitüsü (NICHD) kategorilerine göre intrapartum fetal kalp hızı traseleri ile erken neonatal sonuçlar arasındaki ilişkiyi saptamak. YÖNTEM ve GEREÇLER: 150 tekil, sefalik prezentasyonda, komplikasyonsuz gebelik NICHD kategorilerine göre değerlendirildi. 110- 160 atım/ dk arasında baseline ve varyabilitesi olan, geç ya da varyabıl deselerasyon içermeyen kategori 1 traseler; Grup 1 olarak tanımlandı. Varyabilite kaybı ile birlikte tekrarlayan geç ve varyabıl deselerasyon veya bradikardinin eşlik ettiği kategori 3 traseler ise; Grup 3 olarak tanımlandı. Bunların dışında kalan ve her iki kategoriyi tam olarak karşılamayan kategori 2 traseler ise Grup 2 olarak tanımlandı. Gruplar, doğum şekilleri, 1. ve 5. dk. APGAR skorları, umbilikal kordon kan gazı pH değerleri, mekonyumlu amniyon mayi varlığı ve yenidoğan yoğun bakım ünitesi (YDB) gereksinimi açısından karşılaştırıldı. BULGULAR: Her kategoride 50 hasta çalışmaya dahil edildi. Grup 2 ve Grup 3' de, Grup 1'e göre, UA pH değerinin, 1. dk APGAR skorunun istatistiksel anlamlı olarak daha düşük olduğu saptandı (p< 0,05). Grup 3' ün, Grup 2 ve 1'e göre sezaryen oranının, mekonyumlu amniyon mayi varlığının daha fazla olduğu istatistiksel olarak tespit edilmiştir (p< 0,05). YDB gereksinimi ve 5. dk APGAR skorlarında istatistiksel farklılık tespit edilmemiştir (p> 0,05). TARTIŞMA ve SONUÇ: İntrapartum FKH traselerine göre, erken neonatal sonuçları öngörmede 2008 NICHD kategorileri güvenli, etkin ve geçerli bir non-invaziv metottur.

Özet (Çeviri)

INTRODUCTION: To determine the relationship between early neonatal outcomes and intrapartum fetal heart rate tracings according to the United States of America National Institute of Child Health and Human Development (NICHD) METHODS: 150 single, cephalic presentation and non-complicated pregnants have been evaluated according to the categories of NICHD. Category 1, which has 110-160 pulse/min baseline and variability also not having late and variable deceleration, was defined as group 1. Category 3 traces, which having late and variable deceleration or bradycardia, were defined as group 3. Except those, category 2 traces, that not to fit in both categories are mentioned before, were defined group 2. Groups were compared to types of borns, 1. And 5. min. APGAR scores, umbilical cords blood gas pH values, being amnion fluid with meconium and the need for newborn intensive care unit. RESULTS: 50 patients were included in each category. İt was determined, in group 2 and group 3 UA pH values and 1 min. APGAR scores were statical meaningly lesser than group 1 (p< 0.05). Also, group 3 rates of cesarian and amnion fluid with meconium were statically higher than group 1 and 2 (< 0.05). There is no statically differences between needing for newborn intensive care unit and 5. min. APGAR scores (p> 0.05). DISCUSSION AND CONCLUSION: According to intrapartum fetal heart rate traces, 2008 NICHD categories are safe, effective and valid a non-invasive test for forecasting early neonatal results.

Benzer Tezler

  1. Elektronik fetal kalp hızı monitörizasyonu: Normal monitör, fetal stres, fetal distres ile ilişkili erken neonatal sonuçlar

    Başlık çevirisi yok

    NADİR COMART

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2006

    Sağlık Bakanlığı

    Çocuk Sağlığı ve Hastalıkları Ana Bilim Dalı

    Yükleniyor...

  2. Kategori II FHR trasesine sahip fetüslerin erken neonatal sonuçlarının incelenmesi

    Investigation of early neonatal results of fetuses with category II FHR trace

    FATMA BETÜL ŞAHİN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2022

    Sağlık Bilimleri Üniversitesi

    Kadın Hastalıkları ve Doğum Ana Bilim Dalı

    Yükleniyor...

  3. Düşük riskli term tekil gebeliklerde intrapartum fetal kardiyotokografi değerlendirmesinin neonatal kötü obstetrik sonuçlarla ilişkisinin prospektif araştırılması

    A prospective investigation of the association between intrapartum fetal cardiotocography evaluation and adverse neonatal outcomes in low-risk term singleton pregnancies

    CANSU DAĞ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2025

    Sağlık Bilimleri Üniversitesi

    Kadın Hastalıkları ve Doğum Ana Bilim Dalı

    Yükleniyor...

  4. İntrapartum monitorizasyonda internal ve eksternal yöntem karşılaştırılması

    Comparison of intrapartum internal and external fetal monitorization

    TAHİR HAKAN ERDEM

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1997

    Çukurova Üniversitesi

    Kadın Hastalıkları ve Doğum Ana Bilim Dalı

    Yükleniyor...

  5. Doğum eylemi sırasında kullanılan kablosuz fetal izlemin kadının konforu, doğum ağrısı ve doğum memnuniyeti üzerine etkisi

    The effect on women's comfort, birth pain and birth satisfaction of wireless fetal monitoring used during labor

    DEMET ÇAKIR

    Doktora

    Türkçe

    Türkçe

    2022

    Sivas Cumhuriyet Üniversitesi

    Ebelik Ana Bilim Dalı

    Yükleniyor...