Geri Dön

Giyilebilir teknolojiler kalp atımı ölçümünde yeterince hassas mı: Fitbit charge™ 2' örneği

Are wearable technologies sufficiently sensitive in heart rate measurement: The fitbit charge™ 2' example

  1. Tez No: 576641
  2. Yazar: OĞULHAN KAYABAŞ
  3. Danışmanlar: DOÇ. DR. MUTLU CUĞ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Spor, Sports
  6. Anahtar Kelimeler: Egzersiz Şiddeti, Giyilebilir Teknolojiler, Kalp Atım Hızı, Yo-Yo Aralıklı Toparlanmalı Koşu Testi, Egzersiz, Giyilebilir teknoloji, Kalp, Kalp hızı, Koşu, Spor, Testler, Yo-yo aralıklı toparlanma testi, Exercise Intensity, Wearable Technologies, Heart Rate, Yo-Yo Intermittent Recovery Running Test, Exercise, Wearable technology, Heart, Running, Sports, Tests, Yo-yo intermittent recovery test
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: Sivas Cumhuriyet Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Beden Eğitimi ve Spor Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmanın amacı; giyilebilir teknolojilerin bir ürünü olan 'Fitbit Charge™ 2 Heart Rate' isimli kalp atım hızı ölçümü yapan cihazın, 'Polar M400' Saati (altın standart) karşısında belirli kalp atım hızı şiddetlerinde (%70, %80, %90 ve %100) doğru ve geçerli veriler verip vermediğinin tespit edilmesidir. Bu araştırma, yarı deneysel ve kontrol grubu olmayan bir çalışmadır. Araştırma, Erzincan Binali Yıldırım Üniversitesi spor salonunda BESYO öğrencilerinin katılımı ile gerçekleştirilmiştir. Çalışmaya Erzincan Binali Yıldırım Üniversitesi, Beden Eğitimi ve Spor Yüksekokulu öğrencisi, hentbol ve futbol branşlarından 25'i bayan ve 25'i erkek olmak üzere toplam 50 birey (Yaş: 21.20±1.20 yıl, Boy: 1.73±5.31 cm, Kilo: 66.49±5.30 kg) katılmıştır. Fitbit Charge™ 2 cihazının, Polar Saat karşısındaki geçerliliğini test etmek maksadıyla, çalışmaya katılan bireylerin sol el bileğine Fitbit Charge™ 2 cihazı, sağ el bileğine ise Polar Saat takılmıştır. Sonrasında ise bireyler 'Yo-Yo Aralıklı Toparlanmalı Koşu Testi (Yo-Yo Intermittent Recovery Test)'ine tabi tutularak; maksimum kalp atım hızlarının %70, %80, %90 ve %100'üne denk gelen belirli egzersiz şiddetlerindeki kalp atım hızları ölçülmüştür. Elde edilen veriler dijital ortama aktarılarak SPSS v.22 istatistik programıyla analiz edilerek yorumlanmıştır. Anlamlılık düzeyi (p<0.05) alınmıştır. Verilerin değerlendirilmesinde frekans ve yüzdelik değerler, One Sample t Testi, Bland-Altman Analizi, Sınıf içi Korelasyon Katsayısı (ICC) ve Pearson Korelasyon Katsayısı kullanılmıştır. Araştırmadan elde edilen sonuçlara göre; bireylerin %70 (Polar: 136 atım/dk - Fitbit: 104 atım/dk), %80 (Polar: 154 atım/dk - Fitbit: 113 atım/dk), %90 (Polar: 170 atım/dk - Fitbit: 118 atım/dk) ve %100 (Polar: 188 atım/dk - Fitbit: 123 atım/dk)'ün deki maksimum kalp atım hızı ölçümlerinden elde edilen Polar Saat verileri ile Fitbit Charge™ 2 cihazından elde edilen veriler arasında istatistiksel olarak anlamlı farklılıklar bulunmuştur. Bu sonuçlara göre, Fitbit Charge 2 cihazının kullanımı sporcu sağlığı ve gelişimi açısından uygun değildir.

Özet (Çeviri)

The aim of this study is to determine whether or not the heart rate measurement device 'Fitbit Charge ™ 2 Heart Rate', a product of wearable technologies, provides valid and acceptable data at specific heart rates (70%, 80%, 90% and 100%) when compared to 'Polar M400' (gold standard). This study is semi-experimental and there is no control group. The research was conducted in Erzincan Binali Yıldırım University gymnasium with the participation of the students studying in the School of Physical Education and Sports. A total of 50 students (25 female and 25 male) from handball and football branches participated in the study (age: 21.20 ± 1.20 years, height: 1.73 ± 5.31 cm, weight: 66.49 ± 5.30 kg). To test the validity of the Fitbit Charge ™ 2 device against the Polar Watch, the participants wore the Fitbit Charge ™ 2 devices on their left wrists and Polar watches on the right. Then, the individuals had the Yo-Yo Intermittent Recovery Test. Their heart rates at specific exercise intensities, corresponding to 70%, 80%, 90% and 100% of their maximum heart rates, were measured. SPSS v.22 statistics program was used to analyse the data. Significance level was regarded as (p <0.05). Frequency and percentage values, One Sample t Test, Bland-Altman Analysis, In-Class Correlation Coefficient (ICC) and Pearson Correlation Coefficient were used to evaluate the data. The results of the study show that there are statistically significant differences between the Polar watch data and Fitbit Charge ™ 2 device with regards to the maximum heart rate measurement of the 70% (Polar: 136 beats / min - Fitbit: 104 beats / min), 80% (Polar: 154 beats / min - Fitbit: 113 beats / min), 90% (Polar: 170 beats / min - Fitbit: 118 beats / min), and 100% (Polar: 188 beats / min - Fitbit: 123 beats / min) of the participants. According to the results, the use of Fitbit Charge 2 device is not suitable for athletes' health and their improvement.

Benzer Tezler

  1. Enerji iletim şebekelerinin donanım planlamasında optimizasyonu

    Optimisation in the planning of supply of power transmission networks summary

    K.R.İRFAN GÜNEY

    Doktora

    Türkçe

    Türkçe

    1987

    Elektrik ve Elektronik MühendisliğiMarmara Üniversitesi

    DOÇ. DR. NESRİN TARKAN

  2. Çeviri dersinde yapılaşma (uygulama sorunları-yöntem önerileri)

    Strukturierung im übersetzungsunterricht (probleme der praxis-vorschlage zur methodik)

    A. TURGAY KURULTAY

    Doktora

    Türkçe

    Türkçe

    1989

    Eğitim ve Öğretimİstanbul Üniversitesi

    Alman Dili ve Edebiyatı Bilim Dalı

    PROF.DR. ŞARA SAYIN

  3. Fotoğraf ve gerçeklik

    Photography and reality

    İHSAN DERMAN

  4. Küme örneklemesinde alt örnekleme yöntemi ve sonuçlara etkisi

    Başlık çevirisi yok

    İLKER ETİKAN

    Yüksek Lisans

    Türkçe

    Türkçe

    1989

    İstatistikHacettepe Üniversitesi

    Biyoistatistik Ana Bilim Dalı

    DOÇ. DR. VİLDAN SÜMBÜLOĞLU

  5. C-silindir lie grubu ve E3 üzerindeki C-etkisi

    C-cylinder lie group ad its C-action on the E3

    HALİT GÜNDOĞAN

    Doktora

    Türkçe

    Türkçe

    1990

    MatematikGazi Üniversitesi

    Matematik Ana Bilim Dalı

    YRD. DOÇ. DR. BÜLENT KARAKAŞ