Multiple-parameter optimization of the SLNSPECT/CT imaging protocol using montecarlo simulation for precision medicine

SPECT/CT görüntüleme protokolünükullanarak monte carlo simülasyonu ileSLN'in çoklu parametre optimizasyonu

  1. Tez No: 592448
  2. Yazar: HİLAL YILDIZ
  3. Danışmanlar: DOÇ. DR. ALBERT GÜVENİŞ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Biyomühendislik, Bioengineering
  6. Anahtar Kelimeler: sentinel lenf nodülü, SPECT/CT, kanser, sentinel lymph nodes, SPECT/CT, Monte Carlo simulation, breast
  7. Yıl: 2019
  8. Dil: İngilizce
  9. Üniversite: Boğaziçi Üniversitesi
  10. Enstitü: Biyomedikal Mühendislik Enstitüsü
  11. Ana Bilim Dalı: Biyomedikal Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Kadınlar arasında en çok görülen kanser türü meme kanseridir. Günümüzde ileri tedavi uygulamaları mevcuttur ve tedavinin etkisi erken teşhisle ilişkilidir. Memedeki sentinel lenf nodüllerinin belirlenebilirliği yayılma olmadan önce meme kanserini tahmin etmek hususunda önemli bir rol üstlenir. Bu çalışma SPECT/CT kullanarak memedeki sentinel lenf nodüllerinin taranması ve sentinel lenf nodüllerinin görüntü kalitesinin gelişmesini ve farklı parametrelerin optimum değerlerinin DOE metodu kullanarak bu￾lunmasını amaçlamıştır. Memedeki sentinel lenf nodüllerinin değerlendirilmesi için SIMIND Monte Carlo Simülasyon paketi ve DOE metodu kullanıldı. Kollar ve bacaklar olmaksızın Zubal gövde modellendi. Yayınlanmış kılavuzlar ve literatürdeki tipik görüntü şartları kullanıldı. OSEM algoritmaları rekonstrüksiyon için kullanıldı. Yedi parametre belirlendi. Bunlar zayıflama düzeltmesi (+; -), projeksiyon sayısı (120; 60), enerji penceresi (%20; %15), kolimatör türü (düşük enerji yüksek rezolüsyonlu (LEHR); düşük enerji genel amaçlı (LEGP)), yineleme sayısı (20; 10), altküme sayısı (15; 5) ve aktivitesiydi. 8 deneysel çalışmayla ortogonal bir dizi kullanıldı. Kontrastın gürültüye oranı hesaplandı. Sonuç tablosuna göre en yüksek kontrat gürültü oranı birinci deneyle 9.63 olarak bulundu. Bu sonuç LEHR kolimatör türü,120 projeksiyon sayısı, zayıflama düzeltmesi yapılarak, %20 enerji penceresi seçilerek, 20 yineleme ve 15 altküme sayısı kullanılarak ve yüksek aktivite kullanılarak elde edildi. İlk sonuçlara göre, kolimatör türü, projeksiyon sayısı ve zayıflama düzeltmesi görüntü kalitesi üzerinde en çok etkiye sahip olan parametreler olarak belirlendi.

Özet (Çeviri)

The most encountered cancer type among women is the breast cancer. Ad￾vanced clinical treatment applications are currently present, and the effectiveness of treatment is closely related to early diagnosis. Detectability of sentinel lymph nodes (SLNs) in breast assumes noteworthy role in order to predict breast cancer before metastasis. This study intended to scan SLNs in breast by using SPECT/CT and to enhance image quality of SLNs and find out optimal values of different parameters by using the design of experiments methods. The SIMIND Monte Carlo Simulation package and Design of Experiments were used to evaluate SLNs in breast. A Zubal torso phantom was modelled. Typical imaging conditions were utilized from published guidelines and literature. The OSEM algorithms were used for reconstruction. Seven parameters were specified as attenuation correction(+ ; -), number of projections (120; 90), collimator type (low- energy-high-resolution (LEHR); low-energy-general-purpose (LEGP)), energy window (20%; 15%), iteration number (20; 10), subset ( 15 ; 5) and count activity. An orthogonal array with 8 experimental runs was used. Contrast-to￾noise ratios were calculated from lesion and background statistics. From the response table, the highest CNR value was found 9.63 with a combination of LEHR collimator type, attenuation correction, 20% energy window, 20 iterations, 15 subsets, 120 pro￾jections and higher count activity. According to results, collimator type, number of projections and attenuation correction had the highest effect. More research is needed to include other correction algorithms.

Benzer Tezler

  1. Realization of transmitter and receiver clock generation units and channel switching unit in a modified analog radio relay

    Değiştirilen bir analog radyodaki verici ve alıcı saat üretimi birimleri ve kanal anahtarlama biriminin gerçekleştirilmesi

    AYHAN BÜYÜKSEMERCİ

    Yüksek Lisans

    İngilizce

    İngilizce

    1987

    Elektrik ve Elektronik MühendisliğiOrta Doğu Teknik Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    DOÇ. DR. MURAT AŞKAR

  2. Çoklu amaçların çözümlemesinde amaç programlaması ile genelleştirilmiş ters yaklaşımı ve yem sanayiinde bir uygulama

    Goal programming and generalieed inverse approaches in the multi-objective analysis and application in feed industry

    HASAN BAL

    Doktora

    Türkçe

    Türkçe

    1986

    İstatistikGazi Üniversitesi

    İstatistik Ana Bilim Dalı

    DOÇ. DR. FEVZİ KUTAY

  3. Bölünüme bağlı olmayan varyans çözümlemesi çoklu karşılaştırmalar ve tarımda uygulamaları

    Distiribution-free analyis of variance multiple comparisons and applications in agriculture

    HAMZA GAMGAM

    Doktora

    Türkçe

    Türkçe

    1985

    İstatistikGazi Üniversitesi

    PROF. DR. ÖZKAN ÜNVER

  4. Regresyon analizi ve Türkiye üzerine bir deneme buğday üretiminin tahmini

    Başlık çevirisi yok

    MACİT MESUT ÖZMEN

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    İstatistikGazi Üniversitesi

    PROF. DR. ERGÜN KİP

  5. İhracatın sektörel analizine ilişkin fonksiyonel bir araştırma

    Functional research on analysis of sectoral export

    AYŞENUR TOPÇUOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    EkonomiGazi Üniversitesi

    PROF. DR. ALPTEKİN ESİN