Farklı boydaki implanlar arasında gövde uzunluğu artışının, gelen kuvvetler karşısındaki implant ve çevre kemik dokusunda oluşan stres dağılımının üç boyutlu sonlu elemanlar analizi yöntemiyle incelenmesi
Evaluation of stress distribution of the implant and surrounding bone against the forces on increased length of pontics supported by different length implants, using three-dimensional stress analysis
- Tez No: 645828
- Danışmanlar: PROF. DR. SUBUTAY HAN ALTINTAŞ
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2020
- Dil: Türkçe
- Üniversite: Karadeniz Teknik Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 149
Özet
Aşırı rezorbe kretlerde dental implantlar için yeterli kemik hacmi elde etmek bazı ek cerrahi işlemleri gerektirir. Kısa implantlar, kemik rekonstrüksiyonu amacıyla yapılan cerrahi tedavilerin risklerinden kaçınmak için kısıtlı kemik hacminde uygulanabilen alternatif bir tedavi seçeneğidir. Fakat standart implantlara göre çevre kemikle daha az yüzey teması olması nedeniyle uygulanımı tartışılmaktadır. Çalışmamızın amacı; kısa ve standart uzunluktaki implantlarla desteklenen sabit bölümlü protezlerin gövde uzunluğu artışının fonksiyonel kuvvetler altında çevre kemik, implant ve protetik yapılar üzerine etkisinin incelenmesi ve karşılaştırılmasıdır. Çalışmamızda 6 mm ve 12 mm boylarında, 4.2 mm çapında iki implantla desteklenen üç üyeli ve dört üyeli sabit bölümlü protez modellerine uygulanan vertikal ve oblik kuvvetler sonucu oluşan stresler, ANSYS 2019R2 sonlu elemanlar analizi paket programı ile değerlendirildi. Kortikal ve trabeküler kemik için maksimum ve minimum asal stres değerleri, implant ve tüm yapılar için Von Mises stres değerleri karşılaştırıldı. Ayrıca tüm yapılarda kuvvetler sonucu oluşan deformasyon görüntüleri yorumlandı. Oluşturulan dört üyeli implantüstü sabit bölümlü protez modellerinde, üç üyeli modellere göre tüm yapılarda daha yüksek stres değerleri elde edildi. İki gövde uzunluğunda da implant gövdesinde oluşan stres değerleri kısa implantta daha fazla meydana geldi. Çevre kortikal kemikte protez uzunluğundaki artışa bağlı kısa implantlarda daha yüksek stres değeri oluşurken, standart implantta bu etki bağlantı vidasında bulundu. Protez gövde uzunluğunun artması sonucunda oblik yüklemeler altında kısa ve standart implant çevresi kortikal kemikte ve standart implant bağlantı vidasında yüksek stres değerleri elde edildi. İmplant destekli dört üyeli sabit protezler için oblik kuvvetlerden kaçınılması gerektiği sonucuna varıldı.
Özet (Çeviri)
Some additional surgical procedures are required to obtain sufficient bone volume for dental implants in severely resorbed alveolar crest. Short implants are alternative treatment option for limited bone volume to avoid the risks of surgical treatment for bone reconstruction. However, its usage is controversial since it has less surface contact area with the surrounding bone than standard implants. The aim of our study to investigate and compare the effect of increased span length of short and standard length implant supported fixed partial prosthesis on the surrounding bone, implant and prosthetic structures under functional forces. The stresses which were generated under vertical and oblique forces on three and four unit fixed prosthesis supported with 6 mm and 12 mm length, 4.2 mm diameter implants were evaluated by using ANSYS 2019R2 finite element package program. The maximum principle stress and the minimum principle stress for cortical and cancellous bones, the Von Mises stress for implant and whole structures are used to compare stress. In addition, deformation images under forces were interpreted in all structures. In all models, higher stress values were observed for four-unit implant supported fixed prosthesis compared to three-unit models. The stress values for the implant body in both span lengths were higher in the short implant. Connected to increased prosthesis length greater stress value was occured in the surrounding cortical bone of short implants, while this effect was in the connection screw in the standard implant. Due to the increased prosthesis length high stress values were achieved for both the surrounding bone of short and standard implants and standard implant connection screw under oblique loads. It was concluded that oblique forces should be avoided for 4-unit implant supported fixed prosthesis.
Benzer Tezler
- Farklı boydaki implant abutmanlarına geçici siman ile simante edilen kuronların sökülebilmesi için gerekli vertikal çekme kuvvetlerinin ölçümü ve değerlendirilmesi
Başlık çevirisi yok
MEHMET ONUR KALAYCI
Yüksek Lisans
Türkçe
2007
Diş HekimliğiYeditepe ÜniversitesiOral İmplantoloji Ana Bilim Dalı
Y.DOÇ.DR. ÖZKAN CEM DİLEK
- Evaluation with finite element analysis of stresses generated by ımplants with different angles and lengths applied with the all on four technique in atrophic mandible
Atrofi̇k mandi̇bulada all on four tekni̇ği̇ i̇le uygulanan farkli açi ve boydaki̇ i̇mplantlarla oluşan stresi̇n sonlu elemanlar anali̇zi̇ i̇le değerlendi̇ri̇lmesi̇
TOURGKAI MOUSTAFA
Doktora
Türkçe
2024
Diş Hekimliğiİstanbul ÜniversitesiAğız Diş ve Çene Cerrahisi Ana Bilim Dalı
PROF. DR. GÜLSÜM AK
- Posterior maksillada uygulanan açılı implantların farklı açı, çap ve boydaki tasarımlarla uygulanmasının etkilerinin üç boyutlu sonlu elemanlar stres analiz yöntemi ile incelenmesi
The investigation of angled implants with different angle, diameter and length designs application on posterior maxilla using three dimensional finite element stress analysis method.
MELEK RAMOĞLU
Doktora
Türkçe
2015
Diş HekimliğiGaziantep ÜniversitesiAğız, Diş, Çene Hastalıkları ve Cerrahisi Ana Bilim Dalı
PROF. DR. METİN GÜNGÖRMÜŞ
PROF. DR. ERKAN ERKMEN
- Farklı boydaki hibrit ayçiçeği çeşitlerinde verim ve verim unsurları üzerinde araştırmalar
Başlık çevirisi yok
SAMİ SÜZER
- Soğan (Allium cepa L.) tohumu üretiminde kullanılan baş soğanların farklı dikim sistemlerinin tohum verimine etkileri
Seed yield effects of varying planting system of onion (Allium cepa L.) bulbs used in onion seed production
AHMET CANDAR
Yüksek Lisans
Türkçe
2013
ZiraatUludağ ÜniversitesiBahçe Bitkileri Ana Bilim Dalı
PROF. DR. ERDOĞAN BARUT
YRD. DOÇ. ALİ FUAT GÖKÇE