Geri Dön

Yüksek gerilim izolatörlerinin kirlenme atlama davranışlarının sonlu elemanlar yöntemi yardımıyla belirlenmesi

Determination of pollution flashover behaviour of high voltage insulators by the finite element method

  1. Tez No: 65868
  2. Yazar: MUHSİN TUNAY GENÇOĞLU
  3. Danışmanlar: DOÇ.DR. MEHMET CEBECİ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Elektrik ve Elektronik Mühendisliği, Electrical and Electronics Engineering
  6. Anahtar Kelimeler: Insulator, Finite Element Method, AR model, Pollution flashover, Pollution resistance
  7. Yıl: 1997
  8. Dil: Türkçe
  9. Üniversite: Fırat Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Elektrik-Elektronik Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 81

Özet

m ÖZET Yüksek Lisans Tezi YÜKSEK GERİLİM İZOLATÖRLERİNİN KİRLENME ATLAMA DAVRANIŞLARININ SONLU ELEMANLAR YÖNTEMİ YARDIMIYLA BELİRLENMESİ Muhsin Tunay GENÇOĞLU Fırat Üniversitesi Fen Bilimleri Enstitüsü Elektrik-Elektronik Mühendisliği Anabilim Dalı 1997, Sayfa: 81 Yüksek gerilim izolatörlerinin, enerji iletim sistemlerinde sürekli ve emniyetli bir yalıtım sağlaması istenir. Ancak izolatörlerin yüzeyinde oluşan kir tabakası, izolatörlerden beklenen performansı ve görevleri olumsuz yönde etkileyerek yüzeysel atlamalara ve dolayısıyla kısa devre arızalarına neden olur. Bu durum, enerji iletim problemlerinin en önemlilerinden biridir. Kirli bölgelerde kullanılacak izolatörlerin yüzeysel atlama performansını belirlemek üzere birçok tabii ve suni test yöntemleri geliştirilmiştir. Ayrıca modeller üzerinde analitik hesaplamalar yapılmıştır. İzolatör yüzeyinde oluşan kir tabakası, AR modeli ile temsil edilebilir. Bu model, izolatör yüzeyini sızma uzunluğu boyunca açarak bir düzlem haline getiren gerçek modeldir. İzolatörün yüzeysel atlama performansını belirleyen arka seri kir direncinin hesabı, modeller üzerinde ve bilgisayar yöntemleri kullanılarak yapılabilir. Bu çalışmada kirlenme atlamasının önemi, tanıtımı ve fiziksel mekanizması açıklanarak izolatörlerin atlama davranışlarının tabii ve suni testler yoluyla nasıl belirlendiği ve izolatör eşdeğer modelleri karşılaştırmalı olarak incelenmiştir. Ele alınan 5 tip izolatörün arka seri direnç değişimlerini hesaplamak üzere önce izolatörlerin AR modelleri ayrı ayrı bulunmuş ve bu modellere SEY uygulanarak direnç değişimleri bilgisayar yardımıyla hesaplanmıştır. Hesaplanan sonuçlar deneysel sonuçlarla karşılaştırılmıştır. ANAHTAR KELİMELER: İzolatör, Sonlu Elemanlar Yöntemi, AR modeli, Kirlenme atlaması, Kir direnci.

Özet (Çeviri)

IV SUMMARY Master Thesis Determination of Pollution Flashover Behaviour of High Voltage Insulators by The Finite Element Method Muhsin Tunay GENÇO?LU Fırat University Graduate School of Natural and Applied Sciences Department of Electrical and Electronics Engineering 1997, Page: 81 High voltage insulators are supposed to provide a continuous and safety insulation in energy transmission systems. However, pollution layer that occurs on the surface of insulator, decreases the performance of insulators and causes surface flashovers and therefore short circuit failures. Several natural and artificial test methods had been developed to determine the surface flashover performance of the insulators, which will be used in polluted region. In addition, analytical calculations have been carried out on the models. AR model can be used to model the surface pollution layer of the insulator. AR model is a real model that open the surface of the insulator along the leakage length to a plane. Calculation of the pollution resistance serial to the discharge which determines the surface flashover performance can be carried out on the models and using computer methods. In this work, pollution flashover and physical mechanism of it have been defined and its importance has been explained. Determination of the flashover behaviour of the insulators via natural and artificial tests and insulator equivalent models have been examined, comparatively. In order to calculate the variation of the resistance serial to the flashover, AR models of the insulators has been constructed seperately for 5 insulators that has been examined and later their resistance variations have been calculated applying FKM analysis to the models. Computational results are compared with the experimental results.

Benzer Tezler

  1. Computer-aided estimation of the flashover performance of polluted high voltage insulators

    Kirli yüksek gerilim izolatörlerinin atlama performanslarının bilgisayar destekli olarak belirlenmesi

    MEHMET EFE ÖZBEK

    Doktora

    İngilizce

    İngilizce

    2002

    Elektrik ve Elektronik MühendisliğiOrta Doğu Teknik Üniversitesi

    Elektrik ve Elektronik Mühendisliği Ana Bilim Dalı

    PROF. DR. AHMET RUMELİ

  2. Kirlenmiş yüksek gerilim izolatörlerine seri bağlı endüktansın yıldırım darbe dayanımına etkisi

    Effect of inductance in series with polluted high voltage insulators on lightning impulse withstand

    YUNUS BALCI

    Yüksek Lisans

    Türkçe

    Türkçe

    2021

    Elektrik ve Elektronik MühendisliğiFırat Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    PROF. DR. MEHMET CEBECİ

  3. Yüksek gerilim izolatörlerinde yüzeysel kaçak akımların anfıs ile hesaplanması

    Calculation of surface leakage current by anfis in high voltage insulator

    ERSİN TURAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2018

    Elektrik ve Elektronik MühendisliğiFırat Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    PROF. DR. MUHSİN TUNAY GENÇOĞLU

  4. Yüksek gerilim izolatörlerinde atlama olayının yapay sinir ağları kullanılarak incelenmesi

    Investigation of flashover phenomena on high voltage insulators using artificial neural network

    MUHSİN TUNAY GENÇOĞLU

    Doktora

    Türkçe

    Türkçe

    2003

    Elektrik ve Elektronik MühendisliğiFırat Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    PROF. DR. MEHMET CEBECİ

  5. Yüksek gerilim izolatörlerinde yüzeysel atlamanın azaltılması için yeni bir yaklaşım

    A new approach for reducing surface flashover in high voltage insulators

    HARUN GÜLAN

    Doktora

    Türkçe

    Türkçe

    2020

    Elektrik ve Elektronik MühendisliğiFırat Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    PROF. DR. MEHMET CEBECİ