Jeneratör kabininin panjurlarının boyutsal optimizasyonu ve kabinlerin sayısal ve deneysel analizlerinin karşılaştırılması

Dimensional optimization of the louvers of the generator cabinet and comparison of the numerical and experimental analysis of cabinet

  1. Tez No: 695853
  2. Yazar: BARBAROS MAZLUMCU
  3. Danışmanlar: PROF. DR. MUSTAFA ATMACA
  4. Tez Türü: Yüksek Lisans
  5. Konular: Makine Mühendisliği, Mechanical Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2021
  8. Dil: Türkçe
  9. Üniversite: Marmara Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Makine Mühendisliği Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Kabinli jeneratör setleri hem dış mekânda kullanıldığı hem de jeneratör setine koruma sağladıkları için tercih sebebidir. Jeneratör setine uygun bir kabin tasarlarken kullanılan motorun soğutma performansı, tasarım kriteri olarak belirlenmelidir. Bu çalışmada, kabinli bir jeneratör setinin hesaplamalı akışkanlar dinamiği yöntemiyle sayısal analizleri ANSYS FLUENT 19.2 yazılımında gerçekleştirilmiş ve gerçekleştirilen sayısal analizler, deneysel analizlerle karşılaştırılmıştır. Jeneratör kabininin panjurlarının optimum boyutlarını bulabilmek için, derinlik mesafeleri farklı, üç panjur aynı şartlarda analiz edilmiş ve panjurun giriş ve çıkış yüzeyleri arası basınç farkı düşük çıktığı için derinliği en büyük panjur optimum panjur olarak belirlenmiştir. Jeneratör emiş bölgesi ve atış bölgesi olarak ikiye ayrılmış ve her bir bölgenin akış analizleri gerçekleştirilmiştir. Havalandırma kesitleri için arı peteği ve dörtgen şekil olarak iki farklı şekil aynı sınır şartlarında analiz edilmiş ve basınç farkı düşük olan şekil, havalandırma kesitlerinin şekli olarak belirlenmiştir. Tüm sistemin basınç farkı 1104C-44TAG2 motorunun verisinde izin verilen basınç farkı değerinden 14,25 Pa yüksek çıkmıştır. Bu farkın jeneratörün çalışma şartlarını ne kadar etkilediğini anlamak için HIOKI test cihazıyla deneyler yapılmış ve jeneratör setinin çalışabileceği maksimum sıcaklığın 3,99 °C düştüğü gözlemlenmiştir. Böylece ileride yapılacak olan çalışmalara referans oluşturulmuştur.

Özet (Çeviri)

Generator sets having cabinet, are preferred because they are used outdoors and provide protection to the generator set. While designing the cabinet suitable for the generator group, the cooling performance of the engine should be determined as the design criterion. In this study, numerical analysis of a generator set with cabin were made using computational fluid dynamics method in ANSYS FLUENT 19.2 software and numerical analysis were compared in experimental analysis. To find the optimum dimensions of the louvers of the generator cabinet, three louvers with different depths were analysed under the same conditions, and the louver with the longest depth was determined as the optimum louver so the pressure difference was low. The generator set is divided into suction zone and discharge zone, and flow analysis of each zone are performed. Two different shapes for ventilation sections were analysed under the same boundary conditions and the shape with low pressure difference was determined as the shape of ventilation sections. The pressure difference of the whole system was 14,25 Pa higher than the pressure difference value allowed in the data of the 1104C-44TAG2 engine. To understand how much this difference affects the operating conditions of the generator, experiments were carried out with the HIOKI test device. It has been observed that the maximum operating temperature of the generator set has decreased by 3,99 °C. Thus, a reference was established for future studies.

Benzer Tezler

  1. Computer aided design of lumped and distributed broadband matching and filtering networks

    Başlık çevirisi yok

    ADNAN KÖKSAL

    Yüksek Lisans

    İngilizce

    İngilizce

    1987

    Orta Doğu Teknik Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  2. Transformatör sargılarında oluşan hızlı değişimli geçici olayların incelenmesi ve enerji iletim sistemlerinin modellenmesinde yeni bir yaklaşım

    Investigation of high speed transients on transformer windings and a new approach in modelling of energy transmission systems

    A.OĞUZ SOYSAL

    Doktora

    Türkçe

    Türkçe

    1985

    İstanbul Teknik Üniversitesi

    Yükleniyor...

  3. Emet kolemanitinin ferroelektrik özellikleri

    Ferroelectric properties of emet colemanite

    AHMET ALİ AKŞİT

    Doktora

    Türkçe

    Türkçe

    1985

    İstanbul Teknik Üniversitesi

    Yükleniyor...

  4. Partikül yüklü, eş eksenli iki jet için karışma ve yanma modeli

    A Mixing and combustion model for particle-laden confined coaxiol jets

    METİN ERGENEMAN

    Doktora

    Türkçe

    Türkçe

    1985

    İstanbul Teknik Üniversitesi

    Yükleniyor...

  5. Muntazam dalgaların sabit yatay iki paralel plakadan transmisyonu

    Transmission of regular waves through two fixed horizontal parallel plates

    A. FÜGEN TORAMAN

    Doktora

    Türkçe

    Türkçe

    1977

    İstanbul Teknik Üniversitesi

    Yükleniyor...