Electrical System Configurationfor Passive Nuclear Power Plants(DC Power System)
非能动核电厂电气系统配置(直流电源系统)(申请清华大学工程硕士专业学位论文)
- Tez No: 708522
- Danışmanlar: PROF. SHI ZHENGGANG, DOÇ. FENG YUPİNG
- Tez Türü: Yüksek Lisans
- Konular: Enerji, Elektrik ve Elektronik Mühendisliği, Energy, Electrical and Electronics Engineering
- Anahtar Kelimeler: passive design, electrical system, battery, DC Battery system
- Yıl: 2020
- Dil: İngilizce
- Üniversite: Tsınghua Unıversıty
- Enstitü: Yurtdışı Enstitü
- Ana Bilim Dalı: Belirtilmemiş.
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Özet yok.
Özet (Çeviri)
This study usually studies the electrical design and configuration of passive power plants. A passive nuclear power plant is a power plant with a passive safety design. Passive safety design technology has begun to be used in the structure of nuclear power plants with third and third-generation + power plants. Passive safety design relies on natural forces, such as natural gravity and cyclic forces. The power plant adopts a passive design for safety-related components, which has resulted in major changes to the electrical system of the nuclear power plant. To understand passive safety design, clear research has been conducted on AP1000 and AP600 nuclear power plants. Because the third generation began with the AP600 nuclear power plant. On the other hand, the Chinese version of AP1000, CAP1400, was studied. A major change in electrical design is the reduction in the number of components for active power operation. This decline is primarily targeted at safety-related components. As the number of active safety-related components has decreased, backup safety systems have become even more important for nuclear power plants. After that, in this study, the DC power system of the nuclear power plant, especially the DC battery system, was studied. The research of the DC battery system is divided into DC battery and charger. Main headings on how to choose the battery type, battery cell type, battery size calculation, and battery charger size. For battery size and charger calculations, IEEE 485 and 946 standards are used. It is calculated manually according to the standard. From a standard worksheet as a calculation example. These calculations can also be done with ETAP software.
Benzer Tezler
- Elektrik güç sistemlerinde elektrik kalitesinin analizi ve simülasyonu
Analysis and simulation of electric quality in electrical power systems
EMRULLAH OKUDUCU
Yüksek Lisans
Türkçe
2010
Yüzüncü Yıl ÜniversitesiElektrik-Elektronik Mühendisliği Ana Bilim Dalı
Yükleniyor...
- Çok yüzeyli süperiletken ve halbach dizilimli sürekli mıknatıslardan oluşan süperiletken manyetik kaldırma sisteminin donmuş görüntü modeli ile analizi
Analysis of magnetic lift system consisting of multisurface superconductor and halbach arrangement continuous magnets with frozen image model
AHMET FURKAN REİSOĞLU
Yüksek Lisans
Türkçe
2022
İstanbul Teknik ÜniversitesiElektrik Mühendisliği Ana Bilim Dalı
Yükleniyor...
- Numerıcal ınvestıgatıon of cam-shaped turbulators for an aır-cooled photovoltaıc/thermal (PVT) system
Hava soğutmalı fotovoltaik/termal (PVT) sistem için kam şeklindeki türbülatörlerin sayısal incelenmesi
MOHAMMED SULAIMAN JUBAIR
- Sürekli mıknatıslı akı anahtarlamalı generatörlerde elektromanyetik ve yapısal başarımı artırmaya yönelik katkılar
Contributions to enhancing the electromagnetic and structural performance of permanent magnet flux switching generators
UMUT TERZİ
Yüksek Lisans
Türkçe
2026
İstanbul Teknik ÜniversitesiElektrik Mühendisliği Ana Bilim Dalı
Yükleniyor...
- The behoavioral modeling and an application of SAR ADC
SAR ADC'nin davranışsal modeli ve uygulaması
MERİÇ ECE ZEDELİ
Yüksek Lisans
İngilizce
2018
İstanbul Teknik ÜniversitesiElektronik Mühendisliği Ana Bilim Dalı
Yükleniyor...