Multiple sklerozlu hastalarda desteksiz üst ekstremite egzersiz testi'nin (UULEX) geçerliliği ve güvenirliğinin araştırılması
Investigation of the validity and reliability of the unsupported upper extremity exercise test (UULEX) in patients with multiple sclerosis
- Tez No: 749618
- Danışmanlar: PROF. DR. NAİME EVRİM KARADAĞ SAYGI
- Tez Türü: Yüksek Lisans
- Konular: Fiziksel Tıp ve Rehabilitasyon, Fizyoterapi ve Rehabilitasyon, Physical Medicine and Rehabilitation, Physiotherapy and Rehabilitation
- Anahtar Kelimeler: Multiple skleroz, UULEX, geçerlik güvenirlik, endurans, Güvenilirlik ve geçerlilik, Multipl skleroz, Teşhis testleri, Ölçekler, Multiple sclerosis, UULEX, validity and reliability, endurance, Reproducibility of results, Diagnostic tests, Scales
- Yıl: 2022
- Dil: Türkçe
- Üniversite: Marmara Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Fiziksel Tıp ve Rehabilitasyon Ana Bilim Dalı
- Bilim Dalı: Nörolojik Rehabilitasyon Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç: Multiple sklerozlu (MS) hastalarda Desteksiz Üst Ekstremite Egzersiz Testinin (UULEX) geçerlilik ve güvenirliğinin araştırılmasıdır. Gereç ve yöntem: Çalışmaya MS tanılı 23 hasta dahil edildi ve Zamanlı 25 Adım Yürüme Testi (T25FW), Kol-omuz ve El Sorunları Anketi (DASH), Dokuz Delikli Tahta Testi (DDTT), dinamometre, Ashworth Skalası, Beck Depresyon Ölçeği, Borg Dispne Skalası, Multipl Skleroz Yaşam Kalitesi Enstrümanı-54 (MSQOL-54) ile değerlendirildi. Geçerliliğinin araştırılması için değerlendirme ölçütleriyle UULEX skorları arasındaki ilişki Spearman korelasyon analiziyle hesaplandı. UULEX bir değerlendirici tarafından başlangıçta, bir saat sonra ve bir hafta sonra olacak şekilde üç kez uygulandı. Güvenirliğin belirlenmesi için sınıf içi korelasyon katsayısı (ICC) ve Cronbach alfa katsayısı hesaplandı. Bulgular: UULEX ile MSQOL-54 bileşik fiziksel sağlık alt boyutu, DDTT, T25FW, DASH, omuz addüksiyonu ve boyun ekstansiyonu kas gücü arasında güçlü istatiksel anlamlı korelasyon saptandı (rho= 0,569, p= 0,005; rho= 0,552, p= 0,006; rho= 0,753, p= 0; rho= 0,557, p= 0,006; rho= 0,518, p= 0,011; rho= 0,578, p= 0,004). Ortalama UULEX süreler 7 dakika 37 saniye, kaldırılan ağırlık 0.42 kg, gelinebilen seviye 6.58 olarak bulundu. Gözlemci içi güvenirliğinde ICC değeri süre için ICC= 0,943; 95% CI, 0,889- 0,973, ağırlık için ICC= 0,816; 95% CI, 0,673-0,91 ve seviye için ICC= 0,962; 95% CI, 0,927-0,983 idi. Cronbach's alfa katsayısı süre, ağırlık, seviye için sırasıyla 0,98, 0,93 ve 0,99 olarak saptandı. Sonuç: UULEX MS hastalarında üst ekstremite endurans ve egzersiz kapasitesinin değerlendirilmesinde geçerli ve güvenilir bir testtir.
Özet (Çeviri)
Objective: To aim of this study is investigate validity and reliability of the Unsupported Upper Extremity Exercise Test (UULEX) in patients with multiple sclerosis (MS). Material and Methods: 23 patients diagnosed with MS were included in study and evaluated Timed 25-Step Walking Test (T25FW), Arm-Shoulder and Hand Problems Questionnaire (DASH), Nine-Hole Board Test (DDTT), dynamometer, Modified Ashworth Scale, Beck Depression Scale, Modified Borg Dyspnea Scale, Multiple Sclerosis Quality of Life Instrument-54 (MSQOL-54). Determine validity, relationship between evaluations and UULEX score was calculated by Spearman correlation analysis. UULEX was administered three times by evaluator at baseline, one hour and one week later. Reliability and consistency were calculated with intraclass correlation coefficient (ICC) and Cronbach's alpha coefficient. Results: Strong statistically significant correlation was found between UULEX and MSQOL-54 composite physical health sub-dimension, DDTT, T25FW, DASH, shoulder adduction, neck extension muscle strength (rho= 0,569, p= 0,005; rho= 0,552, p= 0,006; rho= 0,753 , p= 0; rho= 0,557, p= 0,006; rho= 0,518, p= 0,011; rho= 0,578, p= 0,004). Average UULEX times were 7 minutes 37 seconds, weight lifted was 0.42 kg, attainable level was 6.58. In intra-observer reliability, ICC value for time ICC= 0,943; 95% CI, 0,889-0,973, weight ICC= 0,816; 95% CI 0,673-0,91 and level was ICC= 0,962; 95% CI 0,927-0,983. Cronbach's alpha coefficient for duration, weight and level were found 0,98, 0,93 and 0,99 respectively. Conclusion: UULEX is a valid and reliable test for evaluating upper extremity endurance and exercise capacity in MS patients.
Benzer Tezler
- Pediatrik başlangıçlı Multipl Sklerozlu hastalarda desteksiz üst ekstremite egzersiz testinin yorgunluk ve endurans ile ilişkisinin araştırılması
Investigation of the relationship between unsupported upper-limb exercise test and fatigue and endurance in patients with pediatric-onset Multiple Sclerosis
NERGİZ DOĞAN BOY
Yüksek Lisans
Türkçe
2024
Marmara ÜniversitesiFiziksel Tıp ve Rehabilitasyon Ana Bilim Dalı
Yükleniyor...
- Realization of transmitter and receiver clock generation units and channel switching unit in a modified analog radio relay
Değiştirilen bir analog radyodaki verici ve alıcı saat üretimi birimleri ve kanal anahtarlama biriminin gerçekleştirilmesi
AYHAN BÜYÜKSEMERCİ
Yüksek Lisans
İngilizce
1987
Orta Doğu Teknik ÜniversitesiElektrik-Elektronik Mühendisliği Ana Bilim Dalı
Yükleniyor...
- Çoklu amaçların çözümlemesinde amaç programlaması ile genelleştirilmiş ters yaklaşımı ve yem sanayiinde bir uygulama
Goal programming and generalieed inverse approaches in the multi-objective analysis and application in feed industry
HASAN BAL
- Bölünüme bağlı olmayan varyans çözümlemesi çoklu karşılaştırmalar ve tarımda uygulamaları
Distiribution-free analyis of variance multiple comparisons and applications in agriculture
HAMZA GAMGAM
- Regresyon analizi ve Türkiye üzerine bir deneme buğday üretiminin tahmini
Başlık çevirisi yok
MACİT MESUT ÖZMEN