Kilovoltaj değişikliğinin alveoler kemik morfometrik ölçümlerine etkisinin mikro-bilgisayarlı ve dental volümetrik tomografi ile değerlendirilmesi

Comparison of the effects of changing the kilovoltage on alveolar bone microstructure measurements using dental volumetric and micro-computed tomography

  1. Tez No: 750292
  2. Yazar: OĞUZHAN BAYDAR
  3. Danışmanlar: DOÇ. DR. ERİNÇ ÖNEM
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2022
  8. Dil: Türkçe
  9. Üniversite: Ege Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Ağız, Diş ve Çene Radyolojisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 80

Özet

Amaç: Farklı kilovolt ile görüntülenen koyun mandibulalarına ait DVT görüntülerinde, trabeküler ve kortikal kemiğe ait morfometrik ölçümlerin altın standart olarak kabul edilen mikro-bilgisayarlı tomografi (mikro-BT) görüntüleri üzerindeki ölçümler ile karşılaştırılmasıdır. Gereç ve Yöntem: Beş dişli koyun mandibulasından elde edilen 45x100 mm boyutlarında trabeküler ve kortikal kemik içeren 10 adet alveoler kemik örneği hazırlandı. Kemik örnekleri önce mikro-BT ile sonra DVT ile 3 farklı kilovoltta (kVp) (80,85,90 kVp) görüntülendi. Elde edilen 40 görüntü (30 DVT, 10 mikro-BT) üzerinden trabeküler ve kortikal kemiği içeren 120 kemik görüntüsü oluşturuldu. Bu görüntüler üzerinden trabeküler ve kortikal kemik ölçümleri için ayrı ayrı standart ilgi alanları (Region of interest, ROI) (120 trabeküler; 120 kortikal) oluşturuldu. Kırk görüntüden elde edilen toplam 240 ROI üzerinde (30 görüntü x 6 ROI=180 DVT; 10 görüntü x 6 ROI= 60 mikro-BT) trabeküler kemiğin mikrostrüktürüne ait 5 (FB, BV,BV/TV,Tb.Th, Tb.Sp) kortikal kemiğe ait 2 adet (Tt.Ar,Co.Th) morfometrik ölçüm ImageJ programı kullanılarak gerçekleştirildi. Mikro-BT ölçümleri ile DVT'nin farklı kilovoltlarına ait ölçümlerin karşılaştırılması eşleştirilmiş t-testi ile gerçekleştirildi. Tüm ölçüm sonuçları için mikro-BT ve farklı kilovoltlarda elde edilen DVT arasındaki uyum düzeyi Bland-Altman analizi ile değerlendirildi. DVT'nin farklı kilovoltlarına ait ölçümlerin değerlendirilmesinde ise tek yönlü varyans analizi (ANOVA) kullanıldı. (p0,0001) Sonuç: Bulgularımız DVT'nin kemik kalitesinin değerlendirilmesinde önemli bir araştırma ve tanı aracı olma potansiyelini göstermektedir. Bununla birlikte hasta dozunu göz önünde bulundurarak en iyi diyagnostik kapasiteye sahip kVp düzeyinin belirlenmesi önem taşımaktadır.

Özet (Çeviri)

Aim: The aim is to provide the morphometric measurements which are the quantitative strucrural analyses of trabecular and cortical bone on dental volumetric tomography (DVT) images obtained at different kilovoltages, and to compare those finding with the morphometric measurements obtained on micro-computed tomography images which are considered as the gold standard. Material and Methods: Ten bone samples which were 45x100 mm in size and were obtained from five dentulouse sheep mandible were utilized in this study. Each of the bone samples were initally images with micro-CT and then, with DVT using three different kilovoltages (80,85,90 kVp). In order to us efor trabecular and cortical bone measurements, standard region of interests (ROIs) with 5x5 mm size were created both on the micro-CT and DVT images. A total of 30 DVT and 10 micro-CT images obtained with different kVp resulted with 40 images with 240 ROIs (30 images x 6 ROI=180 DVT; 10 images x 6 ROI= 60 micro-CT). Image analysis was performed using ImageJ software, including following parameters: Fractal dimension (FD),bone volume (BV), bone volume fraction (BV/TV), trabecular thickness (Tb.Th), trabecular seperation (Tb.Sp), cortical thickness (Co.Th) and total cross-sectional area (Tt.Ar). Micro-CT measurements and measurements of different kVp of DVT were compared with paired t-test. Bland-Altman plot analysis was used to evaluate the agreement between DVT obtained with 3 different kVps and micro-CT. Additionally, one-way ANOVA test was used to determine the differences between three kVp values. In all test, p was accepted as 0.0001. Results: All measurements that were performed on DVT images obtained at three different kVps were higher than micro-CT measurements, except for bone volume (BV). Statistically significant differences were observed among measurements from DVT and micro-CT regarding all variables (parameters) (p0,0001). Conclusion: Our findings suggest that DVT has the potential to be a useful research and diagnostic tool in the assessment of bone quality. However, it is important to determine the level of kVp with the best diagnostic capacity by considering the patient dose.

Benzer Tezler

  1. Akut göğüs ağrısında tanıda düşük doz kontrast madde ve radyasyon kullanarak ikili ve üçlü dışlama bilgisayarlı tomografi anjiografisi kullanımı

    The use of dual and triple rule out computerized tomography angiography by using diagnostic low-dose contrast material and radiation in acute chest pain

    AHMET KEREM İMREK

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2022

    Radyoloji ve Nükleer TıpBolu Abant İzzet Baysal Üniversitesi

    Radyoloji Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ MUSTAFA HIZAL

  2. Postoperatif radyoterapi uygulanan prostat kanserli olgularda planlama ile tedavi sırasındaki mesane ve rektum dozlarının doz volüm histogramlarına göre karşılaştırılması

    Rectum and bladder dose variations during the course of image guided radiotherapy for postoperative prostate cancer

    MUSTAFA AKIN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2013

    Onkolojiİstanbul Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    PROF. DR. FAZİLET ÖNER DİNÇBAŞ

  3. Pulmoner tromboembolizmde düşük kilovolt pulmaner BT anjiografi

    Low-kilovoltage pulmonary CT angiography in pulmonary thromboembolism

    MURAT SERHAT AYGÜN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2008

    Radyoloji ve Nükleer TıpAnkara Üniversitesi

    Radyodiagnostik Ana Bilim Dalı

    DOÇ. DR. ÇETİN ATASOY

  4. Paranazal sinüs bilgisayarlı tomografi tetkiklerinde yüksek pitch kullanımının radyasyon dozu üzerine etkisi

    The effects of high pitch on radiation dose of paranasal sinus computed tomography

    TİJEN CANKURTARAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2014

    Radyoloji ve Nükleer TıpHacettepe Üniversitesi

    Radyoloji Ana Bilim Dalı

    PROF. DR. ERHAN AKPINAR

  5. Konik huzmeli bilgisayarlı tomografi görüntülerinin tedavi planlama amaçlı kullanımı

    Treatment planning purposes use of cone-beam computed tomography images

    ÖZLEM YAŞAR TOYKAN ÇİFTLİKLİ

    Yüksek Lisans

    Türkçe

    Türkçe

    2016

    Radyoloji ve Nükleer TıpAkdeniz Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    PROF. DR. MELEK NUR YAVUZ