Geri Dön

Sayısal çıkarmalı anjiyografide görüntü artifaktlarının polinom yaklaşımlı geometrik dönüşümle düzeltilmesi

Polynomial based geometric correction of artifacts in digital subtraction angiography

  1. Tez No: 782789
  2. Yazar: KALİ GÜRKAHRAMAN
  3. Danışmanlar: YRD. DOÇ. DR. AHMET SEMİH BİNGÖL
  4. Tez Türü: Yüksek Lisans
  5. Konular: Elektrik ve Elektronik Mühendisliği, Electrical and Electronics Engineering
  6. Anahtar Kelimeler: sayısal çıkarmalı anjiyografi, DSA, artifakt, maske, canlı, geometrik görüntü düzeltme, tıbbi görüntü işleme, görüntü benzerlik ölçütleri, digital subtraction angiography, DSA, artifact, mask, live, geometric image correction, medical image processing, image similarity measure
  7. Yıl: 2001
  8. Dil: Türkçe
  9. Üniversite: Hacettepe Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Elektrik-Elektronik Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 69

Özet

Bu çalışmada, sayısal çıkarmalı anjiyografide (Digital Subtraction Angiography, DSA) hasta veya organ hareketleri ve piksellerin gri seviye farklılıklarından dolayı oluşan ve artifakt olarak adlandırılan görüntü bozukluklarının giderilmesi konusu işlenmiştir. DSA insan kan damarlarının görüntülenmesini maske (mask) ve canlı (live) görüntülerin birbirinden çıkarılmasıyla gerçekleştirmektedir. Maske ve canlı sırasıyla kontrast maddenin damar yoluyla hastaya enjeksiyonu öncesi ve sonrası çekilen aynı anatomik bölgenin görüntüleridir. Bu iki görüntünün birbirinden çıkarılmasıyla damar dışındaki anatomik yapı yok edilerek damarların daha iyi görüntülenmesi sağlanmaktadır. Artifaktların giderilmesi için maske ile canlı görüntü arasında, benzerlik ölçüt algoritmalarından faydalanarak, birbiriyle örtüşen kontrol noktalarının kayma vektörleri belirlenerek düzeltme işlemi yapılmaktadır. Bu çalışmada, çeşitli benzerlik ölçüt algoritmaları karşılaştırılmış, farklı DSA görüntüleri üzerinde değişik pencere boyutlarıyla denenmiş ve buna ilişkin sonuçlar değerlendirilmiştir. En iyi performansa sahip olduğu belirlenen algoritmalar görüntü kaymalarının geometrik düzeltilmesi işleminde kullanılmıştır. Geometrik düzeltme işlemi, derecesi değiştirilebilen bir polinom eşitliği kullanılarak yapılmıştır. Polinomun katsayıları bir doğrusal matris eşitliğin çözümüyle hesaplanmıştır. Lineer matris eşitliğinin çözümünü sağlamak için, benzerlik ölçüt algoritmaları ile belirlenmiş olan ve kayma vektörünü tanımlayan piksellerin koordinat değerleri kullanılmıştır. Maske görüntüsünün hasta ve organ hareketlerinden etkilenen görüntü olduğu farzedilmiş ve düzeltme işlemi bu görüntü üzerinde gerçekleştirilmiştir. Maske görüntüye ait tüm piksellerin koordinat (satır ve sütun) değerleri polinom eşitliğine girdi olarak verilmiş, görüntünün yeniden oluşturulmasında kullanılacak düzeltilmiş koordinat değerleri çıktı olarak elde edilmiştir. Sonuçta, kayma problemi olan çeşitli DSA görüntülerinde benzerlik ölçüt algoritmalarıyla kontrol noktalarının kayma vektörleri çıkarılmış ve polinom yaklaşımı ile geometrik düzeltme işlemi gerçekleştirilmiştir.

Özet (Çeviri)

In this study, we deal with correction of artifacts caused by patient motion and gray level variations of pixels in Digital Subtraction Angiography (DSA). In DSA the human blood vessels can be visualized by subtracting a live image from a mask image. The mask and the live images are x-ray images of the same anatomic body of interest taken before and after the injection of contrast medium, respectively. In the resulting subtracted image visualization of blood vessels is enhanced by eliminating the background anatomical structure. Similarity measure algorithms are used to determine a motion vector for each control point between the mask and live image pair. In this study and experimental comparison of similarity measure algorithms is made on different DSA image pairs to decide on the most successful ones to use them in determining the control points. Geometric correction of motion artifacts is implemented by a polynomial function with variable order whose coefficients are calculated by solving a linear matrix equation using the control points determined by the similarity measure algorithms. The coordinates (row and column values) of all the pixels of mask image, which is considered as distorted image, are input to the polynomial function and the corresponding original (corrected or undistorted) coordinates are obtained as output. Original image is then constructed by using the output coordinate values. The thesis concludes with polynomial based geometric correction of some DSA image pairs using motion vectors determined by similarity measure algorithms.

Benzer Tezler

  1. Sayısal çıkarma anjiografisinde radyasyon dozu-görüntü kalitesi optimizasyonu

    Radiation dose-image quality optimisation of digital subtraction angiography

    ONUR EDE

    Yüksek Lisans

    Türkçe

    Türkçe

    2007

    Fizik ve Fizik MühendisliğiAnkara Üniversitesi

    Fizik Mühendisliği Ana Bilim Dalı

    PROF.DR. DOĞAN BOR

  2. Investigation of effectiveness of flow diverter stents and detecting stagnation region formation in aneurysm sac using lagrangian coherent structure analysis

    Lagrangıan tutarlı yapı analizleri kullanılarak anevrizma kesesi içerisindeki durağan bölge oluşumlarının tespiti ve akış saptırıcı stentlerin etkinliklerinin incelenmesi

    ONUR MUTLU

    Yüksek Lisans

    İngilizce

    İngilizce

    2020

    Makine MühendisliğiYeditepe Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    DOÇ. DR. ALİ BAHADIR OLCAY

  3. Investigation of hemorheologic effects of flow diverting stent implantation in cerebral aneurysms

    Beyin anevrizmalarına yerleştirilen akım değiştirici stentin hemoreolojik etkilerinin incelenmesi

    OSMAN ERGİN

    Yüksek Lisans

    İngilizce

    İngilizce

    2023

    Makine MühendisliğiYeditepe Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    DOÇ. DR. ALİ BAHADIR OLCAY

    PROF. DR. İSMAİL ORAN

  4. Real-time dual-energy x-ray digital subtraction imaging system

    Başlık çevirisi yok

    HALDUN ÖZDEMİR

    Yüksek Lisans

    İngilizce

    İngilizce

    1990

    Elektrik ve Elektronik MühendisliğiOrta Doğu Teknik Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    DOÇ.DR. HAYRETTİN KÖYMEN

  5. Designing a phantom for performance evaluation of (DSA) units

    Dijital çıkartmalı anjiyo cihazlarının performans değerlendirilmesi için fantom tasarımı

    PELİN DOĞRUÖZ

    Yüksek Lisans

    İngilizce

    İngilizce

    2004

    Tıbbi BiyolojiBoğaziçi Üniversitesi

    Metalurji ve Malzeme Mühendisliği Ana Bilim Dalı

    PROF. DR. YEKTA ÜLGER