Sayısal çıkarma anjiografisinde radyasyon dozu-görüntü kalitesi optimizasyonu

Radiation dose-image quality optimisation of digital subtraction angiography

  1. Tez No: 196901
  2. Yazar: ONUR EDE
  3. Danışmanlar: PROF.DR. DOĞAN BOR
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Radyoloji ve Nükleer Tıp, Physics and Physics Engineering, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2007
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Fizik Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 152

Özet

ÖZETYüksek Lisans TeziSAYISAL ÇIKARMA ANJİYGRAFİSİNDE RADYASYON DOZU-GÖRÜNTÜKALİTESİ OPTİMİZASYONUOnur EDEAnkara ÜniversitesiFen Bilimleri EnstitüsüFizik Mühendisliği Anabilim DalıDanışman : Prof. Dr. Doğan BORSayısal çıkarma anjiyografi sistemlerinde hasta dozları düşük tutulurken en iyi görüntükalitesinin nasıl elde edileceği incelenmiştir. Yapılan ölçümler farklı ışınlama modlarında(floroskopik, DA, DSA), farklı geometrik büyütme faktörlerinde ( BF = 1,66 ve BF = 1,4 ),farklı kalınlıktaki saçıcı fantomlar ( göğüs, karın, baş ve ekstremite eş değeri fantomlar ) içintekrarlanarak karşılaştırılmıştır. Ölçüm sonuçları görsel ( test objeleri yardımıyla ) vematematiksel olarak ( MTF, NPS ) iki farklı şekilde değerlendirilmiştir. Görsel olarakdeğerlendirmede yüksek kontrast ayırma gücü, alçak kontrast ayırma gücü ve kontrast ayrıntıtestleri yapılmıştır. Sistemin en iyi yüksek kontrast ayırma gücü DA modunda micro odaktave FOV 14'de 2,2 çç/mm olarak elde edilmiştir. Alçak kontrast ayırma gücü testinde en iyisonuç DSA modunda, micro odakta, FOV 14 için 0,86 % kontrast olarak bulunmuştur.Kontrast ayrıntı testinin sonucunda tüm ışınlama modlarında birbirine yakın sonuçlargözlenmiştir. Görüntü kalitesinin nümerik olarak değerlendirilmesinde, MTF için küçük açıile ( ~ 50 ) açılandırılmış kenar dağılım yöntemi kullanılmıştır. Elde edilen görüntülerden,Imatest 2.0.7 programı kullanılarak MTF değerleri bulunmuştur. NPS değerleri bulunurken,x-ışını anjiyografi sisteminden elde edilen 1024x1024 piksel boyutlarındaki homojen birgörüntüden 10 tane 128x128 piksel boyutlarında görüntüler alınıp metin dosyası olarakkaydedildi. Kaydedilen görüntülerin MATLAB 7.0.1 matematik programı yardımıyla NPSdeğerleri bulundu ve bunların ortalaması alınarak sistem için NPS değeri hesaplanmıştır.2007, 152 sayfaAnahtar Kelimeler : Radyasyon dozu, görüntü kalitesi, sayısal çıkarma, anjiografi

Özet (Çeviri)

ABSTRACTMaster ThesisRADIATION DOSE-IMAGE QUALITY OPTIMISATIONOF DIGITAL SUBSTRACTION ANGIOGRAPHYOnur EDEAnkara UniversityGraduate School of Natural and Applied SciencesDepartment of Engineering PhysicsSupervisor: Prof. Dr. Doğan BORThe optimum image quality was determined related to patient and image intensifier inputdoses. Image quality measurements were carried out for different exposure modes, field ofview and different scatter phantom thicknesses and compared to each other. Measurementswere determined as visibly and mathematically. High contrast spatial resolution, klow contrastspatial resolution and contrast detail tests were carried as visible measurements. The highesthigh contrast spatial resolution was achieved at DA mode with micro focus and FOV 14 as2.2 lp/mm. The best low contrast spatial resolution was achieved at DSA mode with microfocus and FOV as 0.86%. Similar results were obtained for contrast detail test. Numericalspatial resolution measurements was evaluated with small angle edge method . Imatest 2.0.7computer programme was used for these evaluations and found MTF values. While the NPSdetermination a Picture of 1024x1024 pixel size was selected from x-ray angiography. 10images with 128x128 matrix sizes were used for NPS determination. These images convertedto text file and processed at MATLAB 7.0.1 and the mean NPS of 10 images calculated assystem NPS.2007, 152 pagesKey Words : Radiation dose, image quality, digital substraction, angiography

Benzer Tezler

  1. Anevrizma kesesinde ve parent arterde peroperatif basınç ölçümlerinin kanamış ve kanamamış hastalarda karşılaştırılması

    The comparison of perioperative pressure measurements in intra-aneurysmal and parent artery in ruptured and unruptured aneuryms

    SEDA KANBAĞLI

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2013

    Radyoloji ve Nükleer TıpDokuz Eylül Üniversitesi

    Radyoloji Ana Bilim Dalı

    PROF. DR. SÜLEYMAN MEN

  2. Karotis Arterin Değerlendirilmesinde 128 Kesit BT Anjiografi ve Teknik Optimizasyonu

    128 Slice CT Angiography in The Evaluation Of Carotid Artery And Technical Optimization

    ERGÜN CEYLAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2010

    Radyoloji ve Nükleer TıpSüleyman Demirel Üniversitesi

    Radyoloji Ana Bilim Dalı

    YRD. DOÇ. DR. MUSTAFA KAYAN

  3. Sayısal kenar çıkarma ve yapay sinir ağları yardımıyla araç tanıma

    Vehicle detection by numerical edge detection and artificial neural networks

    MEHMET ALİ SOYTÜRK

    Yüksek Lisans

    Türkçe

    Türkçe

    2005

    Elektrik ve Elektronik MühendisliğiErciyes Üniversitesi

    Elektronik Mühendisliği Ana Bilim Dalı

    DOÇ. DR. MEHMET EMİN YÜKSEL

  4. İki boyutlu sayısal filtreler

    Two dimensional digital filters

    AYTEN GEÇMEZ

    Yüksek Lisans

    Türkçe

    Türkçe

    2014

    Elektrik ve Elektronik MühendisliğiFırat Üniversitesi

    Devreler ve Sistemler Ana Bilim Dalı

    DOÇ. DR. MELİH CEVDET İNCE

  5. Anasınıfı öğrencilerinde, sayı kavramını geliştirmeye yönelik görsel araçlar ve anasınıfı öğrencileri için sayı kavramı alıştırma kitabı örneği

    Visual materials for developing number concept of early childhood students and a sample of number concept exercise book for early childhood education

    BANU DAVUN

    Yüksek Lisans

    Türkçe

    Türkçe

    1997

    Eğitim ve ÖğretimGazi Üniversitesi

    Resim Ana Sanat Dalı

    PROF. DR. YÜKSEL BİNGÖL