Geri Dön

Memenin elektron huzmesi ile ek doz ışınlamasında doz optimizasyonu

Dose optimisation of boost irradiation using electron beam in breast cancer

  1. Tez No: 79836
  2. Yazar: MURAT OKUTAN
  3. Danışmanlar: DOÇ. DR. GÖNÜL KEMİKLER
  4. Tez Türü: Yüksek Lisans
  5. Konular: Biyofizik, Radyoloji ve Nükleer Tıp, Biophysics, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 1999
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Tıbbi Radyofizik Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 43

Özet

Amaç: Çalışmamızda, elektron boost alanının, klinik veriler + cerrahi insizyon veya klinik veriler + cerrahi insizyon ve küplere göre saptandığı iki tedavi planlaması doz optimizasyonu yönünden karşılaştırmıştır. Materyal ve Metot: Değerlendirme, cerrahi girişim sırasında tümör yatağının sınırları küplerle işaretlenmiş 10 hastada yapılmıştır. Başlangıçta bu hastalarda tedavi alanı ve tedavi derinliği, cerrahi insizyon hattı ve cerrahi öncesi verilerle tespit edilmiştir. Bilgisayarlı tomografi filmleri çekilerek, tümör yatağı derinliği bilinmediği için merkezi kesitte % 85'lik referans izodozun göğüs duvarı iç yüzünden geçmesi referans alındı. İkinci planlamada ise cerrahi küpler dikkate alınarak % 85 referans izodozun her kesitteki klipi 1 cm. marj ile kapsaması amaçlanarak enerji, alan boyutu, gantry açısı, kolimatör açısı ve alan merkezi gibi parametrelerin değişikliği incelendi. Her iki boost tedavi alanı belirleme yöntemi, referans izodoz ve target volüm ilişkisi gözönüne alınarak boost alanının akciğer dozlarına katkısını değerlendirmek üzere doz-volüm yönünden analizi yapıldı. Bulgular: Küpler dikkate alındıktan sonra değerlendirme yapıldığı zaman 10 hastanın 5'inde (% 50) enerji, 9'unda (% 90) alan boyutu, 5'inde (% 50) gantry açısı, 4'ünde (% 40) kolimatör açısı ve 5'inde (% 50) de alan merkezinde değişiklik yapılmıştır. Skar ve klinik bilgilere dayalı yapılan ek doz planlamasında, homojenite düzeltmesi yapılmamış hastalarda target dozunun % 75, 50 ve 25'ini alan akciğer volümü % 0-2, % 0-4, % 0-9 arasında değişirken, küpler gözönüne alındığı zaman ve homojenite düzeltmesi yapıldığı zaman bu volümler % 0-5, % 2-1 1, % 6-32 olarak belirlenmiştir. 32Sonuç: Bu veriler ışığında lokal başarısızlığı azaltmak ve target volümde optimum doz dağılımı elde etmek için cerrahi küplerin kullanımını önermekteyiz.

Özet (Çeviri)

The aim: The study has been designed to compare the difference between two types of guides for the boost treatment planning methods which are clinical parameters plus surgical scars, and clinical parameters plus surgical scars plus clips placed in the tumor bed. Methods: Ten patients who had surgical clips placed in the tumor bed at the time of tumor excision were evaluated. At first, treatment field and treatment depth of this patients were defined according to incision scars and clinical parameters of the patients before surgery. In the first types of treatment planning since the tumor bed depth was can not be determined, CT scan were done and inner surface of the thorasic wall were covered by 85% reference isodose on the central slice. In the second one, ifs aimed that all clips within 1 cm in 85% reference dose of each slice encompassed in the treatment plan. The changes in field, energy, gantry angle, collimator angle, and field center were evaluated. Each boost treatment planning method were analyzed in order to evaluate the contribution of boost field to the lung doses, in consideration of reference isodose and target volume. Results: It has been shown that in 5 out of 10 patients (50%) the energy, in 9 patients (90%) the fields, in 5 patients (50%) the gantry angles, in 4 patients (40%) the collimator angles, and in 5 patients (50%) the field centers should have been corrected when the clips were taken in consideration. In the patients in whom the boost dose planning were done according to the incision scar and clinical findings and the homogeneity correction was not done dose volume that took the 75%, 50%, and 25% of the target dose were 0-2 %, 0-4 %, 0-9 % respectively. But if the clips were considered and the homogeneity was corrected, the volume was 0-5 %, 2-1 1 %, 6-32 % respectively. 34Conclusion: This study demonstrates that surgical clips and CT scan usage are important to correct the lung tissue volume doses and to do appropriate boost treatment planning.

Benzer Tezler

  1. Memenin paget hastalığında patolojik anatomik ve ultrastrüktürel inceleme

    Başlık çevirisi yok

    BEKİR ARZUMAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    Onkolojiİstanbul Üniversitesi

    Patoloji Ana Bilim Dalı

  2. Sol meme radyoterapisinde mammaria interna alanın ışınlamasında geniş tanjansiyel-elektron kombinasyon tekniği ile foton-elektron kombinasyon tekniğinin karşılaştırılması ve kardiak dozların analizi

    The comparision of the wide tangential - electron combination technique with photon - electron combination technique on the radiation of mammaria interna field during left breast radiotherapy and the analysis of cardiac doses

    FATMA BETÜL ALTAŞ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2010

    OnkolojiDokuz Eylül Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    PROF. DR. FEVZİ HİLMİ ALANYALI

  3. Piezo meme üretimi dış yüzey taşlama prosesinde sıkma sistemi hatasının sistematik biçimde araştırılması ve takım maliyetinin düşürülmesi

    Systematic investigation of tool failures in outer grinding process at piezo nozzle production and reduce tool cost

    SEHNAZ UYSALTÜRK

    Yüksek Lisans

    Türkçe

    Türkçe

    2013

    Makine MühendisliğiUludağ Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. AGAH UĞUZ

  4. Mammaria interna alanının hedef hacme dahil olduğu meme kanseri radyoterapisinde farklı tekniklerin karşılaştırılması

    Comparison of different techniques in breast cancer radiotherapy covering internal mammary region in the target volume

    MEHMET HAKAN DOĞAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2004

    Radyoloji ve Nükleer TıpHacettepe Üniversitesi

    Radyasyon Fiziği Uygulamaları Ana Bilim Dalı

    PROF. DR. FARUK ZORLU

  5. Analysis and field observation of diesel fuel injector nozzle reliability

    Dizel enjektör memesinin saha güvenilirliğinin incelenmesi

    İBRAHİM CİVANOĞLU

    Yüksek Lisans

    İngilizce

    İngilizce

    2017

    Makine Mühendisliğiİstanbul Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. OSMAN AKIN KUTLAR