Koklear implantlarda yaşa ve cinsiyete göre impedans değerinin değişimi

Change of impedance value in cochlear implants according to age and gender

  1. Tez No: 802112
  2. Yazar: DEVRAN SÖKMEN
  3. Danışmanlar: DR. ÖĞR. ÜYESİ FERHAT KORKMAZ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Kulak Burun ve Boğaz, Otorhinolaryngology (Ear-Nose-Throat)
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2023
  8. Dil: Türkçe
  9. Üniversite: Kapadokya Üniversitesi
  10. Enstitü: Lisansüstü Eğitim, Öğretim ve Araştırma Enstitüsü
  11. Ana Bilim Dalı: Odyoloji Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 54

Özet

İşitme cihazlarından fayda göremeyen ileri işitme kayıplı bireylerde işitmenin sağlanması için kullanılan yöntemlerden birisi koklear implant uygulamasıdır. Koklear implant ilk implante edildiğinde elektrot impedansları genel olarak düşüktür ve bu değer elektrot ped ve yüzey alanından, koklear özelliklerde ya da elektrot konumundan etkilenir. Koklear implantta impedans ölçümünün temel amacı yerleştirilen elektrodların doku veya sinir ile temas halinde olup olmadığını anlamamızı sağlamaktır. Çalışmamızda koklear implantlarda yaşa ve cinsiyete göre impedans değişimi değerinin incelenmesi amaçlandı. Bu amaç doğrultusunda çalışmaya 40 adet koklear implant operasyonu geçirmiş hasta dahil edildi. Koklear implant operasyonu geçiren bireylerden operasyon esnasında ve operasyon sonrasında ölçümler yapılarak impedans değerleri belirlenmiştir. Ayrıca katılımcıların demografik özelliklerini belirlemek için de veri kayıt formu formu kullanıldı. Çalışma sonucunda ameliyat esnasındaki ve sonrasındaki ilk ölçülen impedans değerlerinde anlamlı bir fark olmadığı görüldü (p>0.05). Ameliyattan sonraki ikinci ölçümlerde 6., 11., 16. ve 22. elektrotlarda ölçülen impedans değerlerinin ameliyat esnasında 6., 11., 16. ve 22. elektrotlarda ölçülen impedans değerine göre anlamlı şekilde düşük olduğu görüldü. Ameliyattan sonraki üçüncü ölçümlerde 1., 6., 11., 16. ve 22. elektrotlarda ölçülen impedans değerlerinin ameliyat esnasında 1., 6., 11., 16. ve 22. elektrotlarda ölçülen impedans değerine göre anlamlı şekilde düşük olduğu görüldü. Cinsiyete göre ameliyat esnasındaki ve ameliyat sonrasındaki impedans değerlerinde anlamlı bir farklılık saptanmadı. Yaş ile ameliyattan sonraki ikinci ölçümde 1. Elektrotta ölçülen impedans değeri arasında pozitif yönlü ve zayıf düzeyde ilişki saptanmıştır.

Özet (Çeviri)

Cochlear implant application is one of the methods used to provide hearing in individuals with severe hearing loss who cannot benefit from hearing aids. When a cochlear implant is first implanted, electrode impedances are generally low and are affected by the electrode pad and surface area, cochlear properties, or electrode location. The main purpose of impedance measurement in a cochlear implant is to enable us to understand whether the placed electrodes are in contact with tissue or nerve. In our study, it was aimed to examine the value of impedance change in cochlear implants according to age and gender. For this purpose, 40 patients who had undergone cochlear implant operations were included in the study. Impedance values were determined from individuals who underwent cochlear implant operation by making measurements during and after the operation. In addition, a data registration form was used to determine the demographic characteristics of the participants. As a result of the study, it was observed that there was no significant difference in the first measured impedance values during and after the operation (p>0.05). In the second measurements after the surgery, it was observed that the impedance values measured at the 6th, 11th, 16th and 22nd electrodes were significantly lower than the impedance values measured at the 6th, 11th, 16th and 22nd electrodes during the operation. In the third measurements after the surgery, it was observed that the impedance values measured at the 1st, 6th, 11th, 16th and 22nd electrodes were significantly lower than the impedance values measured at the 1st, 6th, 11th, 16th and 22nd electrodes during the surgery. There was no significant difference in the intraoperative and postoperative impedance values according to gender. A positive and weak correlation was found between age and the impedance value measured at the 1st electrode in the second measurement after the operation.

Benzer Tezler

  1. İşitme engelliler için homojen alan dağılımlı gişe tipi ses frekansı indüksiyon döngü sistemi tasarımı

    Uniform field distribution audio frequency counter induction loop design for hearing impaired

    MELTEM LORDOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    2022

    Elektrik ve Elektronik Mühendisliğiİstanbul Teknik Üniversitesi

    Elektrik Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ DENİZ YILDIRIM

    DOÇ. DR. SERHAT İKİZOĞLU

  2. Koklear implant kullanıcılarında trifazik uyarım ve spektral - temporal rezolüsyonun değerlendirilmesi

    Triphasic pulse stimulation and evaluation of the spectral - temporal resolution in cochlear implant users

    MÜSLÜME KÜBRA KOÇ

    Yüksek Lisans

    Türkçe

    Türkçe

    2023

    Kulak Burun ve BoğazHacettepe Üniversitesi

    Odyoloji Ana Bilim Dalı

    DOÇ. DR. BETÜL ÇİÇEK ÇINAR

  3. Koklear implantlarda impedans, T ve C değerlerinin yıllara göre değişimi

    Changes of impedance, threshold and comfortable levels upon years in cochlear implants

    SERDAR SİPAHİ

    Yüksek Lisans

    Türkçe

    Türkçe

    2012

    Kulak Burun ve BoğazBaşkent Üniversitesi

    Odyoloji ve Konuşma Bozuklukları Ana Bilim Dalı

    PROF. DR. ERDİNÇ AYDIN

  4. Çok ileri derecede sensorinöral işitme kaybı nedeniyle koklear implantasyon yapılmış olan hastaların preoperatif ve postoperatif değerlendirilmesi ve koklear implantasyon başarı oranlarımız

    Pre-operative and post-operative results of patients treated with cohlear implantation for very severe sensoryneural hearing loss

    HÜSEYİN IŞILDAK

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2011

    Kulak Burun ve Boğazİstanbul Üniversitesi

    Kulak Burun Boğaz Ana Bilim Dalı

    PROF. HÜSNÜ ÖZEK

  5. Wireless data transmission for medical implants with fully digital non-coherent detection

    Tıbbi implantlar için tamamen dijital tutarlı olmayan tespitli kablosuz veri aktarımı

    MERT DOĞAN

    Yüksek Lisans

    İngilizce

    İngilizce

    2021

    Elektrik ve Elektronik MühendisliğiOrta Doğu Teknik Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    PROF. DR. HALUK KÜLAH