Tıbbi cihaza bağlı basınç yarası risk değerlendirme ölçeğinin geliştirilmesi
Developing a medical device-related pressure wound risk assessment scale
- Tez No: 813625
- Danışmanlar: PROF. DR. GÜLAY İPEK ÇOBAN
- Tez Türü: Doktora
- Konular: Hemşirelik, Nursing
- Anahtar Kelimeler: Basınç yarası, hemşirelik, ölçek, risk değerlendirme ölçeği, tıbbi cihaz, Hemşireler, Hemşirelik araştırmaları, Risk değerlendirmesi, Tıbbi cihazlar, Ölçekler, Medical device, nursing, pressure ınjury, risk assessment, scale, Pressure sore, Nurses, Nursing research, Risk assesment, Medical devices, Scales
- Yıl: 2023
- Dil: Türkçe
- Üniversite: Atatürk Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Hemşirelik Esasları Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç: Araştırma tıbbi cihaz uygulanan hastaların tıbbi cihaza bağlı basınç yarası riskini değerlendirmek için geçerli ve güvenilir bir ölçme aracı geliştirmek amacıyla yapılmıştır. Materyal ve Metot: Metodolojik olarak gerçekleştirilen bu araştırma tıbbi cihaza bağlı olan hastaların bakım ve tedavisinin yapıldığı; yoğun bakım üniteleri, palyatif bakım kliniği, evde bakım birimi, cerrahi ve dahili kliniklerde gerçekleştirilmiştir. Tıbbi Cihaza Bağlı Basınç Yarası Risk Değerlendirme Ölçeğinin geçerlik-güvenirlik çalışması 200 tıbbi cihaza bağlı hasta ile yapılmıştır. Araştırmanın verilerinin toplanmasında,“Hasta Tanıtıcı Özellikler Formu”, taslak“Tıbbi Cihaza Bağlı Basınç Yarası Risk Değerlendirme Ölçeği (TCBYRÖ)”ve“Braden Risk Değerlendirme Ölçeği”kullanılmıştır. Veriler; güvenirlik ve geçerlik analizleri kapsamında, Açıklayıcı ve Doğrulayıcı Faktör Analizi, Cronbach's Alpha, Pearson Momentler Çarpımı Korelasyon analizi ile değerlendirilmiştir. Ayrıca, veri değerlendirilmelerinde yüzdelik, ortalama, bağımsız gruplarda t testi ve ileri analizler de kullanılmıştır. Bulgular: Tıbbi Cihaza Bağlı Basınç Yarası Risk Değerlendirme Ölçeğinin Cronbach's alpha güvenilirlik değeri 0,73 olarak belirlenmiştir. Kaiser-Meyer Olkin değeri 0,72 ve Barlett test x2=553,236 (p<0.05)'dır. Bununla birlikte ölçeğin örneklem büyüklüğünün faktör analizi için uygun olduğu saptanmıştır. Ölçek maddeleri 2 faktör altında toplanarak, açıklayıcı katsayısı %47,063 olarak bulunmuştur. TCBYRÖ'nün 2 faktörlü yapısını oluşturan bileşenler incelenerek uygun olacak şekilde 1. Faktör“Hastanın Genel Durumu”ve 2. Faktör“Tıbbi Cihazın Temas Bölgesine Etki Durumu”olarak isimlendirilmiştir. Doğrulayıcı faktör analizinde kullanılmakta olan uyum indeksi x2/sd: 2,091 şeklinde hesaplanmıştır. Son haliyle 8 madde olarak belirlenen taslak ölçeğin sorun teşkil eden bir maddesinin olmadığı tespit edilmiştir. Sonuç: Yapılan analizler sonucunda 8 madde ve 2 faktör olarak belirlenen TCBYRÖ'nün güvenilir ve geçerli bir ölçme aracı olduğu saptanmıştır. Ölçekten alınabilecek en yüksek puan 27 ve en düşük 8 puan olarak belirlenmiştir. Ölçeğin toplam puanında 8-11 puan yüksek risk düzeyini, 13-20 puan orta risk düzeyini, 22-27 puan düşük risk düzeyini ifade ettiği tespit edilmiştir. Geliştirilen bu ölçek, tıbbi cihaz uygulanan hastaların TCBY riskinin değerlendirilmesinde kullanılabilir.
Özet (Çeviri)
Aim: The study was conducted to develop a valid and reliable measurement tool to evaluate the risk of pressure ınjury happening because of medical devices in patients who use medical devices. Materials and Methods: This methodological study was conducted in intensive care units, palliative care clinics, home care units, and surgical and internal diseases clinics where care and treatment of patients using medical devices were provided. The validity-reliability study of the Medical Device-Induced Pressure Injury Risk Assessment Scale was conducted with 200 patients who were using medical devices. The“Patients' Descriptive Characteristics Form”,“Medical Device-Induced Pressure Injury Risk Assessment Scale draft (MDPIRS)”, and“Braden Risk Assessment Scale”were used to collect the data for the study. The data were analyzed with the Exploratory and Confirmatory Factor Analysis, Cronbach's Alpha, and Pearson Product Moments Correlation analysis within the scope of reliability and validity analyses. Also, percentages, mean values, independent groups t-tests, and further analyzes were used in the evaluation of the study data. Results: The Cronbach's Alpha Reliability Value of the Medical Device-Induced Pressure Ingury Risk Assessment Scale draft was determined as 0.73. The Kaiser-Meyer Olkin Value was 0.72, and Bartlett's Test was found to be x2=553.236 (p<0.05). The sample size of the scale was found to be suitable for factor analysis. The scale items were gathered under 2 factors, and the explanatory coefficient was found to be %47,063. The components that constituted the 2-factor structure of the MDPIRS were examined and named“General Condition of the Patient”(Factor 1) and“Impact of the Medical Device on the Contact Area”(Factor 2). The Fit Index used in the Confirmatory Factor Analysis was calculated to be x2/sd: 2.091. It was determined that the draft scale, which had a 8- item structure in its final form, did not have any problematic items. Conclusion: As a result of the analyses, it was found that determined as 8 items and 2 factors, was a reliable and valid measurement tool. The highest score that can be obtained from the scale is determined as 27 and the lowest score is 8. In the total score of the scale, it was determined that 8-11 points expressed a high-risk level, 13-20 points expressed a medium-risk level, and 22-27 points expressed a low-risk level. This developed scale can be used to evaluate the risk of MDPIRS in patients undergoing medical devices.
Benzer Tezler
- BCS Sınıf II bir antidiyabetik ve BCS Sınıf IV bir diüretik için nanokristal bazlı formülasyonların geliştirilmesi ve karakterizasyonu
Development and characterization of nanocrystal-based formulations for a BCS class II antidiabetic and a BCS class IV diuretic
FATIMA KHALIFA M. A. AL-SULAITI
- Ameliyat öncesi hastaların ameliyata ilişkin duyguları, düşünceleri ve bilgi istekleri
The Pre-operative patiensts feelings throughts and information requirements concerning their surgical operations
KADRİYE BULDUKOĞLU
- Sivas ili C.Ü. hastanesinde yatmakta olan hastaların servislerine kabul edilişlerindeki uygulamalarla bu uygulamalara ilişkin duygu ve beklentilerinin saptanması
Determination of the formalities in admitting the patients hospitalized at the Cumhuriyet University of Sivas to the services and their feelings and expeetations relating to these formalities
FADİME KESKİN