Geri Dön

Farklı materyal ve tekniklerle üretilen implant abutment materyallerinin afm ve sem ile yüzey pürüzlülüklerinin karşılaştırılması ve mikrobiyolojik tutulumlarının incelenmesi

Surface roughness comparison of implant abutments produced with different materials and techniques by afm and sem and investigation of microbiological retention

  1. Tez No: 818835
  2. Yazar: SERTER MERT SELAMET
  3. Danışmanlar: PROF. DR. TOMURCUK ÖVÜL KÜMBÜLOĞLU
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2023
  8. Dil: Türkçe
  9. Üniversite: Ege Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 104

Özet

Amaç: Bu çalışmada farklı materyal ve metodlarla üretilen abutmentların Atomik Kuvvet Mikroskobu (AFM) ve Taramalı Elektron Mikroskobu (SEM) analizleri sonucunda yüzey pürüzlülüklerinde ve mikrobiyolojik analizlerinde Streptococcus Mutans ve Candida Albicans tutulumları arasında fark olup olmadığının araştırılması amaçlanmıştır. Gereç ve Yöntem: Çalışmada kullanılan materyal/teknik kombinasyonları olarak; Döküm yöntemiyle üretilmiş Metal Alaşımı (Cr-Co), CAD-CAM Milling yöntemiyle üretilmiş Metal Alaşımı (Cr-Co), CAD-CAM Milling yöntemiyle üretilmiş Titanyum (Grade 5), CAD-CAM Milling yöntemiyle üretilmiş Zirkonya, CAD-CAM Milling yöntemiyle üretilmiş ve anodizasyon metoduyla renklendirilmiş Titanyum, Lazer-Sinterizasyon yöntemiyle üretilmiş Metal Alaşımı (Cr-Co) ve kontrol grubu olarak fabrikadan temin edilen stock abutmentlar (Grade 5) kullanılmıştır. Yapılan güç analizine göre her bir grup başına 7 adet olmak üzere toplam 49 adet örnek 5 mm x 2 mm boyutlarında disk şeklinde hazırlanmıştır. Her bir gruba üretim sonrası standardize bir şekilde literatürde tarif edilen metodlarla tesviye ve cila işlemleri uygulanmıştır. Hazırlanan her bir örnek öncelikle AFM ve sonrasında da SEM kullanılarak incelenmiş ve elde edilen yüzey özelliklerine ait değerler kaydedilmiştir. Elde edilen bu bulgular istatistiksel olarak Kruskal-Wallis testi ve Non-parametrik testler ile değerlendirilmiştir. Ardından tüm gruplara grup başına 3 adet örnek olmak üzere S. Mutans ve C. Albicans kullanılarak 8 saat ve 24 saat olmak üzere ekim yapılarak geçen süre sonundaki toplam mikroorganizma miktarı sayılmıştır. Elde edilen veriler kaydedilmiş ve bulgular istatistiksel olarak ANOVA ve Tukey HSD testleri ile değerlendirilmiştir. Bulgular: Yüzey pürüzlülüğü parametreleri incelendiği zaman gruplar arasında Ra, Rq ve Rmax değerleri için istatistiksel olarak anlamlı fark bulunmuştur (p

Özet (Çeviri)

Surface Roughness Comparison of Implant Abutments Produced with Different Materials and Techniques by AFM and SEM and Investigation of Microbiological Retention Aim: The aim of this study was to investigate whether there is a difference in the surface roughness among abutments produced with different materials and methods by AFM and SEM analyses and microbiological analysis and comparison of Streptococcus Mutans and Candida Albicans adhesion to abutments produced with different materials and methods. Materials and Methods: The material/technique combinations used in the study were Cr-Co Metal Alloy produced by casting method, Cr-Co Metal Alloy produced by CAD-CAM Milling method, Titanium (Grade 5) produced by CAD-CAM Milling method, Zirconia produced by CAD-CAM Milling method, Titanium produced by CAD-CAM Milling method and colored with anodization method, Cr-Co Metal Alloy produced by Laser Sintering method, and stock abutments (Titanium Grade 5) obtained from the factory as a control group. According to the power analysis, a total of 49 samples, with 7 samples per group, were prepared in disk shape with dimensions of 5 mm x 2 mm. After standardization with the methods described in the literature, polishing procedures were applied to each group after production. Each prepared sample was examined using an Atomic Force Microscope (AFM) and then a Scanning Electron Microscope (SEM), and the values related to the surface characteristics were recorded. These findings were statistically evaluated using Kruskal-Wallis and non-parametric tests. Then, for all groups, 3 samples per group were used to inoculate Streptococcus Mutans and Candida Albicans, and the total number of microorganisms after 8 hours and 24 hours were counted. The obtained data were recorded, and the findings were statistically evaluated using ANOVA and Tukey HSD tests. Results: When surface roughness parameters were examined, statistically significant differences were found between groups for Ra, Rq, and Rmax values (p

Benzer Tezler

  1. Implantüstü protezlerde farklı materyal ve tekniklerle hazırlanmış protez alt yapılarının pasif uyumlarının sonlu elemanlar analizi ile değerlendirilmesi

    A finite element analysis: Passive fit of implant supported dentures frameworks prepared with different materials and technics

    GİZEM NUR ÖZTÜRK

    Doktora

    Türkçe

    Türkçe

    2019

    Diş Hekimliğiİstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. BELKIS GÜLSEN BAYRAKTAR

  2. Dijital ölçü aşamasında kullanılan titanyum ve peek tarama gövde materyallerinin yer değiştirmeye bağlı hassasiyetinin değerlendirilmesi

    Evaluation of displacement precision of titanium and peek scan body materials used in digital impression

    EMRE DİKER

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2021

    Diş HekimliğiAnkara Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. SEDAT HAKAN TERZİOĞLU

  3. Farklı tekniklerle üretilmiş implant üstü dayanak ve kronların in-vitro olarak karşılaştırılması

    In-vitro comparison of implant-supported single crowns and abutments manifactured with different techniques

    İREM ÇÖTERT MERCAN

    Doktora

    Türkçe

    Türkçe

    2021

    Diş HekimliğiEge Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. MÜBİN SITKI ULUSOY

  4. 'All-on-Four' hibrid protezler için farklı tekniklerle üretilen PEEK altyapının mekanik dayanım ve stres analizlerinin karşılaştırılması

    Comparison of mechanical strength and stress analysis of PEEK framework manufactured with different techniques for 'All-on-Four' hybrid prosthesis

    MUSTAFA GÜRKAN

    Doktora

    Türkçe

    Türkçe

    2022

    Diş HekimliğiEge Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. TOMURCUK ÖVÜL KÜMBÜLOĞLU

  5. CAD/CAM sistemleri kullanılarak üretilen üç üyeli implant destekli sabit bölümlü protez altyapılarının marjinal ve internal uyumlarının karşılaştırılması

    Comparison of marginal and internal adaptation in the frameworks of three-unit implant supported fixed partial denture produced by using CAD/CAM systems

    ÖZLEM KAYIKÇI

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2020

    Diş HekimliğiRecep Tayyip Erdoğan Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. SABİT MELİH ATEŞ