Ortodontik şeffaf plak materyal ve kalınlık farklılıklarının ankraj ataşmanına uyumunun karşılaştırılması: Bir in vitro çalışma
Micro-CT comparison of aligner fitting on anchorage attachment: An in vitro study
- Tez No: 860001
- Danışmanlar: DR. ÖĞR. ÜYESİ EYÜP BURAK KÜÇÜK
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: şeffaf plak uyumu, ataşman, mikro-bt, clear aligner fitting, attachment, micro-ct
- Yıl: 2023
- Dil: Türkçe
- Üniversite: Hatay Mustafa Kemal Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 86
Özet
Giriş ve Amaç: Bu çalışmanın amacı, farklı kalınlık ve materyalden üretilen ortodontik şeffaf plakların rektanguler ankraj ataşmanına uyumunun in vitro olarak karşılaştırılmasıdır. Gereç ve Yöntem: Çalışmada her bir grupta 10; toplam 40 adet CA Clear Aligner marka şeffaf plak materyali kullanılmıştır. Master model üzerinde birinci ve ikinci küçük azı dişlerine aynı formda iki adet vertikal rektanguler ataşman yerleştirilerek her bir grupta 10 plak üzerinde toplam 20 ataşmanın uyumu değerlendirilmiştir. Çalışmada; 0,5mm CA-Soft, 0,625 mm CA-Medium, 0,75 mm CA-Hard PET-G ve 0,75 mm CA PRO-Hard ABA Three Layer Material olmak üzere 4 farklı materyal ve kalınlıkta plak kullanılmıştır. Plaklar tek bir rezin modele basılmış; ölçümler için mikro bilgisayarlı tomografi yöntemi kullanılmıştır. Üç boyutlu (3B) analiz için ataşman ile plak arasındaki hava boşluğu hacmi; iki boyutlu (2B) analizler için de frontal, sagital ve transversal düzlemde ataşmanın başladığı, bittiği ve ortanca kesitte 8 noktada ataşman ile plak arasındaki mesafe ölçülmüştür. Sonrasında ölçülen 8 noktanın ortalaması alınarak o kesitin ortalama boşluk genişliği (OBG) hesaplanmış ve karşılaştırmalar yapılmıştır. Gruplar arası karşılaştırmalar tek yönlü varyans analizi (ANOVA) ve Tukey HSD çoklu karşılaştırma testleri ile yapılmıştır. Grup içinde tekrarlayan ölçümlerde karşılaştırmalar ANOVA ve LSD testi ile değerlendirilmiştir. Bulgular: 3B analiz sonuçlarına göre ataşman-şeffaf plak arasında kalan boşluk hacmi açısından gruplar arasında istatistiksel olarak anlamlı bir fark bulunmamaktadır. 2B analiz sonuçlarına göre frontal düzlemde; palatinal kesitte CA PRO-Hard grubunda OBG diğer gruplardan daha düşüktür. Grup içi kıyaslamalarda; tüm çalışma gruplarında bukkal kesitin OBG palatinal kesite göre daha düşük bulunmuştur. Sagital düzlemde; mezial kesitte gruplar arasında istatistiksel olarak anlamlı fark bulunmamaktadır. Sagitomedian ve distal kesitte CA PRO-Hard grubunda OBG; diğer gruplardan daha düşük bulunmuştur. Grup içi kıyaslamalarda; CA PRO-Hard grubunda kesitler arasında OBG açısından fark gözlemlenmemiştir. Diğer gruplarda mezial ve distal kesit OBG; sagitomedian kesite göre daha düşük bulunmuştur. Transversal düzlemde; gingival ve transversomedian kesitte CA PRO-Hard grubunda OBG diğer çalışma gruplarına göre daha düşük bulunmuştur. Oklüzal kesitte gruplar arasında istatistiksel olarak anlamlı fark bulunmamaktadır. Grup içi kıyaslamalarda; CA-Soft, CA-Medium ve CA-Hard grubunda oklüzal kesitten gingival kesite doğru daha büyük OBG gözlemlenmiştir. CA PRO-Hard grubunda OBG gingival kesit, oklüzal kesite göre daha düşük bulunmuştur. Düzlem ortalamalarında ise gruplar arasında, her üç düzlemde de CA PRO Hard grubu OBG diğer gruplara göre daha düşük bulunmuştur. Sonuç: 3B analiz sonuçlarına göre tüm gruplarda plak-ataşman uyumu birbirine benzer bulunmuştur. 2B analiz sonuçlarına göre genel olarak diş-ataşman birleşiminde ve gingival bölgede uyum kaybı gözlemlenmiştir. CA PRO-Hard tüm ataşman yüzeylerinde daha iyi uyum göstermiştir.
Özet (Çeviri)
Introduction and Aim: The aim of this study was to compare in vitro the fitting of orthodontic clear aligners of different thicknesses and materials to the anchorage attachment. Material and Methods: In the study, 10 in each group and a total of 40 CA Clear Aligner brand clear aligners were used. Two vertical rectangular attachments of the same form were placed on the first and second premolars on the master model and the fitting (gap between aligners and tooth surface) of a total of 20 attachments on 10 plates in each group was evaluated. In the study; 4 different aligners were used; 0.5mm CA-Soft, 0.625 mm CA-Medium, 0.75 mm CA-Hard PET-G and 0.75 mm CA PRO-Hard ABA Three Layer Material. The aligners were printed on a single resin model and the micro-computed tomography method was used to measure the air gap volume and gap width between the clear aligner and the attachment. For three-dimensional (3D) analysis, the air gap between the attachment and the aligner was measured; for two-dimensional (2D) analysis, the distance between the attachment and the aligner was measured at 8 points at the beginning, ending and median section of the attachment in the frontal, sagittal and transversal planes. The average gap width (AGW) of that section was then measured by averaging the 8 measured points. Comparisons between groups were made with one-way analysis of variance (ANOVA) and Tukey HSD multiple comparison tests. Within-group comparisons in repeated measurements were evaluated by ANOVA and LSD test. Results: According to the 3D analysis results, there is no statistically significant difference between the groups in terms of the gap volume between the attachment and the clear aligner. According to the 2D analysis results, in the frontal plane; AGW in the CA PRO-Hard group in the palatinal section is lower than the other groups. In within-group comparisons, the OBG of the buccal section was found to be lower than the palatinal section in all study groups. In the sagittal plane; there is no statistically significant difference between the groups in the mesial section. In the sagitomedian and distal sections, AGW in the CA PRO-Hard group was found to be lower than the other groups. In within-group comparisons, no difference was observed in terms of AGW between sections in the CA PRO Hard group. In other groups, mesial and AGW of distal section was found to be lower than sagitomedian section. In the transversal plane; in the gingival and transversomedian sections, AGW was found to be lower in the CA PRO-Hard group compared to the other study groups. In within-group comparisons, OBG gingival section was found to be lower than occlusal section in CA PRO-Hard group. In the other groups, a larger OBG was observed from occlusal to gingival sections. In the plane averages, AGW of CA PRO Hard group was found to be lower than the other groups in all three planes. Conclusion: According to the 3D analysis results, the fitting of all groups was similar to each other. According to the results of the 2D analysis, a loss of fitting was generally observed at the tooth-attachment junction and in the gingival area. CA PRO-Hard showed a better fitting on all attachment surfaces.
Benzer Tezler
- Ortodontik tedavi amaçlı doğrudan baskı ile üretilen yeni bir aligner plağı ile farklı güncel termoplastik aligner plaklarının fiziko-mekanik özelliklerinin karşılaştırılması
Comparison of the physico-mechanical properties of A new aligner material produced by direct printing for orthodontic treatment purposes and different current thermoplastic aligner materials
BETÜL BALLI DEMİREL
- Farklı kalınlıklardakı sabıt Lıngual retaıner tellerının ındırekt ve dırekt yapıştırma teknıklerı ıle uygulandıklarında gıngıval dokularüzerındekı etkılerının ve başarı oranlarının ın vıvo karşılaştırılması
In vivo comparison of gingival tissue effects and success rates of fixed Lingual retainers of different thicknesses applied with direct and indirect adhesive techniques
BEGÜM GÖKÇE TİRİTOĞLU
Diş Hekimliği Uzmanlık
Türkçe
2017
Diş HekimliğiBaşkent ÜniversitesiOrtodonti Ana Bilim Dalı
DOÇ. DR. BURÇAK KAYA
- Şeffaf plak ile yapılan minivida destekli en masse retraksiyon uygulamalarında farklı tasarımların etkisinin sonlu elemanlar analizi ile karşılaştırılması
Comparison of the effect of different designs on en masse retraction applications with clear aligners using finite element analysis
ELA EUSMANAGA
Doktora
Türkçe
2023
Diş Hekimliğiİstanbul Aydın ÜniversitesiOrtodonti Ana Bilim Dalı
DOÇ. DR. AYLİN PAŞAOĞLU BOZKURT
- Farklı şeffaf plak materyallerinin fiziksel özelliklerinin karşılaştırılması
Başlık çevirisi yok
AHMET MURAT ARTUÇ
- Şeffaf plak tekniğinde kullanılan farklı kompozit ataşmanların ve üçüncü molar varlığının maksiller molar distalizasyonuna etkisinin sonlu elemanlar metodu ile incelenmesi
Investigation of the effect of different composite attachments used and the presence of the third molar on maxillary molar distalization in the clear aligner technique using the finite element method
ASLIHAN KUĞUOĞLU
Diş Hekimliği Uzmanlık
Türkçe
2023
Diş HekimliğiHacettepe ÜniversitesiOrtodonti Ana Bilim Dalı
DOÇ. DR. BENGİSU AKARSU GÜVEN