Geri Dön

Üst ekstremite problemi olan bireylerde hareket imgeleme anketi-3 ve kinestetik ve görsel imgeleme anketi-20'nin psikometrik özelliklerinin araştırılması

Investigation of the psychometric properties of movement imagery questionnaire-3 and kinesthetic and visual imagery questionnaire-20 in individuals with upper extremity problems

  1. Tez No: 862204
  2. Yazar: SEDA KOPARAN
  3. Danışmanlar: PROF. DR. ÇİĞDEM AYHAN KURU
  4. Tez Türü: Yüksek Lisans
  5. Konular: Ortopedi ve Travmatoloji, Fizyoterapi ve Rehabilitasyon, Orthopedics and Traumatology, Physiotherapy and Rehabilitation
  6. Anahtar Kelimeler: Üst ekstremite, imgeleme, psikometri, geçerlik çalışması, anketler ve ölçekler, Upper Extremity, Imagery, Psychometrics, Validation Study, Surveys and Questionnaire
  7. Yıl: 2026
  8. Dil: Türkçe
  9. Üniversite: Hacettepe Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Kas İskelet Fizyoterapisi ve Rehablitasyon Ana Bilim Dalı
  12. Bilim Dalı: Ortopedik Fizyoterapi ve Rehabilitasyon Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmanın birincil amacı, Hareket İmgeleme Anketi-3 (HİA-3) ve Kinestetik ve Görsel İmgeleme Anketi-20 (KGİA-20) Türkçe versiyonlarının üst ekstremite problemi olan bireylerde güvenirlik ve geçerliliğini incelemekti. İkincil amaç, kırık, yumuşak doku ve periferik sinir yaralanması gruplarında motor imgeleme düzeylerini sağlıklı bireylerle karşılaştırmaktı. Yaşları 38–60 arasında değişen klinik gruplar (yumuşak doku yaralanması (n=41), kırıklar (n=40) ve periferik sinir yaralanması (n=40)) ile yaşları 29–53 arasında değişen sağlıklı bireylerden (n=38) oluşan toplam 159 birey çalışmaya dahil edildi. Test–tekrar test güvenirliği (ICC), iç tutarlılık (Cronbach alfa), Bland–Altman analizi ve yapı geçerliliği değerlendirildi. Ayrıca bilinen gruplar/ayırt edici geçerlik ile seçili klinik, psikososyal ve bilişsel ölçütlerle yakınsak–ayrışık geçerlik Spearman korelasyonlarıyla incelendi. HİA-3'ün test–tekrar test güvenirliği ICC=0,87, iç tutarlılığı Cronbach alfa=0,963 bulundu ve faktör analizleri tek faktörlü yapıyı destekledi. ROC analizi, HİA-3'ün sağlıklı ve klinik grubu orta düzeyde ayırt ettiğini gösterdi (AUC=0,693; p<0,001). KGİA-20 toplam ve alt boyut puanları yüksek güvenirlik sergiledi (Cronbach alfa=0,954–0,975; ICC=0,894–0,920) ve doğrulayıcı faktör analizi iki faktörlü yapının iyi uyum verdiğini gösterdi. HİA-3 ve KGİA-20 arasında yüksek düzeyde yakınsak ilişki saptandı (rₛ=0,735; p<0,05). Kruskal–Wallis testi sonuçlarına göre, gruplar arasında HİA-3 toplam puanı ile KGİA-20 toplam, görsel ve kinestetik alt boyut puanları açısından anlamlı fark bulundu (p<0,001). Yumuşak doku yaralanması grubu HİA-3 puanları açısından daha yüksek skor aldı (p=0,004). Sonuç olarak, HİA-3 ve KGİA-20 Türkçe versiyonları güvenilir ve geçerli ölçüm araçlarıdır; HİA-3 motor imgelemeyi genel, KGİA-20 ise görsel ve kinestetik alt boyutlarıyla değerlendirir.

Özet (Çeviri)

The primary aim of this study was to examine the reliability and validity of the Turkish versions of the Movement Imagery Questionnaire-3 (MIQ-3) and the Kinesthetic and Visual Imagery Questionnaire-20 (KVIQ-20) in individuals with upper extremity problems. The secondary aim was to compare motor imagery levels among individuals with fractures, soft tissue injuries, peripheral nerve injuries, and healthy individuals. A total of 159 participants were included: clinical groups aged 38–60 years [soft tissue injury (n=41), fractures (n=40), and peripheral nerve injury (n=40)] and healthy individuals aged 29–53 years (n=38). Test–retest reliability (ICC), internal consistency (Cronbach's alpha), Bland–Altman analysis, and construct validity were evaluated. Known-groups/discriminant and convergent–divergent validity with selected clinical, psychosocial, and cognitive measures were examined using Spearman correlations. The MIQ-3 showed good test–retest reliability (ICC=0.87), excellent internal consistency (Cronbach's alpha=0.963), and a single-factor structure, and moderately discriminated healthy and clinical groups (AUC=0.693; p<0.001). The KVIQ-20 demonstrated high reliability (Cronbach's alpha=0.954–0.975; ICC=0.894–0.920), and confirmatory factor analysis supported a two-factor structure. A strong convergent relationship was observed between the MIQ-3 and KVIQ-20 (rₛ=0.735; p<0.05). Divergent validity showed moderate associations of the MIQ-3 with visual intelligence and sensation, and of the KVIQ-20 with sensation. Kruskal–Wallis analysis revealed significant group differences in MIQ-3 total and KVIQ-20 total, visual, and kinesthetic scores (p<0.001), with higher MIQ-3 scores in the soft tissue injury group (p=0.004). In conclusion, the Turkish MIQ-3 and KVIQ-20 are reliable and valid tools; MIQ-3 assesses general motor imagery, whereas KVIQ-20 provides detailed visual and kinesthetic assessment.

Benzer Tezler

  1. Ege bölgesi keçi liflerinin bazı önemli fiziksel, kimyasal özellikleri ve değerlendirme imkanları

    Başlık çevirisi yok

    NİLÜFER ERDEM

    Doktora

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Tekstil Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  2. Bir pamuk iplikhanesinde fiili çalışma metodlarının incelenmesi ve mevcut işlemlerin standart sürelerinin saptanması

    Başlık çevirisi yok

    MÜRŞİDE KESEROĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Tekstil Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  3. Üst ekstremite periferik sinirlerinin travmatik yaralanmalarında cihaz ve atellemeler

    Başlık çevirisi yok

    SERAP ALSANCAK

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Gazi Üniversitesi

    Yükleniyor...

  4. İzmir Körfezinde kullanılan gırgır ağları üzerinde araştırmalar

    Başlık çevirisi yok

    ADNAN TOKAÇ

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Zootekni Ana Bilim Dalı

    Yükleniyor...