Geri Dön

Pasif ayarlı sıvı kolon sönümleyicilerde delikler arasındaki boşluğun sönümleme performansına etkisinin incelenmesi

Investigation of the effect of the spacing between orifices on the damping performance in passive-tuned liquid column dampers

  1. Tez No: 896021
  2. Yazar: OZAN KARAKUŞ
  3. Danışmanlar: DOÇ. DR. ÜNVER ÖZKOL
  4. Tez Türü: Yüksek Lisans
  5. Konular: Makine Mühendisliği, Mechanical Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2024
  8. Dil: İngilizce
  9. Üniversite: İzmir Yüksek Teknoloji Enstitüsü
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Enerji Bilim Dalı
  13. Sayfa Sayısı: 55

Özet

Yapısal hareketler, sönümley􀵴c􀵴 tasarımı ve bunların 􀵴l􀵴şk􀵴ler􀵴 yapı d􀵴nam􀵴ğ􀵴n􀵴n ana konularıdır. Sönümleme s􀵴stemler􀵴, oluşab􀵴lecek her türlü dış uyartımı d􀵴kkate alarak yapıları stab􀵴l􀵴ze etmek 􀵴ç􀵴n tasarlanmıştır. Yapısal hareketler􀵴n azaltılması yapıların bütünlüğünü koruyab􀵴lmes􀵴 açısından son derece öneml􀵴d􀵴r. Bu sönümleme s􀵴stemler􀵴 genel olarak akt􀵴f ve pas􀵴f sönümleme s􀵴stemler􀵴 olmak üzere 􀵴k􀵴 sınıfta toplanır. Pas􀵴f Ayarlı Sıvı Kolon Sönümley􀵴c􀵴ler -TLCD- bas􀵴t yapıları ve dışarıdan b􀵴r enerj􀵴 g􀵴r􀵴ş􀵴 gerekt􀵴rmemes􀵴 neden􀵴yle prat􀵴kte terc􀵴h ed􀵴len s􀵴stemlerd􀵴r ve bu nedenle yapısal salınımların bastırılmasında etk􀵴n b􀵴r şek􀵴lde kullanılab􀵴l􀵴rler. Bu tezde, TLCD'n􀵴n sönüm performansı, özell􀵴kle yük kaybı katsayısının sıvı kolon performansı üzer􀵴ndek􀵴 etk􀵴s􀵴 d􀵴kkate alınarak 􀵴ncelenm􀵴şt􀵴r. Anal􀵴t􀵴k b􀵴r model üret􀵴ld􀵴 ve hareket denklem􀵴 1 boyutlu olarak çözüldü. İk􀵴 del􀵴ğ􀵴n b􀵴rb􀵴r􀵴ne yakın olması durumunda anal􀵴t􀵴k çözümler􀵴n doğrulanması ve anal􀵴t􀵴k model􀵴n yeterl􀵴 olmadığı durumlarda da b􀵴lg􀵴 elde etmek amacıyla deneyler yapılmıştır. Yük kaybı katsayısının hesaplanması b􀵴rçok çalışmada araştırılmış ve amp􀵴r􀵴k formülasyonlar öner􀵴lm􀵴şt􀵴r, ancak sıvı kolonun yük kaybı değer􀵴 b􀵴r d􀵴z􀵴 deney uygulanarak elde ed􀵴leb􀵴l􀵴r. Ayarlanmış sıvı kolon damper􀵴n􀵴n yük kaybı değer􀵴n􀵴 elde etmek 􀵴ç􀵴n deneysel b􀵴r tasarım kullanıldı. Yük kaybı katsayısının, ayarlanmış sıvı kolon damperler􀵴n􀵴n sönümleme performansı üzer􀵴ndek􀵴 etk􀵴s􀵴n􀵴 gözlemlemek 􀵴ç􀵴n b􀵴r d􀵴z􀵴 deney tamamlandı. Deneysel ve anal􀵴t􀵴k sonuçlara göre s􀵴stem􀵴n sönüm oranı 􀵴le damper􀵴n yük kayıp katsayısı arasında b􀵴r 􀵴l􀵴şk􀵴 tesp􀵴t ed􀵴lm􀵴şt􀵴r. TLCD'n􀵴n performansının maks􀵴muma çıkarılab􀵴leceğ􀵴 􀵴k􀵴 del􀵴k arasında opt􀵴mum b􀵴r aralık olduğu deneysel olarak tesp􀵴t ed􀵴lm􀵴şt􀵴r. Ayrıca deneysel sonuçlara göre s􀵴stem􀵴n sönümleme katsayısının %10.5 oranında gel􀵴şt􀵴ğ􀵴 not ed􀵴lm􀵴şt􀵴r.

Özet (Çeviri)

Damping systems are designed to stabilize the structures by concerning any types of external excitations that can occur. Decreasing the structural movements is extremely important for structures to preserve their integrity. Passive Tuned Liquid Column Dampers -TLCD- are preferred systems in practice due to their simple structures and not requiring an external energy input and therefore, they can be effectively used in the suppression of structural oscillations. In this thesis, the damping performance of a TLCD was studied, specifically considering the effect of the head loss coefficient on the performance of a liquid column. An analytical model was produced, and the equation of motions was solved in 1D. Experiments were performed to confirm the analytical solutions and to gain information where the analytical model was not sufficient in the case of two orifices that were close to each other. An experimental design was used to obtain the head loss value of the tuned liquid column damper. A series of experiments were completed to observe the effect of the head loss coefficient on the damping performance of the tuned liquid column dampers. According to experimental and analytical results, a relation between the damping ratio of the system and the head loss coefficient of the damper was noted. It was experimentally monitored that there is an optimum spacing between two orifices where the performance of the TLCD may be maximized. It was also noted that, according to experiments damping ratio of the system was improved by 10.5%.

Benzer Tezler

  1. Ayarlı sıvı sönümleyicilerin betonarme binaların deprem performansına etkisinin incelenmesi

    Investigation of the effect of tuned liquid dampers on earthquake performance of reinforced concrete buildings

    BİRKAN DAĞ

    Yüksek Lisans

    Türkçe

    Türkçe

    2022

    İnşaat Mühendisliğiİstanbul Teknik Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    PROF. DR. MUSTAFA GENÇOĞLU

    DR. ÖĞR. ÜYESİ MUZAFFER BÖREKÇİ

  2. Design optimization of a hybrid vibration control system for buildings structures

    Bina yapıları için bir hibrit titreşim kontrol sisteminin tasarım optimizasyonu

    BASEL SALAAS

    Yüksek Lisans

    İngilizce

    İngilizce

    2023

    Deprem Mühendisliğiİstanbul Üniversitesi-Cerrahpaşa

    İnşaat Mühendisliği Ana Bilim Dalı

    PROF. DR. GEBRAİL BEKDAŞ

  3. Ayarlı sıvı sönümleyicilerin yapılar için optimizasyonu

    Optimization of tuned liquid dampers for structures

    AYLA OCAK

    Yüksek Lisans

    Türkçe

    Türkçe

    2021

    İnşaat Mühendisliğiİstanbul Üniversitesi-Cerrahpaşa

    İnşaat Mühendisliği Ana Bilim Dalı

    DOÇ. DR. GEBRAİL BEKDAŞ

  4. Yapısal kontrol sistemleri ve sıvı sönümleyicilerin yapılarda kullanımı

    Structural control systems and the use of liquid dampers on the structures

    ERSAN SANSARCI

    Yüksek Lisans

    Türkçe

    Türkçe

    2002

    İnşaat Mühendisliğiİstanbul Teknik Üniversitesi

    Yapı Mühendisliği Ana Bilim Dalı

    DOÇ. DR. A. NECMETTİN GÜNDÜZ

  5. Hibrid metasezgisel algoritmalar kullanılarak betonarme yapı ve elemanları ile kütle sönümleyici optimizasyonu

    Optimization of reinforced concrete structure and elements and mass dampers using hybrid metaheuristic algorithms

    MUHAMMED ÇOŞUT

    Yüksek Lisans

    Türkçe

    Türkçe

    2022

    İnşaat Mühendisliğiİstanbul Üniversitesi-Cerrahpaşa

    İnşaat Mühendisliği Ana Bilim Dalı

    PROF. DR. GEBRAİL BEKDAŞ