Geri Dön

In vitro comparison of the retention in two different implant abutment systems

İki farkli dayanak sistemi üzerine yerleştirilen kronların tutuculuğunun kıyaslanması

  1. Tez No: 910785
  2. Yazar: SARAH ALNMKI
  3. Danışmanlar: PROF. DR. YASEMİN ÖZKAN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Dental bonding, Dental destekler, Dental protez-implant destekli, Dental restorasyon, Dental stres analizi, Kronlar, Takma diş tabanları, Dental bonding, Dental abutments, Dental prosthesis-implant supported, Dental restoration, Dental stress analysis, Crowns, Denture bases
  7. Yıl: 2022
  8. Dil: İngilizce
  9. Üniversite: Marmara Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Restorasyonların optimal dayanıklılığı için çiğneme kuvvetlerine karşı stabilite ve uygun retansiyon kritik öneme sahiptir. Bu in vitro çalışmanın amacı, iki farklı implant-abutment sisteminde dinamik yükleme öncesi ve sonrası retansiyonu karşılaştırmaktır. Gereç ve yöntem: Bu invitro çalışmada 16 adet implant kullanılmıştır. İmplant-abutment sistemine göre iki gruba ayrılmıştır: Grup A; 8 implant TiDesign dayanağa bağlı, ve Grup B; 8 implant Acuris dayanak. Tüm dayanakların üstüne Lityum disilikat (IPS e.max CAD, Ivoclar Vivadent, Lihtenştayn) kronlar ile üretilmiştir. Tutuculuk, Instron (Evrensel Test Makinesi) kullanılarak ölçülmüş, ve her bir kronu yerinden çıkarmak için gereken yük Newton cinsinden kaydedilmiştir. Tutuculuk, hem statik hem de dinamik yüklemeden sonra ölçülmüştür. Veriler IBM SPSS V23 ile istatistiksel olarak analiz edilmiştir. Bulgular: Sonuçlar, çiğnemeden önce istatistiksel olarak anlamlı bir sonucun elde edildiğini göstermektedir. Bununla birlikte, çiğneme sonrası önemli bir fark gözlenmemiştir. Grup A ve Grup B'nin çiğneme öncesi ortalama değeri sırasıyla 839.3 ve 183.2 N'dur. Benzer şekilde, çiğneme sonrası değerler grup A ve grup B için sırasıyla 376.4 ve 146.4 N olarak bulunmuştur. Sonuçlar, çiğneme öncesi ve sonrası değerlerin karşılaştırılması açısından istatistiksel olarak anlamlıdır. Sonuç: Bu in vitro çalışmanın sınırlaması dahilinde, Acuris sisteminin tutuculuğunun dinamik yüklemeden sonra siman tutuculu restorasyonlardan daha iyi olduğu sonucuna varılabilir.

Özet (Çeviri)

Objective: Stability against masticatory forces and proper retention are critical for optimal durability of restorations. The aim of this in vitro study was to compare the retention before and after dynamic loading in two different implant-abutment systems. Materials and Methods: In this in vitro study 16 implants. Will be divided to two groups according to the implant-abutment system, Group A; 8 implants connected to TiDesign Abutment and Group B; 8 implant connected to Acuris abutment.Lithium disilicate (IPS.e.max CAD, Ivoclar Vivadent, Liechtenstein) crowns were fabricated. The retention is measured using Instron (Universal Testing Machine) load required to dislodge each crown will be recorded in newtons. The retention is measured after both static and dynamic loading. Data were statistically analyzed with IBM SPSS V23. Results: The results show that a statistically significant outcome was obtained before chewing. However, no significant difference was observed post-chewing. Group A and Group B had a mean value of 839.3 and183.2 N before chewing respectively. Similarly, post-chewing the values were 376.4 and 146.4 N for group A and group B respectively. The results are statistically significant in terms of comparison between the before and after chewing values. Conclusion: within the limitations of this in-vitro study it can be concluded that the retention of the Acuris system is better than cement retained after dynamic loading.

Benzer Tezler

  1. Ovulasyon indüksiyonu tedavisinde folliküler gelişimin ultrasonografik takibi

    Başlık çevirisi yok

    MERİH BAYRAM

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    Kadın Hastalıkları ve DoğumGazi Üniversitesi

    Kadın Hastalıkları ve Doğum Ana Bilim Dalı

    DOÇ. DR. MÜLAZIM YILDIRIM

  2. Çimentonun sertleşmesi üzerinde kimyasal komponentlerin etkisi

    Başlık çevirisi yok

    NACİYE TÜRKEL

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Kimya MühendisliğiUludağ Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. MUSTAFA CEBE

  3. Bazı esterlerin kinetik incelenmesi ve termodinamik parametrelerin belirlenmesi

    Kinetic study and detesmination of thermodnamic parameters of some esters

    İBRAHİM TAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Kimya MühendisliğiUludağ Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. MUSTAFA CEBE

  4. Atherosklerotik kalp hastalıklarında risk faktörleri

    Risk factors in the coronary artery disease

    MURAT SUHER

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    KardiyolojiGazi Üniversitesi

    İç Hastalıkları Ana Bilim Dalı

  5. Diesel motorları yakıt püskürtme sistemlerinin dinamik simülasyonu

    Başlık çevirisi yok

    İRFAN KARAGÖZ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Makine MühendisliğiUludağ Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. OĞUZ BORAT