Yoğun bakım ünitesinde yatan hastalarda nem, ısı, gürültü ve ışık düzeylerinin uyku kalitesi ve konfor üzerine etkisi
Effects of humidity, heat, noise and light levels on sleep quality and comfort in patients admitted to the intensive care unit
- Tez No: 948908
- Danışmanlar: PROF. DR. TÜRKİNAZ AŞTI, DOÇ. DR. NURAY TURAN
- Tez Türü: Yüksek Lisans
- Konular: Hemşirelik, Nursing
- Anahtar Kelimeler: Environmental factors, noise, nursing care, light, heat, comfort, humidity, sleep quality, intensive care unit
- Yıl: 2025
- Dil: Türkçe
- Üniversite: Bezm-i Alem Vakıf Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Hemşirelik Ana Bilim Dalı
- Bilim Dalı: Hemşirelik Esasları Bilim Dalı
- Sayfa Sayısı: 116
Özet
ÖZET Bu araştırma, yoğun bakım ünitesinde yatan hastalarda çevresel faktörlerden olan nem, ısı, gürültü ve ışık düzeylerinin uyku kalitesi ve konfor düzeyi üzerindeki etkilerini belirlemek amacıyla yapılmıştır. Tanımlayıcı ve ilişki arayıcı tasarımda yürütülen bu araştırma, İstanbul'da bir özel hastanenin genel yoğun ünitesi, kardiyovasküler cerrahi yoğun bakım ünitesi ve koroner yoğun bakım ünitesinde Temmuz 2023-Temmuz 2024 tarihleri arasında gerçekleştirilmiştir. Araştırmanın örneklemini, dâhil edilme kriterlerini karşılayan ve çalışmaya katılmaya gönüllü olan 89 hasta oluşturmuştur. Veriler; Hasta Bilgi Formu, Glasgow Koma Skalası (GKS), Richards Campbell Uyku Ölçeği ve Genel Konfor Ölçeği kullanılarak toplanmış; çevresel faktörler ise kalibre edilmiş dijital ölçüm cihazlarıyla hasta başında sistematik olarak değerlendirilmiş ve Nem, Isı, Gürültü ve Işık Düzeyleri Kayıt Formu'na kaydedilmiştir. Ölçümler iki ardışık gün boyunca aynı saat aralıklarında yapılmış, istatistiksel analizler SPSS v27 programında gerçekleştirilmiştir. Yapılan analizler sonucunda, hastaların yoğun bakıma yatışından sonraki 3. ve 4. günlerde ölçülen GKS, nem, ısı, gürültü ve ışık düzeyleri arasında istatistiksel olarak anlamlı bir fark saptanmamıştır (p>0,05). Ancak, çevresel faktörlerden nem, ısı ve gürültünün konfor alt boyutlarıyla bazı zayıf ve anlamlı ilişkiler gösterdiği belirlenmiştir. Özellikle ikinci gün ölçülen ısı ile ferahlama, rahatlama, psikospirütel ve sosyokültürel konfor boyutları arasında negatif yönde; üstünlük ve çevresel konfor boyutları arasında pozitif yönde ilişkiler bulunmuştur (p
Özet (Çeviri)
SUMMARY This study was conducted to determine the effects of environmental factors such as humidity, heat, noise, and light levels on sleep quality and comfort levels in patients hospitalized in the intensive care unit. Conducted with a descriptive and correlational design, this study was carried out between July 2023 and July 2024 in the general intensive care unit, cardiovascular surgery intensive care unit, and coronary intensive care unit of a private hospital in Istanbul. The sample of the study consisted of 89 patients who met the inclusion criteria and voluntarily agreed to participate. Data were collected using the Patient Information Form, Glasgow Coma Scale (GCS), Richards-Campbell Sleep Questionnaire (RCSQ), and the General Comfort Questionnaire (GCQ); environmental factors were systematically assessed at the bedside using calibrated digital measuring devices and recorded in the Humidity, Heat, Noise and Light Level Recording Form. Measurements were taken at the same time intervals over two consecutive days, and statistical analyses were performed using the SPSS v27 program. As a result of the analyses, no statistically significant difference was found between the GCS, humidity, heat, noise, and light levels measured on the 3rd and 4th days after ICU admission (p > 0.05). However, it was determined that humidity, heat, and noise—among the environmental factors—showed some weak but significant correlations with the subdimensions of comfort. In particular, on the second day, heat showed negative correlations with the subdimensions of relief, relaxation, psychospiritual, and sociocultural comfort, while showing positive correlations with the subdimensions of transcendence and environmental comfort (p < 0.05). Noise level was found to have a positive correlation with relief and a negative correlation with the sense of transcendence (p < 0.05). Although no direct significant relationship was found between environmental factors and sleep quality, changes in comfort levels were observed to be influenced by environmental stimuli. The findings reveal that environmental factors in the intensive care environment have multidimensional effects on patient comfort. In this context, nursing practices aimed at improving the physical environment may be effective in increasing patient satisfaction and quality of care.
Benzer Tezler
- Mekanik ventilasyon tedavisi alan hastalarda ısıtıcılı nemlendirici ile ısı ve nem değişimi yapan filtre ile beraber booster kullanımının klinik ve bakteriyolojik açıdan karşılaştırılması
Clinical and bacteriological comparison of effects of heated humidifier and HME - booster in mechanically ventilated patients
TÜRKAN NADİR ÖZİŞ
Tıpta Uzmanlık
Türkçe
2007
Göğüs HastalıklarıGazi ÜniversitesiGöğüs Hastalıkları ve Tüberküloz Ana Bilim Dalı
PROF.DR. GÜL GÜRSEL
- Üçüncü düzey çocuk yoğun bakım ünitesinde yatan hastalarda hipoalerjenik flaster ile yapılan göz bakımı uygulamasının Schirmer I testi ile etkinliğinin değerlendirilmesi: Yarı deneysel bir çalışma
Evaluation of the effectiveness of eye care application with hypoallergenic patch with Schirmer I test in patients admitted in a tertiary level pediatric intensive care unit: A quasi-experimental study
KÜBRA BAŞARAN
- Yoğun bakım ünitesinde yatan hastalarda kırılganlık sıklığı ve ilişkili faktörler
Frequency of frailty and related factors in patients in the intensive care unit
HİLAL ARSLAN
Yüksek Lisans
Türkçe
2025
HemşirelikÜsküdar ÜniversitesiHemşirelik Ana Bilim Dalı
DR. ÖĞR. ÜYESİ HATİCE DEMİRDAĞ
- Yoğun bakım ünitesinde yatan hastalarda Candida kolonizasyonunun epidemiyolojik ve invitro antifungal duyarlılık yönünden incelenmesi
Investigation of epidemiological and in vitro antifungal susceptibity of Candida colonization in patients hospitalized in intensive care unit
AYSUN KAYA
Tıpta Yan Dal Uzmanlık
Türkçe
2012
Mikrobiyolojiİstanbul ÜniversitesiTıbbi Mikrobiyoloji Ana Bilim Dalı
PROF. DR. ZAYRE ERTURAN
- Yoğun bakım ünitesinde yatan hastalarda gelişen ventilasyon ilişkili pnömoninin risk faktörlerinin, olası etkenlerinin ve mortalite etkisinin değerlendirilmesi
Evaluation of risk factors, possible agents and mortality of ventilation associated pneumonia developed in patients who stayed in intensive care unit
SÜLEYMAN AKSOY
Tıpta Uzmanlık
Türkçe
2012
Klinik Bakteriyoloji ve Enfeksiyon HastalıklarıKocaeli ÜniversitesiEnfeksiyon Hastalıkları ve Klinik Mikrobiyoloji Ana Bilim Dalı
DOÇ. DR. MELİHA MERİÇ KOÇ