Farklı yüzeyli grade-4 titanyum alaşım implantlar ile niobium implantların osseointegrasyon düzeylerinin biyomekanik incelenmesi
Biomechanical evaluation of osseointegration levels of grade-4 titanium and niobium alloy implants with different surface modifications
- Tez No: 967572
- Danışmanlar: PROF. DR. SERKAN DÜNDAR
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Niyobyum, grade 4, implant yüzeyi, Osseointegrasyon, Niobium, Grade 4, Implant surface, Osseointegration
- Yıl: 2025
- Dil: Türkçe
- Üniversite: Fırat Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Periodontoloji Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 112
Özet
1. ÖZET FARKLI YÜZEYLİ GRADE-4 TİTANYUM ALAŞIM İMPLANTLAR İLE NİOBİUM İMPLANTLARIN OSSEOİNTEGRASYON DÜZEYLERİNİN BİYOMEKANİK İNCELENMESİ Diş kayıplarının tedavisine yönelik arayışlar uzun yıllar boyunca devam etmiş ve bu süreçte geliştirilen dental implant uygulamaları günümüzde başarıyla uygulanarak diş hekimliğinin vazgeçilmez tedavi yöntemlerinden biri haline gelmiştir. İmplant tedavisi, diğer protetik yaklaşımlardan farklı olarak, uygulandığı bölgede komşu diş yapısını ve alveolar kemiği koruma avantajı sağlaması nedeniyle önemli bir tedavi seçeneği olarak öne çıkmaktadır. Ayrıca, tam dişsiz veya parsiyel dişsizlik durumlarında implant rehabilitasyonunun çiğneme etkinliği, fonasyon, estetik görünüm ve genel yaşam kalitesi üzerinde belirgin iyileşmeler sağladığı literatürde bildirilmektedir. Dental implantların başarısını belirleyen en kritik unsur osseointegrasyon sürecidir. Bu biyolojik süreç, implant tedavisinin başarısında veya başarısızlığında temel rol oynamakta ve bazı durumlarda tedavinin tüm sonucunu etkilemektedir. Osseointegrasyonun gerçekleşme düzeyi; implantın yüzey morfolojisi başta olmak üzere pek çok biyolojik ve biyomekanik faktörden etkilenmektedir. Klinik başarı oranlarını artırmak amacıyla, implant yüzeylerinde farklı modifikasyon yöntemleri geliştirilmiş ve bu sayede implantların biyolojik performansı iyileştirilmiştir. Bu çalışmanın amacı farklı yüzeyli grade 4 titanyum implantlar ile niyobyum alaşım implantların karşılaştırılmasıdır. Denekler 6 eşit gruba ayrıldı. Bunlar grade 4 SLA yüzey (n=9), grade 4 torna (n=10), grade 4 RBM (n=10), niyobyum SLA (n=10), niyobyum RBM (n=9) ve niyobyum torna yüzey (n=10) şeklinde gruplara ayrılmıştır. Genel anestezi altında, çalışma grubundaki deneklerin sağ tibiya kemiklerinin metafizyal bölgelerindeki kortikokansellöz kemiğe 2,5 mm çapında ve 4 mm uzunluğunda, yüzey özellikleri farklı implantlar yerleştirilmiştir. On iki haftalık iyileşme sürecinin ardından denekler sakrifize edilmiş ve implantların osseointegrasyon düzeyi biyomekanik ters tork testi ile değerlendirilmiştir. Bu analiz, kemik ile implant arasındaki kaynaşma derecesini belirlemek amacıyla uygulanmıştır. Bu çalışmamızın sonuçlarına baktığımızda; 12 haftanın sonunda grade 4 ve niyobyum alaşımlarından üretilen SLA, RBM ve torna yüzey implantların osseointegrasyonu sağlandığı gözlemlenmiştir. Torna yüzey implantlar hem grade 4 titanyum alaşım implantlarda hem de niyobyum alaşım implantlarda istatistiksel anlamda düşük çıkmıştır. Yüzey özelliklerine göre değerlendirildiğinde SLA ve RBM yüzey implantlar arasında istatistiksel anlamda bir farklılık bulunmamıştır. Alaşım tiplerine göre değerlendirildiğinde grade 4 SLA yüzey implant diğer gruplara göre istatistiksel anlamda yüksek bulunmuştur.
Özet (Çeviri)
2. ABSTRACT BIOMECHANICAL EVALUATION OF OSSEOINTEGRATION LEVELS OF GRADE-4 TITANIUM AND NIOBIUM ALLOY IMPLANTS WITH DIFFERENT SURFACE MODIFICATIONS The search for effective treatment options for tooth loss has continued for decades, during which dental implant applications have been developed and successfully implemented, becoming one of the indispensable treatment modalities of modern dentistry. Unlike other prosthetic approaches, implant therapy offers the advantage of preserving the adjacent tooth structure and alveolar bone in the treated region, thereby standing out as a valuable treatment option. Furthermore, implant rehabilitation in cases of complete or partial edentulism has been reported to provide significant improvements in masticatory efficiency, phonation, esthetics, and overall quality of life. The most critical factor determining the long-term success of dental implants is osseointegration, the direct biological connection between the implant surface and surrounding bone tissue. This process plays a decisive role in the ultimate success of implant therapy and is influenced by numerous biological and biomechanical factors, particularly implant surface morphology. To enhance clinical performance, various surface modification techniques have been developed, thereby improving the biological outcomes of dental implants. The aim of this study was to compare the osseointegration levels of Grade-4 titanium alloy implants and niobium alloy implants with different surface modifications. The experimental animals were divided into six groups: Grade 4-SLA (n=9), Grade 4-turned (n=10), Grade 4-RBM (n=10), Nb-SLA (n=10), Nb-RBM (n=9), and Nb-turned (n=10). Under general anesthesia, implants with different surface characteristics (2.5 mm in diameter and 4 mm in length) were inserted into the cortico-cancellous bone of the metaphyseal region of the right tibia. After a healing period of twelve weeks, the animals were sacrificed, and the degree of osseointegration was assessed using a biomechanical reverse torque test. The findings revealed that osseointegration was achieved in all implants, both Grade-4 titanium and niobium alloys, after 12 weeks of healing. Turned surface implants exhibited significantly lower osseointegration levels in both alloy groups. No statistically significant difference was observed between SLA and RBM surface implants. However, when evaluated by alloy type, Grade-4 SLA surface implants demonstrated statistically higher osseointegration values compared to other groups.
Benzer Tezler
- Characteristics of cold sprayed titanium based coatings
Soğuk gaz dinamik püskürtme yöntemiyle üretilmiş titanyum esaslı kaplamaların karakteristiği
AHMET HİLMİ PAKSOY
Yüksek Lisans
İngilizce
2017
Metalurji Mühendisliğiİstanbul Teknik ÜniversitesiMetalurji ve Malzeme Mühendisliği Ana Bilim Dalı
PROF. DR. MURAT BAYDOĞAN
DOÇ. DR. ERDEM ATAR
- Characteristics and wear performance of nitrided titanium alloys
Nitrürlenmiş titaniyum alaşımların karakteristiği ve aşınma davranışları
FARID SIYAHJANI
Doktora
İngilizce
2015
Metalurji Mühendisliğiİstanbul Teknik ÜniversitesiMetalurji ve Malzeme Mühendisliği Ana Bilim Dalı
PROF. DR. HÜSEYİN ÇİMENOĞLU
- Tavşanlarda kan lipit fraksiyonlarının ve antikoagülan ilaçların farklı yüzey özellikli titanyum yüzeylerini ıslatabilme özelliklerinin incelenmesi
Investigation of blood lipid fractions and anticoagulant drugs' ability to wet titanium surfaces with different surface properties in rabbits
DENİZ ÇAĞLAR
Doktora
Türkçe
2024
Diş Hekimliğiİstanbul ÜniversitesiPeriodontoloji Ana Bilim Dalı
PROF. DR. HALİL ERHAN FIRATLI
- Er:YAG, diyot ve CO2 lazerlerin antimikrobiyal etkilerinin karşılaştırmalı olarak titanyum diskler üzerinde araştırılması
Comparative evaluation of antimicrobial effects of Er:YAG, diode and CO2 lasers on titanium discs
EMRE TOSUN
Doktora
Türkçe
2011
Diş HekimliğiHacettepe ÜniversitesiAğız, Diş, Çene Hastalıkları ve Cerrahisi Ana Bilim Dalı
PROF. DR. FERDA TAŞAR
- Farklı ultrasonik uçların titanyum disklerin pürüzlülüğü üzerine etkisinin değerlendirilmesi
Başlık çevirisi yok
AYSUN DOĞU
Diş Hekimliği Uzmanlık
Türkçe
2022
Diş Hekimliğiİzmir Katip Çelebi ÜniversitesiPeriodontoloji Ana Bilim Dalı
PROF. DR. ŞÜKRÜ ENHOŞ