Geri Dön

Endoskopik intragastrik balon uygulamasında yüksek akışlı nazal oksijen kullanımının etkinliğinin değerlendirilmesi

Evaluation of the effectiveness of high flow nasal oxygen use in endoscopic intragastric balloon application

  1. Tez No: 967666
  2. Yazar: MERVE YILGÖR AKMAN
  3. Danışmanlar: DOÇ. DR. GÜLÇİN AYDIN
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Anestezi ve Reanimasyon, Anesthesiology and Reanimation
  6. Anahtar Kelimeler: Endoskopik intragastrik balon, nazal kanül, yüksek akışlı nazal oksijen, Endoscopic intragastric balloon, high flow nasal oxygen, nasal cannula
  7. Yıl: 2025
  8. Dil: Türkçe
  9. Üniversite: Kırıkkale Üniversitesi
  10. Enstitü: Tıp Fakültesi
  11. Ana Bilim Dalı: Anestezi ve Reanimasyon Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Sedasyon; ilaç kaynaklı sakinlik, dinlenme veya uyuşukluk durumunu tanımlamak için kullanılan bir terimdir. Cerrahi ve minimal invaziv prosedürlerde sedatif, anksiyolitik ve analjezik farmakoterapiler kullanılır. Geçici ve minimal invaziv bir tedavi yöntemi olan endoskopik intragastrik balon (EİB) tedavisi, günümüzde hafif düzeydeki obezite için ana tercihtir. Klinik tedaviye yanıt vermeyen, cerrahi için aday olmayan veya cerrahi bir prosedüre girmek istemeyen aşırı kilolu ve obez hastalar için uygun bir seçenektir. Cerrahi veya minimal invaziv prosedürler sırasında hastaya nazal kanül, basit yüz maskesi, rezervuarlı maskeler ve difüzör maskeler gibi yavaş akımlı sistemler [<15 litre (L)/dk akım hızı] ile veya ventüri maske ve yüksek akışlı nazal kanül gibi yüksek akımlı sistemler ile oksijen uygulanır. Nazal kanüller ile 1-6 L/dk akım hızında oksijen uygulanabilir. Yüksek akımlarda verilen oksijen inspire edilen oksijen fraksiyonu (FiO₂)'yi %45'ten fazla artıramaz ve özellikle 4 L/dk'dan daha yüksek akım hızlarında müköz membranlarda kuruma oluşabilir. Yüksek akışlı nazal oksijen (HFO); gazın ısıtıldığı, nemlendirildiği ve büyük çaplı nazal kanüller aracılığıyla iletildiği; bu yolla da hastanın konforunu ve toleransını artıran bir yöntemdir. HFO geleneksel oksijen iletim sistemlerine göre daha yüksek oksijen akış hızları ve daha hassas FiO₂ sağlayabilmektedir. Gaz akış hızı genellikle 30–70 L/dak arasında ayarlanır ve %21 ile %100 arasında değişen FiO₂ iletimine olanak tanır. Obez hastalarda; oluşan çok sayıdaki anatomik, fizyolojik değişiklik ve artan oksijen tüketimine bağlı olarak hipoksemiye eğilim artmıştır. EİB uygulaması yapılan obez hastalar anatomik, fizyolojik, sistemik farklılıklara bağlı olarak ve endoskopik girişim sırasında ve verilen anestezik ilaca bağlı üst solunum yolu obstrüksiyonu gelişmesi nedeniyle hipoksemi riski altındadırlar. HFO'nun ise hipoksemi eğilimini azalttığı pekçok çalışmada gösterilmiştir. Bu nedenle çalışmamızda EİB uygulaması yapılan hastalarda; özellikle solunumsal olarak risk taşıyan hastalarda kullanılan ve diğer oksijen sağlayıcılara göre birçok üstünlüğü olan bir cihaz olan HFO cihazının desatürasyon riskinin azalması üzerindeki etkinliğinin değerlendirilmesi amaçlanmıştır. Materyal-metot: Retrospektif nitelikteki çalışmamıza Ocak 2024-Eylül 2024 tarihleri arasında Kırıkkale Üniversitesi Tıp Fakültesi Anesteziyoloji ve Reanimasyon Kliniği tarafından sedasyon işlemi altında EİB yerleştirilmesi işlemi yapılan 100 hasta dahil edildi. Bu hastalardan 50 tanesi HFO kullanılan, 50 tanesi nazal kanül kullanılan hastalardan seçildi. Hastalara ait veriler hasta dosyalarından, anestezi bilgi fişlerinden, bilgisayar bilgi sisteminden geriye dönük olarak toplandı ve beşli Likert ölçeği kullanılarak elde edilen memnuniyet anket skorları incelendi. Her iki grupta yer alan hastaların demografik verileri [cinsiyet, yaş, kilo, boy, vücut kitle indeksi (VKİ), sigara kullanım öyküsü, obstrüktif uyku apne sendromu (OSAS) varlığı]; ameliyathane odasında hastanın başlangıç vital bulguları [tansiyon arteriyel, nabız, kan oksijen satürasyon değeri (SpO₂)]; işlemin 1., 5., 10., 15. dakikalarındaki vital bulguları kaydedildi. Bunlara ek olarak işlem sırasında gelişen komplikasyonlar, desatürasyon varlığı, desatürasyon süresi, maske ventilasyon ihtiyacı, maske ventilasyon süresi, derlenme süresi, hasta memnuniyeti kaydedildi. İstatistiksel analizler SPSS versiyon 26.0 paket programı kullanılarak yapıldı. Çalışmadaki istatistiksel analizlerde p değeri 0,05'in altındaki karşılaştırmalar istatistiksel olarak anlamlı kabul edildi. Bulgular: Çalışmaya 100 hasta katılmıştır. Katılımcıların yaş ortalaması 35,26±9,56; 90 (%90)'ı kadın, 10 (%10)'u erkektir. NO grubunda yer alan hastalarda HFO grubuna göre komplikasyon oranı istatistiksel olarak anlamlı farkla fazla bulunmuştur [sırasıyla 22 (%44,0) ve 11 (%22,0) hasta]. Cerrahi başlama ve bitiş süresi NO grubunda HFO grubunda göre anlamlı farkla uzun bulunmuştur [9 (4-40) ve 8 (4-17) dk] (p<0,05). Her iki grupta, gelişen komplikasyonlar değerlendirildiğinde HFO grubunda hiçbir hastada kusma, apne ve aspirasyon komplikasyonlarının gelişmediği görülmüştür. NO grubunda ise 1 (%98) hastada kusma ve 1 (%98) hastada apne görülmüştür. Apne gelişimi nedeni ile bu hastada işlem sonlandırılmıştır. NO grubunda da aspirasyon gelişen hasta olmamıştır. Desatürasyon HFO grubunda 18 (%36,0) ve NO grubunda 25 (%50,0) hastada saptanmış, desatürasyona göre iki grup arasında istatistiksel olarak anlamlı fark bulunmamakla birlikte, oranın HFO grubunda daha düşük olduğu görülmüştür (p>0,05). HFO grubundaki hastaların 36 (%73,5)'sı, NO grubundakilerin ise 23 (%46,0)'ü memnuniyet düzeylerini 'çok memnun' olarak belirtmiş ve memnuniyet düzeyinin HFO grubunda istatistiksel olarak anlamlı farkla yüksek olduğu bulnmuştur (p<0,05). Grupların 1., 5., 10. ve 15. dk vital bulgularında istatistiksel olarak anlamlı fark bulunmamıştır (p>0,05). Sonuç: Çalışmamız verileri, endoskopi sırasında uygulanan sedasyonda, pekçok yönden HFO'nun NO'dan avantajlı olduğunu göstermiştir. HFO, obez hastalarda endoskopik bir girişim olan EİB uygulaması sırasında; özellikle hipoksi ve desatürasyon başta olmak üzere komplikasyon riskini düşürmekte, hasta konforu ve memnuniyetini artırmakta, mekanik ve teknik özelliklerinden dolayı işlem sırasında cerrahın konforunu ve hızını artırmasına bağlı olarak cerrahinin başlama ve bitiş süresini kısaltmakta, hastanın anesteziden derlenme süresini kısaltmaktadır.

Özet (Çeviri)

Objective: Sedation is a term used to describe a drug-induced state of calm, rest, or drowsiness. Sedative, anxiolytic and analgesic pharmacotherapies are used in surgical and minimally invasive procedures. Endoscopic intragastric balloon (IEB) treatment, which is a temporary and minimally invasive treatment method, is currently the main choice for mild obesity. It is a suitable option for overweight and obese patients who do not respond to clinical therapy, are not candidates for surgery, or do not wish to undergo a surgical procedure. During surgical or minimally invasive procedures, oxygen is administered to the patient via slow-flow systems [flow rate <15 liters (L)/min] such as nasal cannula, simple face mask, reservoir masks, and diffuser masks; or via high-flow systems such as venturi mask and high-flow nasal cannula. Oxygen can be administered with nasal cannulas at a flow rate of 1-6 L/min. Oxygen delivered at high flows cannot increase the fraction of inspired oxygen (FiO₂) by more than 45% and drying of mucous membranes may occur, especially at flow rates higher than 4 L/min. High flow nasal oxygen (HFO); is a method in which the gas is heated, humidified and delivered through large diameter nasal cannulas; thus increasing the patient's comfort and tolerance. HFO can provide higher oxygen flow rates and more precise FiO₂ than traditional oxygen delivery systems. The gas flow rate is typically set between 30–70 L/min, allowing FiO₂ delivery ranging from 21% to 100%. In obese patients, the tendency to hypoxemia is increased due to numerous anatomical and physiological changes and increased oxygen consumption. Obese patients undergoing EIB are at risk of hypoxemia due to anatomical, physiological, and systemic differences and due to the development of upper respiratory tract obstruction during endoscopic intervention and due to the anesthetic drug administered. HFO has been shown in many studies to reduce the tendency to hypoxemia. Therefore, our study aimed to evaluate the effectiveness of the HFO device, which is a device that is used especially in patients with respiratory risks and has many advantages over other oxygen providers, on reducing the risk of desaturation in patients undergoing EIB. Materials-methods: Our retrospective study included 100 patients who underwent EIB placement under sedation by the Kırıkkale University Medical Faculty Anesthesiology and Reanimation Clinic between January 2024 and September 2024. Of these patients, 50 were selected from patients who used HFO and 50 from patients who used nasal cannula. Data belonging to the patients were collected retrospectively from patient files, anesthesia information sheets, and computer information system and satisfaction survey scores obtained using a five-point Likert scale were examined. Demographic data of the patients in both groups [gender, age, weight, height, body mass index (BMI), smoking history, presence of obstructive sleep apnea syndrome (OSAS)]; the patient's initial vital signs in the operating room [arterial blood pressure, pulse, blood oxygen saturation (Sp0₂)]; vital signs at the 1st, 5th, 10th and 15th minutes of the procedure were recorded. In addition, complications that developed during the procedure, presence of desaturation, duration of desaturation, need for mask ventilation, duration of mask ventilation, recovery time, and patient satisfaction were recorded. Statistical analyses were performed using the SPSS version 26.0 package program. In the statistical analyses in the study, comparisons with a p value below 0.05 were considered statistically significant. Results: 100 patients participated in the study. The mean age of the participants was 35.26±9.56; 90 (90%) were female and 10 (10%) were male. The complication rate was found to be statistically significantly higher in the NO group compared to the HFO group [22 (44.0%) and 11 (22.0%) patients, respectively]. The start and finish times of surgery were significantly longer in the NO group compared to the HFO group [9 (4-40) and 8 (4-17) min] (p<0.05). When the complications that developed in both groups were evaluated, it was seen that no patient in the HFO group developed vomiting, apnea and aspiration complications. In the NO group, vomiting was observed in 1 patient (98%) and apnea was observed in 1 patient (98%). The procedure was terminated in this patient due to the development of apnea. There were no patients in the NO group who developed aspiration. Desaturation was detected in 18 (36.0%) patients in the HFO group and 25 (50.0%) patients in the NO group. Although there was no statistically significant difference between the two groups in terms of desaturation, the rate was lower in the HFO group (p>0.05). 36 (73.5%) of the patients in the HFO group and 23 (46.0%) of the patients in the NO group stated their satisfaction level as 'very satisfied', and the satisfaction level was found to be statistically significantly higher in the HFO group (p<0.05). No statistically significant difference was found in the vital findings of the groups at the 1st, 5th, 10th and 15th minutes (p>0.05). Conclusions: Our study data showed that HFO is advantageous over NO in many aspects in sedation applied during endoscopy. During the application of EIB, which is an endoscopic procedure in obese patients, HFO reduces the risk of complications, especially hypoxia and desaturation; increases patient comfort and satisfaction; shortens the start and finish time of surgery due to the increase in the comfort and speed of the surgeon during the procedure due to its mechanical and technical features; and shortens the patient's recovery time from anesthesia.

Benzer Tezler

  1. Behçetli hastalarda gastrointestinal sistem tutulumu üzerine prospektif bir çalışma

    Başlık çevirisi yok

    ŞEREF EREN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    Erciyes Üniversitesi

    İç Hastalıkları Ana Bilim Dalı

    Yükleniyor...

  2. M.S. 5. yüzyıl Geç Roma dönemine ait bir erkek iskelette ankilozan spondilit

    Başlık çevirisi yok

    ZÜBEYDE ÇELİK

    Yüksek Lisans

    Türkçe

    Türkçe

    1988

    Çukurova Üniversitesi

    Anatomi Ana Bilim Dalı

    Yükleniyor...

  3. Koyunlarda döl veriminin genetik ıslahında testis özelliklerinden yararlanma olanakları

    Başlık çevirisi yok

    NEDİM KOŞUM

    Yüksek Lisans

    Türkçe

    Türkçe

    1988

    Ege Üniversitesi

    Zootekni Ana Bilim Dalı

    Yükleniyor...

  4. Gastrik kanser ve ülserlerin tanısında sitrik asit ve sodyum bikarbonattan elde edilen gaz ile çift kontrast tekniğin önemi

    Başlık çevirisi yok

    NAZİF ŞIK

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1988

    Erciyes Üniversitesi

    Radyodiagnostik Ana Bilim Dalı

    Yükleniyor...

  5. Gastrit ve peptik ülserler ile campylobacter pylori arasındaki ilişki

    Başlık çevirisi yok

    NECMİ TUNÇ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1989

    Uludağ Üniversitesi

    Mikrobiyoloji ve Enfeksiyon Hastalıkları Ana Bilim Dalı

    Yükleniyor...