Geri Dön

Bulk-Fill kompozit rezinlerin süt ve daimi dişlerdeki radyoopasitelerinin değerlendirilmesi

Evaluation of the radiopacity of Bulk-Fill composite resins in primary and permanent teeth

  1. Tez No: 989711
  2. Yazar: ZEYNEP TUĞRAN
  3. Danışmanlar: DOÇ. DR. CANAN BAYRAKTAR NAHİR
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2025
  8. Dil: Türkçe
  9. Üniversite: Tokat Gaziosmanpaşa Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Pedodonti Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu tez çalışması, farklı materyal içeriğine sahip olan altı farklı bulk-fill kompozit rezin materyalinin radyoopasite değerlerinin süt ve daimi diş mine ve dentin yapılarıyla karşılaştırmak amacıyla yapılmıştır. Bu tez çalışmasında SDR Plus Bulk-Fill Flowable, Estelite Flowable Bulk-fill, 3M Filtek Bulk-Fill Flowable Restorative, Beautifil Bulk Flowable, Xtra Fill ve Simplishade Bulk-fill kompozit rezin materyalleri incelenmiştir. Her bir materyal 1, 2 ve 4 mm kalınlıklarda hazırlanmış; süt ve daimi dişlerden elde edilen mine ve dentin örnekleri ile birlikte dijital radyografi yöntemi kullanılarak görüntülenmiştir. Radyografik görüntülerdeki ortalama gri değerler Image J yazılımı ile ölçülmüş ve alüminyum step wedge yöntemi kullanılarak mmAl cinsinden radyoopasite değerleri hesaplanmıştır. Verilerin analizi IBM SPSS v23 ile yapılmış, normal dağılıma uygunluk Shapiro-Wilk Testi ile incelenmiştir. Diş/Materyal ve kalınlıklara göre normal dağılım göstermeyen verilerin karşılaştırılmasında Robust ANOVA kullanılmış ve çoklu karşılaştırmalar Holm Düzeltmeli Robust t Testi ile incelenmiştir. Anlamlılık düzeyi p<0,05 olarak alınmıştır. Analiz sonuçları, hem materyal türünün hem de uygulama kalınlığının radyoopasite üzerinde istatistiksel olarak anlamlı etkiye sahip olduğunu göstermiştir (p<0,001). Ayrıca diş/materyal - kalınlık etkileşiminin de oldukça yüksek bir etki büyüklüğüne sahip olduğu saptanmıştır (kısmi eta kare = 0,999). Çalışma bulguları, bulk-fill kompozit rezin materyallerinin radyoopasite değerlerinin farklı uygulama kalınlığı, seçilen materyal türü ve materyal-kalınlık etkileşimine bağlı olarak değiştiğini göstermiştir. Bu doğrultuda, klinik uygulamalarda restoratif materyal seçimi yapılırken materyalin radyoopasite özelliklerinin, uygulama kalınlığı ve diş dokusuyla olan ilişkisi göz önünde bulundurulmalı; elde edilen bulguların tanısal doğruluk ve restorasyon takibi açısından yol gösterici olabileceği düşünülmektedir.

Özet (Çeviri)

This thesis aimed to compare the radiopacity values of six bulk-fill composite resin materials with different material compositions in relation to the enamel and dentin structures of primary and permanent teeth. The bulk-fill composite resins evaluated in this study were SDR Plus Bulk-Fill Flowable, Estelite Flowable Bulk-Fill, 3M Filtek Bulk-Fill Flowable Restorative, Beautifil Bulk Flowable, X-tra Fill, and Simplishade Bulk-Fill. Each material was prepared in thicknesses of 1, 2, and 4 mm and radiographed together with enamel and dentin samples obtained from primary and permanent teeth using a digital radiographic system. The mean gray values obtained from the radiographic images were measured using Image J software, and radiopacity values were calculated in terms of millimeters of aluminum (mmAl) by applying the aluminum step wedge method. Statistical analyses were performed using IBM SPSS version 23. Normality of data distribution was assessed using the Shapiro–Wilk test. For comparisons involving tooth/material types and thicknesses that did not show normal distribution, Robust ANOVA was applied, and multiple comparisons were conducted using the Holm-corrected robust t-test. The level of statistical significance was set at p < 0.05. The results demonstrated that both the type of material and the application thickness had a statistically significant effect on radiopacity (p < 0.001). In addition, the interaction between tooth/material type and thickness showed a very large effect size (partial eta squared = 0.999). The findings of this study indicate that the radiopacity values of bulk-fill composite resin materials vary depending on the applied thickness, the selected material type, and the interaction between material and thickness. In this regard, when selecting restorative materials for clinical applications, the material's radio-opacity properties, application thickness and relationship with dental tissue should be taken into consideration; it is thought that the findings obtained may be indicative in terms of diagnostic accuracy and restoration follow-up.

Benzer Tezler

  1. Liyofilize yoğurt kültürü eldesi ve muhafazası üzerine araştırmalar

    Başlık çevirisi yok

    MELEK FOTOCAN

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Ege Üniversitesi

    Gıda Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  2. Sapan gözlemlerin istatistiksel olarak değerlendirilmesi üzerine bir çalışma

    Literature survey for detecting outlying observtions in samples

    M.İZZET ÇİÇEK

    Yüksek Lisans

    Türkçe

    Türkçe

    1984

    Ege Üniversitesi

    Bilgisayar Bilimleri ve Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  3. Söğüt (GD Bilecik) yöresindeki mesozoyik yaşlı tortul istifinin stratigrafisi ve sedimantolojik incelenmesi

    Stratigraphical and sedimentological investigation of the mesozoic sedimentary units of Söğüt area (se Bilecik)

    ERDOĞAN TEKİN

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Ankara Üniversitesi

    Jeoloji Mühendisliği Ana Bilim Dalı

    Yükleniyor...