Geri Dön

Glass ıonomer cement kullanılarak yapılan işitme rekonstrüksiyonu cerrahisinin uzun dönem odyolojik sonuçlara etkisi: Retrospektif bir analiz

The effect of hearing reconstruction surgery using glass ionomer cement on long-term audiological outcomes: A retrospective analysis

  1. Tez No: 998931
  2. Yazar: ARDA ER
  3. Danışmanlar: DOÇ. DR. MUHAMMED DAĞKIRAN
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Kulak Burun ve Boğaz, Otorhinolaryngology (Ear-Nose-Throat)
  6. Anahtar Kelimeler: Kronik Otitis Media, Hava-kemik Aralığı, Glass İyonemer Cement, Geç Postoperatif, Chronic Otitis Media, Air-bone Gap, Glass İonomer Cement, Late Postoperative
  7. Yıl: 2026
  8. Dil: Türkçe
  9. Üniversite: Çukurova Üniversitesi
  10. Enstitü: Tıp Fakültesi
  11. Ana Bilim Dalı: Kulak Burun Boğaz Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Bu çalışmanın amacı işitme rekonstrüksiyon cerrahisinde glass ionemer cement (GIC) kullanılan hastalarda preoperatif, erken postoperatif ve geç postoperatif işitme sonuçlarının karşılaştırılarak uzun dönemdeki fonksiyonel sonuçlarının incelenmesidir. Gereç ve Yöntemler: Bu retrospektif çalışmaya, kronik otitis media ve kulak zarı intakt olmasına rağmen iletim tipi işitme kaybı nedeniyle ossiküler rekonstrüksiyon uygulanmış hastalar dahil edildi. Hastaların 2-5 yıl, 5-10 yıl ve 10 yıl üzeri takipli gruplar halinde preoperatif, erken postoperatif ve geç postoperatif sonuçları değerlendirildi. Bulgular: Tüm takip gruplarında (2–5 yıl, 5–10 yıl ve ≥10 yıl) erken postoperatif dönemde (3-12 ay) hava yolu işitme eşikleri ve hava–kemik aralıklarında preoperatif döneme kıyasla istatistiksel olarak anlamlı iyileşme saptandı. 5-10 yıl hastaların erken postoperatif dönemdeki hava kemik aralığı 21,18±12,51 dB iken geç postoperatif dönemde (ortalama 77,3 ay) 22,58±13,56 dB olarak raporlanmış ve hava kemik aralığında anlamlı bozulma izlenmemiştir (p:0,439). 10 yıl üzeri hastaların erken postoperatif hava kemik aralığı 18,93±9,82 dB iken geç postoperatif dönemde 24±11,86 dB olarak raporlanmış ve anlamlı olarak bozulma izlenmiştir (p:0.030). Sonuç: GIC kullanılarak yapılan ossiküler rekonstrüksiyonlar, erken dönemde belirgin işitsel kazanım sağlamakta ve bu kazanım uzun dönem takiplerde büyük ölçüde korunmaktadır. Zamanla sınırlı değişiklikler gözlenmesine rağmen GIC'ın uzun vadede (5-10 yıl ve 10 yıl üzeri) kabul edilebilir bir rekonstrüktif materyal olduğunu düşündürmektedir.

Özet (Çeviri)

Aim: The aim of this study is to evaluate the long-term functional outcomes by comparing preoperative, early postoperative, and late postoperative hearing results in patients who underwent hearing reconstruction surgery using glass ionomer cement (GIC). Materials and Methods: This retrospective study included patients who underwent ossicular reconstruction due to conductive hearing loss associated with chronic otitis media despite an intact tympanic membrane. Preoperative, early postoperative, and late postoperative outcomes were evaluated in patient groups stratified according to follow-up duration as 2–5 years, 5–10 years, and more than 10 years. Results: Across all follow-up groups (2–5 years, 5–10 years, and ≥10 years), a statistically significant improvement in air-conduction hearing thresholds and air–bone gaps was observed in the early postoperative period (3–12 months) compared with the preoperative period. In the 5–10-year follow-up group, the early postoperative air–bone gap was 21.18 ± 12.51 dB, while the late postoperative value (mean follow-up of 77.3 months) was 22.58 ± 13.56 dB, with no statistically significant deterioration in the air– bone gap (p = 0.439). In contrast, in patients with a follow-up duration of more than 10 years, the early postoperative air–bone gap was 18.93 ± 9.82 dB and increased to 24 ± 11.86 dB in the late postoperative period, indicating a statistically significant deterioration (p = 0.030). Conclusion: Ossicular reconstructions performed using glass ionomer cement (GIC) provide a marked improvement in hearing outcomes in the early postoperative period, and this gain is largely maintained during long-term follow-up. Although limited changes may occur over time, the overall findings suggest that GIC remains an acceptable reconstructive material in the long term, including follow-up durations of 5–10 years and more than 10 years.

Benzer Tezler

  1. Sonbahar sera yetiştiriciliğine uygun hıyar çeşit seçimi

    Selecting a cucumber variety suitable for glasshouse production in Autumn

    MESUT OKTAY

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Yükleniyor...

  2. Plazma arkı eldesi ve yüzey bölgesi modifikasyonunda kullanılabilirliği

    Başlık çevirisi yok

    ÖZKAN ÖZİPEKLİLER

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Uludağ Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  3. Hıyar turşularında sorbik asitin yüzeyde zar oluşumuna etkisi üzerinde bir araştırma

    Başlık çevirisi yok

    TÜLAY DALGIÇ

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Gıda Bilimi ve Teknolojisi Ana Bilim Dalı

    Yükleniyor...

  4. Nar konsantresinin dondurularak ve kimyasal yöntemlerle saklanması sırasında meydana gelen değişmeler üzerine bir araştırma

    Başlık çevirisi yok

    İLHAN BODUR

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Tarım Ürünleri Teknolojisi Ana Bilim Dalı

    Yükleniyor...

  5. Liyofilize yoğurt kültürü eldesi ve muhafazası üzerine araştırmalar

    Başlık çevirisi yok

    MELEK FOTOCAN

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Ege Üniversitesi

    Gıda Mühendisliği Ana Bilim Dalı

    Yükleniyor...