Bir boru içerisine cidardan ayrık olarak yerleştirilmiş çeşitli tipteki şerit elemanların ısı transferi iyileştirmesine etkisinin deneysel olarak incelenmesi
Experimental investigation of heat transfer enhancement in a tube with various types of twisted tapes installed separately from the tube wall
- Tez No: 1002278
- Danışmanlar: PROF. DR. VEYSEL ÖZCEYHAN
- Tez Türü: Doktora
- Konular: Makine Mühendisliği, Mechanical Engineering
- Anahtar Kelimeler: Boru akışı, Isı geçişi katsayısı, Sürtünme katsayısı, Çelik şeritler, Pipe flow, Heat transfer coefficient, Friction coefficient, Steel bands
- Yıl: 2026
- Dil: Türkçe
- Üniversite: Erciyes Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
- Bilim Dalı: Makine Mühendisliği Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
Bu çalışmada, test boru içerisine iç yüzeyle temas etmeyecek şekilde yerleştirilen bükülmüş şeritlerin ısı transferi ve basınç düşümü üzerindeki etkileri deneysel olarak analiz edilmiştir. Beş farklı hatve oranı (y/d= 2, 2.5, 3, 3,5 ve 4) ve dört farklı açıklık oranı (c/d = 0.0178, 0.0357, 0.0535 ve 0.0714) kullanılarak toplam 20 farklı şerit kombinasyonu, 60° hücum açısına sahip trapez kanatlar kullanılarak test edilmiştir. Reynolds sayısının 4587 ile 24.979 aralığında değiştiği ve çalışma akışkanı olarak havanın kullanıldığı deneylerde elde edilen veriler, bükülmüş şerit kullanımının boş boruya oranla hem ısı transferini hem de basınç düşümünü artırdığını, özellikle hatve ve açıklık oranları azaldıkça Nusselt sayısı, sürtünme katsayısı ve net iyileşme oranının yükseldiğini ortaya koymuştur. Çalışmanın bulguları arasında, en yüksek net iyileşme oranı 1.524, y/d = 2 ve c/d = 0,0178 oranlarında ve Reynolds sayısı 4958'de kaydedilmiştir. Sonuç olarak, hatve oranının açıklık oranına kıyasla ısı transferi ve basınç düşümü üzerinde daha baskın bir etki oluşturduğu; ayrıca şeritlerin boru iç yüzeyinden ayrık yerleştirilmesinin kir birikmesini azaltarak ısı geçiş performansını olumlu yönde etkileyebileceği ortaya konmuştur
Özet (Çeviri)
In this study, the effects of twisted tapes placed inside the test tube without contacting the inner surface on heat transfer and pressure drop were experimentally analyzed. A total of 20 different tape combinations, using five different pitch ratios (y/D= 2, 2.5, 3, 3,5 ve 4) and four different clearance ratios (c/D = 0.0178, 0.0357, 0.0535 ve 0.0714), were tested using trapezoidal wings with a 60° angle of attack. Data obtained from experiments, where the Reynolds number ranged from 4587 to 24,979 and air was used as the working fluid, revealed that the use of twisted tapes increased both heat transfer and pressure drop compared to a plain tube, and that the Nusselt number, friction factor, and overall performance enhancement ratio increased as the pitch and clearance ratios decreased. Among the findings of the study, the highest overall performance enhancement ratio was recorded at 1.524, y/D = 2, and c/D = 0.0178, with a Reynolds number of 4958. As a result, it has been demonstrated that the pitch ratio has a more dominant effect on heat transfer and pressure drop compared to the clearance ratio; furthermore, it has been shown that placing the strips separately from the inner surface of the pipe can reduce dirt accumulation and positively affect heat transfer performance.
Benzer Tezler
- Ovulasyon indüksiyonu tedavisinde folliküler gelişimin ultrasonografik takibi
Başlık çevirisi yok
MERİH BAYRAM
- Bir ilaç fabrikasında personel gereksinmesinin belirmesi seçilmesi ve elde tutulmasına yönelik bir uygulama çalışması
Başlık çevirisi yok
EMİNE BOZBAĞ
Yüksek Lisans
Türkçe
1989
İstanbul ÜniversitesiÇalışma Ekonomisi ve Endüstri İlişkileri Ana Bilim Dalı
Yükleniyor...
- İzmir'de bazı yolların kapatılarak yaya bölgeleri oluşturma da kent peyzajını geliştirme açısından yeniden planlanması üzerinde araştırmalar
Başlık çevirisi yok
BAHAR TÜRKYILMAZ
- Atherosklerotik kalp hastalıklarında risk faktörleri
Risk factors in the coronary artery disease
MURAT SUHER