Klinik iş akışının protez kaide üretimine etkisinin analizi: Geleneksel üretim ve dijital üretimin karşılaştırılması
Influence of clinical workflow on complete denture base fabrication: Conventional vs. digital methods
- Tez No: 1002431
- Danışmanlar: PROF. DR. BİLGE GÖKÇEN RÖHLİG
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: CAD/CAM, dijital ölçü, tam protez, doku uyumu, eklemeli üretim, CAD/CAM, complete denture, denture fit, intraoral scanning
- Yıl: 2026
- Dil: Türkçe
- Üniversite: İstanbul Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
- Bilim Dalı: Protetik Diş Tedavisi Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
Tam dişsiz hastalarda protetik tedavinin başarısı, protez kaidesinin destek dokularla olan uyumuna bağlıdır ve bu uyum, kullanılan ölçü alma ve üretim yöntemlerinden doğrudan etkilenmektedir. Tam protez üretiminde geleneksel yöntemler uzun yıllardır öngörülebilir ve klinik olarak güvenilir sonuçlar sunarken, dijital teknolojilerdeki ilerlemelere paralel olarak tam dijital ve hibrit iş akışları da klinik uygulamalarda giderek daha yaygın biçimde kullanılmaya başlanmıştır. Bununla birlikte, bu yaklaşımların doku uyumu açısından karşılaştırmalı klinik performansına ilişkin veriler sınırlıdır. Bu çalışmada geleneksel, tam dijital ve iki farklı hibrit iş akışıyla üretilen üst çene tam protez kaidelerinin doku uyumlarının karşılaştırılması amaçlanmıştır. Çalışmaya tam protez tedavisi planlanan 13 tam dişsiz birey dahil edilmiş ve her hasta için dört farklı üretim yaklaşımıyla protez kaidesi hazırlanmıştır. Geleneksel yöntemde fonksiyonel ölçü ve ısı ile polimerize rezin kullanılırken, tam dijital yaklaşımda ağız içi tarama, bilgisayar destekli tasarım ve üç boyutlu baskı tekniklerinden yararlanılmış; hibrit yaklaşımlarda ise dijital ve geleneksel basamaklar birlikte uygulanmıştır. Üretilen kaidelerin dokuya bakan yüzeyleri, çalışmanın referans modeli olarak kabul edilen ve geleneksel yöntemle elde edilen ana model ile, önceden belirlenen 22 nokta ve altı anatomik bölgede çakıştırılmış; genel ve bölgesel sapma değerleri hesaplanmıştır. Ayrıca, ağız içi taramada tanımlanan anatomik referans bölgelerinin tüm hastalarda eksiksiz olarak saptandığı belirlenmiştir. Bulgular, en düşük genel sapmanın geleneksel yöntemde elde edildiğini, buna yakın değerlerin ise erken hibrit yaklaşımda gözlendiğini; tam dijital ve geç hibrit yöntemlerde daha yüksek sapmalar bulunduğunu göstermiştir. Altı anatomik bölge bazında gerçekleştirilen bölgesel analizde, posterior palatal hat alanında gruplar arasında istatistiksel olarak anlamlı bir farklılık saptanmamışken, diğer bölgelerde gruplar arasında anlamlı farklılıklar belirlenmiştir (p < 0.05). Sonuç olarak hibrit iş akışlarının klinik açıdan uygulanabilir bir alternatif sunduğu, tam dijital üretim süreçlerinin ise doku uyumu bakımından geliştirilmesi gerektiği belirlenmiştir.
Özet (Çeviri)
Predictable prosthetic rehabilitation in edentulous patients largely depends on denture base adaptation to the supporting tissues, which is directly influenced by impression and fabrication techniques. In complete denture fabrication, conventional workflows have long provided predictable and clinically reliable outcomes. Parallel to advancements in digital technologies, fully digital and hybrid workflows have increasingly been adopted in routine clinical practice. Nevertheless, comparative clinical evidence regarding their performance in terms of fit accuracy remains limited. This study evaluated the fit accuracy of maxillary complete denture bases fabricated using conventional, fully digital, and two hybrid clinical workflows. Thirteen completely edentulous patients were included, and four denture bases were fabricated for each patient using different fabrication protocols. The conventional approach employed functional impressions and heat-polymerized resin, whereas the fully digital workflow relied on intraoral scanning, computer-aided design, and additive manufacturing. Hybrid workflows combined digital and conventional procedures at different treatment stages. The intaglio surfaces of all denture bases were compared with the master cast obtained from the conventional workflow as the reference. Deviation values were calculated at 22 predefined landmarks within six anatomical regions to assess overall and regional fit. In addition, all predefined anatomical reference regions were consistently identifiable in the intraoral datasets of all patients. The smallest overall deviation was observed in the conventional group, followed by comparable values in the early hybrid workflow, whereas the fully digital and late hybrid approaches showed greater discrepancies. In the regional analysis performed across six anatomical areas, no statistically significant intergroup difference was detected in the posterior palatal seal region, whereas significant differences were observed among groups in the remaining regions (p < 0.05). Hybrid approaches demonstrated clinically acceptable fit, while further optimization of fully digital denture fabrication is required to enhance tissue conformity.
Benzer Tezler
- Doğuştan kalça çıkıklı hastalarda kalça patolojilerinin bilgisayarlı tomografi ile değerlendirilmesi
Başlık çevirisi yok
NECDET ŞÜKRÜ ALTUN
- Türkiye'de serebral hareket bozukluklarının etiyolojisi epidemiyolojisi ve bazı klinik özellikleri
Başlık çevirisi yok
AŞER BENSUSAN
Tıpta Uzmanlık
Türkçe
1986
İstanbul ÜniversitesiÇocuk Sağlığı ve Hastalıkları Ana Bilim Dalı
Yükleniyor...
- Pre-eklampsi ve eklampsi vakalarında immünoglobülin düzeylerinin değerlendirilmesi (Klinik ve immünobiolojik araştırma)
Examination des valeurs d'immunoglobulines en cas de la toxemie gravidique
M. MURAT SEMİZ
- Çocuklarda akut stres hiperglisemisinde hormonal değişikliklerin ve kısa süreli prognozun incelenmesi
Başlık çevirisi yok
AYGÜN DİNDAR
Tıpta Uzmanlık
Türkçe
1987
İstanbul ÜniversitesiÇocuk Sağlığı ve Hastalıkları Hemşireliği Ana Bilim Dalı
Yükleniyor...