Geri Dön

Tam ağız rehabilitasyonunda farklı interoklüzal mesafeler ve referans geçicilerinin dijital ölçü doğruluğu üzerine etkisi

The effect of different interocclusal distances and reference temporaries on digital impression accuracy in full-mouth rehabilitation

  1. Tez No: 1012915
  2. Yazar: ASLI ÇİFTÇİ
  3. Danışmanlar: DOÇ. DR. EMİNE BEGÜM BÜYÜKERKMEN
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Ağız içi tarayıcı, dijital interoklüzal kayıt, interoklüzal mesafe, RMS, tam ağız rehabilitasyonu, Intraoral scanner, digital interocclusal record, interocclusal distance, RMS, full-mouth rehabilitation, temporary restoration
  7. Yıl: 2026
  8. Dil: Türkçe
  9. Üniversite: Necmettin Erbakan Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

ÖZET Necmettin Erbakan Üniversitesi, Diş Hekimliği Fakültesi Protetik Diş Tedavisi Anabilim Dalı Uzmanlık Tezi TAM AĞIZ REHABİLİTASYONUNDA FARKLI İNTEROKLÜZAL MESAFELER VE REFERANS GEÇİCİLERİNİN DİJİTAL ÖLÇÜ DOĞRULUĞU ÜZERİNE ETKİSİ Aslı ÇİFTÇİ Konya-2026 Amaç: Bu çalışmanın amacı, tam ağız preparasyonu sonrasında farklı interoklüzal mesafeler ve referans geçici restorasyon kombinasyonlarının, farklı ağız içi tarayıcılar kullanılarak elde edilen dijital interoklüzal kayıtların doğruluğu üzerindeki etkisini değerlendirmektir. Gereç ve Yöntem: Bu in vitro çalışmada, Frasaco alt ve üst çene modelleri yarı ayarlanabilir artikülatöre aktarılmış ve standart protetik preparasyonlar gerçekleştirilmiştir. Üç farklı interoklüzal mesafe (0 mm, 2 mm ve 4 mm) ve dört farklı referans geçici restorasyon kombinasyonu oluşturulmuştur. Dijital kapanış kayıtları iki farklı ağız içi tarayıcı (iTero ve Primescan) kullanılarak elde edilmiştir. Her kombinasyon için 12 tekrar yapılmış ve toplam 288 dijital kayıt analiz edilmiştir. Masaüstü tarayıcı ile elde edilen referans STL modelleriyle karşılaştırma yapılarak geometrik sapmalar RMS (root mean square) değerleri üzerinden değerlendirilmiştir. İstatistiksel analizlerde Robust ANOVA ve Holm düzeltmeli çoklu karşılaştırmalar kullanılmıştır (α = 0,05). Bulgular: Tarayıcı tipi ve interoklüzal mesafenin RMS değerleri üzerinde istatistiksel olarak anlamlı etkisi olduğu saptanmıştır (p < 0,001). Primescan tarayıcısı, iTero'ya kıyasla daha düşük RMS değerleri göstermiştir. Primescan'da en düşük RMS değerleri 4 mm interoklüzal mesafede, iTero'da ise 2 mm mesafede elde edilmiştir. Referans geçici restorasyon bölgeleri arasında RMS değerleri açısından istatistiksel olarak anlamlı fark bulunmamıştır (p > 0,05). Sonuç: Tam ağız rehabilitasyonlarında dijital interoklüzal kayıt doğruluğu, esas olarak kullanılan ağız içi tarayıcı ve interoklüzal mesafeye bağlıdır. Referans geçici restorasyon bölgesi, yeterli geometrik veri sağlandığı sürece ölçü doğruluğu üzerinde ikincil bir etkiye sahiptir. Klinik uygulamalarda, tarayıcıya özgü optimal interoklüzal mesafe stratejilerinin benimsenmesi dijital ölçü doğruluğunu artıracaktır.

Özet (Çeviri)

ABSTRACT Necmettin Erbakan University, Faculty of Dentistry Department of Prosthodontic Specialization Thesis in Dentistry THE EFFECT OF DIFFERENT INTEROCCLUSAL DISTANCES AND REFERENCE TEMPORARIES ON DIGITAL IMPRESSION ACCURACY IN FULL-MOUTH REHABILITATION Aslı ÇİFTÇİ Konya-2026 Objective: The aim of this study was to evaluate the effect of different interocclusal distances and reference temporary restoration combinations, after full-mouth preparation, on the accuracy of digital interocclusal records obtained using different intraoral scanners. Materials and Methods: In this in vitro study, Frasaco maxillary and mandibular models were mounted on a semi-adjustable articulator, and standardized prosthetic preparations were performed. Three different interocclusal distances (0 mm, 2 mm, and 4 mm) and four different reference temporary restoration combinations were established. Digital interocclusal records were obtained using two different intraoral scanners (iTero and Primescan). Twelve repetitions were performed for each combination, yielding a total of 288 digital records. Geometric deviations were evaluated by comparing the datasets with reference STL models obtained from a desktop scanner, and deviations were quantified using root mean square (RMS) values. Robust ANOVA and Holm-adjusted multiple comparisons were applied for statistical analysis (α = 0.05). Results: Scanner type and interocclusal distance had a statistically significant effect on RMS values (p < 0.001). The Primescan scanner demonstrated lower RMS values compared with iTero. For Primescan, the lowest RMS values were observed at a 4-mm interocclusal distance, whereas for iTero, the lowest RMS values were obtained at 2 mm. No statistically significant differences in RMS values were found among the reference temporary restoration regions (p > 0.05). Conclusion: The accuracy of digital interocclusal records in full-mouth rehabilitation is primarily influenced by the intraoral scanner used and the interocclusal distance. The reference temporary restoration region has a secondary effect on measurement accuracy, provided that sufficient geometric data are available. Adopting scanner-specific optimal interocclusal distance strategies in clinical practice may enhance digital recording accuracy.

Benzer Tezler

  1. Tam dişsiz olguların implant ile rehabilitasyonunda farklı ölçü tekniklerinin hassasiyetlerinin değerlendirilmesi

    Evaluation of the accuracy of different impression techniques in implant rehabilitation of edentulous cases

    MEHMET HAKAN KÜLAHCI

    Doktora

    Türkçe

    Türkçe

    2022

    Diş Hekimliğiİstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. GÜLÜMSER EVLİOĞLU

  2. Evaluation of biomechanical and thermal properties of zygomatic implants and subperiosteal implants in rehabilitation of atrophic total edentulous maxilla: A finite element analysis

    Atrofik total dişsiz maksilla rehabilitasyonunda kullanılan zigomatik implantların ve subperiosteal implantların biyomekanik ve termal özelliklerinin sonlu eleman analizi yöntemi ile değerlendirilmesi

    SAİT EMRE KALAYCIOĞLU

    Doktora

    İngilizce

    İngilizce

    2025

    Diş HekimliğiYeditepe Üniversitesi

    Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı

    PROF. DR. CEYDA ÖZÇAKIR TOMRUK

  3. Dişsiz mandibulada dental implant yiv adımının ve şeklinin stres dağılımına etkilerinin üç boyutlu sonlu elemanlar analizi ile değerlendirilmesi

    The determination of thread pitch and thread shape on stresses in edentulous mandible by three dimensional finite element analysis

    GÖKTUĞ SİNA OKKAN

    Doktora

    Türkçe

    Türkçe

    2015

    Diş HekimliğiGazi Üniversitesi

    Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı

    PROF. DR. NUR MOLLAOĞLU

  4. Atrofik edentülöz maksillada quad zygoma, M4, transnazal ve vomer implant konfigurasyonlarının sonlu eleman yöntemi ile karşılaştırmalı biyomekanik analizi

    Comparative biomechanical analysis of quad zygoma, M4, transnasal, and vomer implant configurations in the atrophic edentulous maxilla using the finite element method

    AHMET YAY

    Diş Hekimliği Uzmanlık

    İngilizce

    İngilizce

    2026

    Diş HekimliğiKaradeniz Teknik Üniversitesi

    Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı

    DOÇ. DR. ONUR YILMAZ

  5. Total dişsizlik olgularında bilateral balanslı oklüzyona protrüziv kondil yolu eğiminin etkisinin in vivo olarak değerlendirilmesi

    In vivo evaluation of the effect of protrusive condylar inclination on bilateral balanced occlusion in total edentulous cases

    TANER TÜRKAY

    Doktora

    Türkçe

    Türkçe

    2023

    Diş HekimliğiSelçuk Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. İSA YÖNDEM